Bor Antolic

Dr. Bor Antolic

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
PFPiotr Futyma
Piotr Futyma
ASArian Sultan
Arian Sultan
ŁZŁukasz Piotr Zarębski
Łukasz Piotr Zarębski
DIDr. Med. Guram Imnadze
Dr. Med. Guram Imnadze
VMVera Maslova
Vera Maslova
JCJulian K R Chun
Julian K R Chun
Advanced ablation strategies are needed to treat ventricular tachycardia (VT) and premature ventricular complexes (PVC) refractory to standard unipolar radiofrequency ablation (Uni-RFA). Bipolar radiofrequency catheter ablation (Bi-RFA) has emerged as a treatment option for refractory VT and PVC. Multicentre registry data on the use of Bi-RFA in the setting of refractory VT and PVC are lacking. The aim of this Bi-RFA registry is to determine its real-world safety, feasibility, and efficacy in patients with refractory VT/PVC. Consecutive patients undergoing Bi-RFA at 16 European centres for recurring VT/PVC after at least one standard Uni-RFA were included. Second ablation catheter was used instead of a dispersive patch and was positioned at the opposite site of the ablation target. Between March 2021 and August 2024, 91 patients underwent 94 Bi-RFA procedures (74 males, age 62 ± 13, and prior Uni-RFA range 1–8). Indications were recurrence of PVC (n = 56), VT (n = 20), electrical storm (n = 13), or PVC-triggered ventricular fibrillation (n = 2). Procedural time was 160 ± 73 min, Bi-RFA time 426 ± 286 s, and mean Uni-RFA time 819 ± 697 s. Elimination of clinical VT/PVC was achieved in 67 (74%) patients and suppression of VT/PVC in a further 10 (11%) patients. In the remaining 14 patients (15%), no effect on VT/PVC was observed. Three major complications occurred: coronary artery occlusion, atrioventricular block, and arteriovenous fistula. Follow-up lasted 7 ± 8 months. Nineteen patients (61%) remained VT free. ≥80% PVC burden reduction was achieved in 45 (78%). These real-world registry data indicate that Bi-RFA appears safe, is feasible, and is effective in the majority of patients with VT/PVC.

6 June 2016 in Wiener klinische Wochenschrift
Verified
Journal Article
Closed access
PDF file
BABor Antolic
Bor Antolic
APAndrej Pernat
Andrej Pernat
MCMarta Cvijić
Marta Cvijić
DŽDavid Žižek
David Žižek
MJMatevž Jan
Matevž Jan
MŠMatjaž Šinkovec
Matjaž Šinkovec

24 April 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
DŽDavid Žižek
David Žižek
MMMiha Mrak
Miha Mrak
MJMatevž Jan
Matevž Jan
AMAnja Zupan Mežnar
Anja Zupan Mežnar
MIMaja Ivanovski
Maja Ivanovski
MŠMatjaž Šinkovec
Matjaž Šinkovec
Primary prevention patients with ischaemic cardiomyopathy and chronic total occlusion of an infarct-related coronary artery (CTO) are at a particularly high risk of implantable cardioverter-defibrillator (ICD) therapy occurrence. The trial was designed to evaluate the efficacy of preventive CTO-related substrate ablation strategy in ischaemic cardiomyopathy patients undergoing primary prevention ICD implantation. The PREVENTIVE VT study was a prospective, multicentre, randomized trial including ischaemic patients with ejection fraction ≤40%, no documented ventricular arrhythmias (VAs), and evidence of scar related to the coronary CTO. Patients were randomly assigned 1:1 to a preventive substrate ablation before ICD implantation or standard therapy with ICD implantation only. The primary outcome was a composite of appropriate ICD therapy or unplanned hospitalization for VAs. Secondary outcomes included the primary outcome’s components, the incidence of appropriate ICD therapies, cardiac hospitalization, electrical storm, and cardiovascular (CV) mortality. Sixty patients were included in the study. During the mean follow-up of 44.7 ± 20.7 months, the primary outcome occurred in 5 (16.7%) patients undergoing preventive substrate ablation and in 13 (43.3%) patients receiving only ICD [hazard ratio (HR): 0.33; 95% confidence interval (CI): 0.12–0.94; P = 0.037]. Patients in the preventive ablation group also had fewer appropriate ICD therapies (P = 0.039) and the electrical storms (Log-rank: P = 0.01). While preventive ablation also reduced cardiac hospitalizations (P = 0.006), it had no significant impact on CV mortality (P = 0.151). Preventive ablation of the coronary CTO-related substrate in patients undergoing primary ICD implantation is associated with the reduced risk of appropriate ICD therapy or unplanned hospitalization due to VAs. Preventive ablation of coronary total occlusion-related substrate at the time of primary prevention defibrillator implantation is associated with a reduced risk of appropriate defibrillator therapy or unplanned hospitalization due to ventricular arrhythmias.

