Wei Tech Ang

Prof. Dr. Wei Tech Ang

Rehabilitation Research Institute of Singapore, Nanyang Technological University, Singapore, Singapore

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2011 in Sensors
Verified
Journal Article
Open access
PDF file
Kalyana Chakravarthy VeluvoluKalyana Chakravarthy Veluvolu
Kalyana Chakravarthy Veluvolu
WAWei Tech Ang
Wei Tech Ang
Accurate filtering of physiological tremor is extremely important in robotics assisted surgical instruments and procedures. This paper focuses on developing single stage robust algorithms for accurate tremor filtering with accelerometers for real-time applications. Existing methods rely on estimating the tremor under the assumption that it has a single dominant frequency. Our time-frequency analysis on physiological tremor data revealed that tremor contains multiple dominant frequencies over the entire duration rather than a single dominant frequency. In this paper, the existing methods for tremor filtering are reviewed and two improved algorithms are presented. A comparative study is conducted on all the estimation methods with tremor data from microsurgeons and novice subjects under different conditions. Our results showed that the new improved algorithms performed better than the existing algorithms for tremor estimation. A procedure to separate the intended motion/drift from the tremor component is formulated.

14 April 2009 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
UTU-Xuan Tan
U-Xuan Tan
WLWin Tun Latt
Win Tun Latt
CSCheng Yap Shee
Cheng Yap Shee
CRCameron N. Riviere
Cameron N. Riviere
WAWei Tech Ang
Wei Tech Ang
Piezoelectric, magnetostrictive, and shape memory alloy actuators are gaining importance in high-frequency precision applications constrained by space. Their intrinsic hysteretic behavior makes control difficult. The Prandtl-Ishlinskii (PI) operator can model hysteresis well, albeit a major inadequacy: the inverse operator does not exist when the hysteretic curve gradient is not positive definite, i.e., ill condition occurs when slope is negative. An inevitable tradeoff between modeling accuracy and inversion stability exists. The hysteretic modeling improves with increasing number of play operators. But as the piecewise continuous interval of each operator reduces, the model tends to be ill-conditioned, especially at the turning points. Similar ill-conditioned situation arises when these actuators move heavy loads or operate at high frequency. This paper proposes an extended PI operator to map hysteresis to a domain where inversion is well behaved. The inverse weights are then evaluated to determine the inverse hysteresis model for the feedforward controller. For illustration purpose, a piezoelectric actuator is used.

16 July 2008 in IEEE Sensors Journal
Verified
Journal Article
Closed access
UTU-Xuan Tan
U-Xuan Tan
Kalyana Chakravarthy VeluvoluKalyana Chakravarthy Veluvolu
Kalyana Chakravarthy Veluvolu
WLWin Tun Latt
Win Tun Latt
CSCheng Yap Shee
Cheng Yap Shee
CRCameron N. Riviere
Cameron N. Riviere
WAWei Tech Ang
Wei Tech Ang
Inertial sensors, like accelerometers and gyroscopes, are rarely used by themselves to measure displacement. Accuracy of inertial sensors is greatly handicapped by the notorious integration drift, which arises due to numerical integration of the sensors zero bias error. A solution is proposed in this paper to provide drift free estimation of displacement from inertial sensors.

1 August 2007
Verified
Conference Paper
Closed access
Kalyana Chakravarthy VeluvoluKalyana Chakravarthy Veluvolu
Kalyana Chakravarthy Veluvolu
UTU. X. Tan
U. X. Tan
WLW. T. Latt
W. T. Latt
CSC. Y. Shee
C. Y. Shee
WAWei Tech Ang
Wei Tech Ang
Surgical accuracy of the hand-held instruments depends on the active compensation of disturbance and tremor. Physiological tremor is one of the main causes for imprecision in micro-surgery procedures. One of the popular tremor compensation methods is based on weighted-frequency Fourier linear combiner (WFLC) algorithm, that can adapt to the changes in frequency as well as amplitude of the tremor signal. WLFC estimates the dominant frequency and the amplitude. For the case of tremor with frequency variation or comprising of two or three frequencies close in spectral domain, the WFLC performance is degraded. In this paper, we present a bandlimited multiple Fourier linear combiner that can track the modulated signals with multiple frequency components. We also discuss the tremor sensing with accelerometers. Using the proposed algorithm the drift caused by the accelerometers is also eliminated. The proposed filter is tested in real-time for 1-DOF cancellation of tremor.

8 September 2020 in Scientific Data
Verified
Journal Article
Open access
PDF file
PLPhyllis Liang
Phyllis Liang
Patrick KwongPatrick Kwong
Patrick Kwong
Ananda SIDARTAAnanda SIDARTA
Ananda SIDARTA
CYChoon Kong Yap
Choon Kong Yap
WTWee Kiat Tan
Wee Kiat Tan
WAWei Tech Ang
Wei Tech Ang
Assessment of human movement performance in activities of daily living (ADL) is a key component in clinical and rehabilitation settings. Motion capture technology is an effective method for objective assessment of human movement. Existing databases capture human movement and ADL performance primarily in the Western population, and there are no Asian databases to date. This is despite the fact that Asian anthropometrics influence movement kinematics and kinetics. This paper details the protocol in the first phase of the largest Asian normative human movement database. Data collection has commenced, and this paper reports 10 healthy participants. Twelve tasks were performed and data was collected using Qualisys motion capture system, force plates and instrumented table and chair. In phase two, human movement of individuals with stroke and knee osteoarthritis will be captured. This can have great potential for benchmarking with the normative human movement captured in phase one and predicting recovery and progression of movement for patients. With individualised progression, it will offer the development of personalised therapy protocols in rehabilitation.

31 May 2011 in Sensors
Verified
Journal Article
Open access
PDF file
WLWin Tun Latt
Win Tun Latt
Kalyana Chakravarthy VeluvoluKalyana Chakravarthy Veluvolu
Kalyana Chakravarthy Veluvolu
WAWei Tech Ang
Wei Tech Ang
Position sensing with inertial sensors such as accelerometers and gyroscopes usually requires other aided sensors or prior knowledge of motion characteristics to remove position drift resulting from integration of acceleration or velocity so as to obtain accurate position estimation. A method based on analytical integration has previously been developed to obtain accurate position estimate of periodic or quasi-periodic motion from inertial sensors using prior knowledge of the motion but without using aided sensors. In this paper, a new method is proposed which employs linear filtering stage coupled with adaptive filtering stage to remove drift and attenuation. The prior knowledge of the motion the proposed method requires is only approximate band of frequencies of the motion. Existing adaptive filtering methods based on Fourier series such as weighted-frequency Fourier linear combiner (WFLC), and band-limited multiple Fourier linear combiner (BMFLC) are modified to combine with the proposed method. To validate and compare the performance of the proposed method with the method based on analytical integration, simulation study is performed using periodic signals as well as real physiological tremor data, and real-time experiments are conducted using an ADXL-203 accelerometer. Results demonstrate that the performance of the proposed method outperforms the existing analytical integration method.