Van Hiep Pham

Dr. Van Hiep Pham

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Photoacoustics
Verified
Journal Article
Open access
VNVan Tu Nguyen
Van Tu Nguyen
NTNguyen Thanh Phong Truong
Nguyen Thanh Phong Truong
VPVan Hiep Pham
Van Hiep Pham
JCJaeyeop Choi
Jaeyeop Choi
SPSumin Park
Sumin Park
JOJunghwan Oh
Junghwan Oh
Photoacoustic microscopy (PAM) is an important imaging tool that can noninvasively visualize the anatomical structure of living animals. However, the limited scanning area restricts traditional PAM systems for scanning a large animal. Here, we firstly report a dual-channel PAM system based on a custom-made slider-crank scanner. This novel scanner allows us to stably capture an ultra-widefield scanning area of 24 mm at a high B-scan speed of 32 Hz while maintaining a high signal-to-noise ratio. Our system's spatial resolution is measured at ∼3.4 μm and ∼37 μm for lateral and axial resolution, respectively. Without any contrast agent, a dragonfly wing, a nude mouse ear, an entire rat ear, and a portion of mouse sagittal are successfully imaged. Furthermore, for hemodynamic monitoring, the mimicking circulating tumor cells using magnetic contrast agent is rapidly captured in vitro. The experimental results demonstrated that our device is a promising tool for biological applications.

27 April 2023 in Expert Systems with Applications
Verified
Journal Article
Closed access
VPVan Hiep Pham
Van Hiep Pham
TVTan Hung Vo
Tan Hung Vo
DVDinh Dat Vu
Dinh Dat Vu
JCJaeyeop Choi
Jaeyeop Choi
SPSumin Park
Sumin Park
VPVan Hiep Pham
Van Hiep Pham

4 May 2022 in Research in Nondestructive Evaluation
Verified
Journal Article
Closed access
VPVan Hiep Pham
Van Hiep Pham
TVTan Hung Vo
Tan Hung Vo
DVDinh Dat Vu
Dinh Dat Vu
JCJaeyeop Choi
Jaeyeop Choi
SPSumin Park
Sumin Park
JOJunghwan Oh
Junghwan Oh
Scanning acoustic microscopy (SAM) system (TSAM-400) was designed and developed for evaluating the quality of resistance spot welding (RSW) joints of 1.5 mm-thick SUS 316 stainless steel sheets under different welding parameters. Indentation and nugget information (diameter and shape) were used for evaluating the RSW quality. SAM A-scan signals were used to calculate the indentation. The nugget diameter was determined in the C-scan image. Internal information (nugget shape, splashes, and defects) was visualized in the B- and C-scan images. In addition, the spot weld area was treated to examine the surface topography effect. The nugget diameters of treated and untreated areas were measured and compared to conclude that the surface topography effect can be neglected in the quality evaluation by SAM system. By implementing TSAM-400, some specimens were successfully tested with a scanning area of 55 × 15 mm2, and a scanning time of 33.5 s corresponding to a B-scan frame rate of 4.5 Hz, and a resolution of 0.1 × 0.1 mm2. Finally, the good input parameters for welding two 1.5 mm-thick SUS 316 were determined by analyzing the results from TSAM-400.

10 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
VPVan Hiep Pham
Van Hiep Pham
THTran Le Hai
Tran Le Hai
JCJaeyeop Choi
Jaeyeop Choi
HTHoanh Son Truong
Hoanh Son Truong
TVTan Hung Vo
Tan Hung Vo
JOJunghwan Oh
Junghwan Oh
A scanning acoustic microscopy (SAM) system is a common non-destructive instrument which is used to evaluate the material quality in scientific and industrial applications. Technically, the tested sample is immersed in water during the scanning process. Therefore, a robot arm is incorporated into the SAM system to transfer the sample for in-line inspection, which makes the system complex and increases time consumption. The main aim of this study is to develop a novel water probe for the SAM system, that is, a waterstream. During the scanning process, water was supplied using a waterstream instead of immersing the sample in the water, which leads to a simple design of an automotive SAM system and a reduction in time consumption. In addition, using a waterstream in the SAM system can avoid contamination of the sample due to immersion in water for long-time scanning. Waterstream was designed based on the measured focal length calculation of the transducer and simulated to investigate the internal flow characteristics. To validate the simulation results, the waterstream was prototyped and applied to the TSAM-400 and W-FSAM traditional and fast SAM systems to successfully image some samples such as carbon fiber-reinforced polymers, a printed circuit board, and a 6-inch wafer. These results demonstrate the design method of the water probe applied to the SAM system.