17 February 2017 in EP Europace
Verified
Journal Article
Closed access
PDF file
TKTine Prolič Kalinšek
Tine Prolič Kalinšek
MJMatevž Jan
Matevž Jan
KRKatja Rupar
Katja Rupar
LRLena Ražen
Lena Ražen
BABor Antolic
Bor Antolic
DŽDavid Žižek
David Žižek
A 22-year-old woman in the 21st week of her first pregnancy without the history of heart disease was admitted to our department for electrophysiology study because of the documented symptomatic narrow QRS tachycardia. To prevent foetal X-ray exposure, three-dimensional (3D) electroanatomic mapping (EAM) system EnSite/NavX (St. Jude Medical) was used (Figure 1A). During the placement of catheters, we recorded a spontaneous induction of the orthodromic atrioventricular re-entrant tachycardia (AVRT) with the first atrial activation in the distal coronary sinus (Figure 1B), indicating the presence of a left accessory pathway. Transseptal puncture was performed with the aid of intracardiac echocardiography and without fluoroscopy. Radiofrequency ablation in the area of the earliest left atrial activation terminated the AVRT. Figure 1A shows a partial 3D EAM of the...

10 July 2021 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
BABor Antolic
Bor Antolic
NKNina Kajdič
Nina Kajdič
MVMojca Vrbajnščak
Mojca Vrbajnščak
MJMatevž Jan
Matevž Jan
DŽDavid Žižek
David Žižek

20 April 2026 in European Heart Journal
Verified
Journal Article
Open access
LPL H G van der Pol
L H G van der Pol
Bartłomiej TomasikBartłomiej Tomasik
Bartłomiej Tomasik
WHWiert F Hoeksema
Wiert F Hoeksema
SMStefano Mandija
Stefano Mandija
MMMarcin Miszczyk
Marcin Miszczyk
MFM F Fast
M F Fast
Background and Aims: Stereotactic arrhythmia radioablation (STAR) is increasingly used for refractory ventricular tachycardia (VT), yet prospective multicentre outcome data remain limited. Here, the planned interim analysis of the prospective Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) registry is reported. Methods: STOPSTORM is a European prospective, international, multicentre registry of patients treated with STAR. The primary efficacy endpoint was the change in sustained VT episode burden comparing the 6 months before versus the 6 months after STAR. The primary safety endpoint was the occurrence of serious adverse events (SAEs) adjudicated as possibly or probably treatment-related. Overall survival was assessed using time-to-event methods. Results: Across 28 centres, 193 patients were included (mean age 68±9 years; 88% male; 53% non-ischaemic cardiomyopathy). Median follow-up was 19 months. Among 107 evaluable patients with ≥6-month follow-up, the median VT episode burden was reduced by 80% after STAR. Among patients surviving ≥6 months, 72% were free from implantable cardioverter-defibrillator (ICD) shock. In the full cohort, 12 SAEs were adjudicated as possibly or probably treatment-related, including pericardial effusion, coronary events, and early post-treatment ventricular arrhythmia. Overall survival probability was 77% at 12 months. Conclusions: In the largest prospective multicentre cohort reported to date, STAR was associated with a substantial reduction in VT burden and ICD shocks, with a low frequency of possibly or probably treatment-related SAEs.