Nondestructive controllable grouting is a novel method for the accurate, reliable, and nondestructive lifting of buildings. In this method, the grouting construction is divided into several stages. First, a shallow soil layer is gradually filled and compacted by grouting, and the deep soil is reinforced by grouting until a radial compression force is generated. Subsequently, fracture grouting is performed in the middle of the reinforcement area, which generates a lifting force and resulting in the uplift of the building. Surface deformation monitoring is used during the entire uplifting process to control the amount of uplift. This method has been verified through the construction of a residential building, and the results show that nondestructive controllable grouting can effectively solve the problem of building deflection. At the same time, it avoids the problem of excessive lifting or secondary settlement that may occur in traditional grouting reinforcement. This study is expected to have considerable value as a reference for the construction of similar projects.
Although grouting technology has been widely applied for lifting and rectifying tilted structures, theoretical research remains underdeveloped and lags behind the practical demands of engineering applications. In this study, a self-developed experimental setup was utilized to conduct model tests on the lifting and rectification of a raft foundation in saturated silty clay. The evolution patterns of ground surface displacement, excess pore water pressure, and foundation-additional pressure induced by grouting were systematically analyzed. Furthermore, the influence of grouting depth and injection rate on surface displacement, excess pore water pressure, foundation-additional pressure, and grouting parameters (grout volume and pressure) was investigated. The key findings are summarized as follows: The grouting efficiency (η) ranged between 0.72 and 0.81. A power-exponential dual-function model was proposed to quantify the spatiotemporal evolution of excess pore water pressure, achieving a distance–decay power function with R2 > 0.89 and a time-dependent dissipation exponential function with > 0.94. The maximum surface uplift displacement decreased by 20.6% and 8.9% with increasing grouting rates, respectively. The dissipation time of excess pore water pressure exhibited a negative correlation with the grouting rate, and grouting efficiency declined as excess pore water pressure dissipated. The maximum foundation-additional pressure occurred directly above the grouting center and gradually diminished as the horizontal distance from the grouting location increased. Variations in surface displacement, excess pore water pressure, and additional base pressure induced by grouting were systematically analyzed.