22 May 2026 in Materials
Verified
Journal Article
Open access
PDF file
TPThi Nhat Linh Phan
Thi Nhat Linh Phan
TTThi Thuy Truong
Thi Thuy Truong
TVTan Hung Vo
Tan Hung Vo
VPVan Hiep Pham
Van Hiep Pham
TNThi Xuan Nguyen
Thi Xuan Nguyen
SMSudip Mondal
Sudip Mondal
Three-dimensional (3D) bioprinting has rapidly evolved into a controlling platform for the fabrication of patient-specific biomedical implants, with growing importance in advanced drug delivery systems. Beyond structural tissue engineering, bioprinted constructs now function as programmable therapeutic depots capable of localized, sustained, and stimuli-responsive drug release. This review focuses on recent biomaterial design strategies that enable precise control over drug encapsulation, retention, and release kinetics within 3D bioprinted architectures. The physicochemical and mechanical properties of bioinks, including crosslinking density, porosity, degradation behavior, viscoelasticity, and swelling characteristics, directly influence drug loading efficiency and release dynamics under physiological conditions. The rational tuning of these parameters allows the development of constructs that provide spatially controlled and temporally regulated therapeutic delivery. Recent advances in predictive modeling, such as finite element modeling (FEM), data-driven machine learning approaches, and ML, have significantly improved the ability to correlate material composition, printing parameters, and structural geometry with drug diffusion and degradation-mediated release mechanisms. These tools facilitate the optimization of printing variables including extrusion pressure, nozzle diameter, and layer resolution to ensure structural fidelity while maintaining therapeutic functionality. Emerging strategies incorporating multi-material printing, gradient architectures, and stimuli-responsive biomaterials have expanded the potential of 3D bioprinting for combination therapies and personalized medicine. This review discusses key challenges in translating bioprinted drug delivery systems into clinical applications, including the standardization of drug release characterization methods, and long-term stability assessment.

4 June 2025 in Scientific Reports
Verified
Journal Article
Open access
VPVan Hiep Pham
Van Hiep Pham
TVTuan Nguyen Van
Tuan Nguyen Van
PNPhong Cong Hong Nguyen
Phong Cong Hong Nguyen
TDTu Anh Do
Tu Anh Do
HTHoanh-Son Truong
Hoanh-Son Truong
XLXuan Luc Le
Xuan Luc Le
This study presents a simple method for balancing a slider-crank mechanism which is applied to a new system. A counterweight is designed and located on the crank link to solve the vibration of slider-crank mechanism. The calculation of counterweight design is proposed to balance the single and double slider-crank mechanisms which are exploited to develop the fast scanning module of scanning acoustic microscopy (SAM) system. Based on the ultrasound characteristics, SAM system can provide the internal image with high resolution up to several tens of micrometers. Following that, the counterweight is optimized to minimize the shaking force acting on the ground frame, resulting in vibration reduction of the SAM system. The equations of shaking force are defined, which are simulated to find out the shape and size of suitable counterweight. Based on the simulation results, counterweights were designed and fabricated, which were used for single and double slider-crank mechanisms of two SAM systems. By interpreting the scanning images provided by SAM systems, the dimensions of specimen are measured at minimum and maximum values that are used to validate the counterweight calculation. Finally, the design process flowchart of counterweight is proposed for balancing slider-crank mechanism, which can be used to extend the mechanism application in many fields.