Sarah Tonello

Dr. Sarah Tonello

Department of Information Engineering, University of Padua, 35131 Padua, Italy
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
Emilio SardiniEmilio Sardini
Emilio Sardini
Mauro SerpelloniMauro Serpelloni
Mauro Serpelloni
Sarah TonelloSarah Tonello
Sarah Tonello
Printed electrochemical biosensors have recently gained increasing relevance in fields ranging from basic research to home-based point-of-care. Thus, they represent a unique opportunity to enable low-cost, fast, non-invasive and/or continuous monitoring of cells and biomolecules, exploiting their electrical properties. Printing technologies represent powerful tools to combine simpler and more customizable fabrication of biosensors with high resolution, miniaturization and integration with more complex microfluidic and electronics systems. The metrological aspects of those biosensors, such as sensitivity, repeatability and stability, represent very challenging aspects that are required for the assessment of the sensor itself. This review provides an overview of the opportunities of printed electrochemical biosensors in terms of transducing principles, metrological characteristics and the enlargement of the application field. A critical discussion on metrological challenges is then provided, deepening our understanding of the most promising trends in order to overcome them: printed nanostructures to improve the limit of detection, sensitivity and repeatability; printing strategies to improve organic biosensor integration in biological environments; emerging printing methods for non-conventional substrates; microfluidic dispensing to improve repeatability. Finally, an up-to-date analysis of the most recent examples of printed electrochemical biosensors for the main classes of target analytes (live cells, nucleic acids, proteins, metabolites and electrolytes) is reported.

7 March 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MKMuhammad Ahmed Khan
Muhammad Ahmed Khan
ECEdoardo Cantù
Edoardo Cantù
Sarah TonelloSarah Tonello
Sarah Tonello
Mauro SerpelloniMauro Serpelloni
Mauro Serpelloni
Nicola Francesco LopomoNicola Francesco Lopomo
Nicola Francesco Lopomo
Emilio SardiniEmilio Sardini
Emilio Sardini
During the last years, scientific research in biotechnology has been reporting a considerable boost forward due to many advances marked in different technological areas. Researchers working in the field of regenerative medicine, mechanobiology and pharmacology have been constantly looking for non-invasive methods able to track tissue development, monitor biological processes and check effectiveness in treatments. The possibility to control cell cultures and quantify their products represents indeed one of the most promising and exciting hurdles. In this perspective, the use of conductive materials able to map cell activity in a three-dimensional environment represents the most interesting approach. The greatest potential of this strategy relies on the possibility to correlate measurable changes in electrical parameters with specific cell cycle events, without affecting their maturation process and considering a physiological-like setting. Up to now, several conductive materials has been identified and validated as possible solutions in scaffold development, but still few works have stressed the possibility to use conductive scaffolds for non-invasive electrical cell monitoring. In this picture, the main objective of this review was to define the state-of-the-art concerning conductive biomaterials to provide researchers with practical guidelines for developing specific applications addressing cell growth and differentiation monitoring. Therefore, a comprehensive review of all the available conductive biomaterials (polymers, carbon-based, and metals) was given in terms of their main electric characteristics and range of applications.

1 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ECEdoardo Cantù
Edoardo Cantù
Sarah TonelloSarah Tonello
Sarah Tonello
GAGIULIA ABATE
GIULIA ABATE
Daniela UbertiDaniela Uberti
Daniela Uberti
Emilio SardiniEmilio Sardini
Emilio Sardini
Mauro SerpelloniMauro Serpelloni
Mauro Serpelloni
The use of electrochemical sensors for the analysis of biological samples is nowadays widespread and highly demanded from diagnostic and pharmaceutical research, but the reliability and repeatability still remain debated issues. In the expanding field of printed electronics, Aerosol Jet Printing (AJP) appears promising to bring an improvement in resolution, miniaturization, and flexibility. In this paper, the use of AJP is proposed to design and fabricate customized electrochemical sensors in term of geometry, materials and 3D liquid sample confinement, reducing variability in the functionalization process. After an analysis of geometrical, electrical and surface features, the optimal layout has been selected. An electrochemical test has been then performed quantifying Interleukin-8, selected as reference protein, by means of Anodic Stripping Voltammetry. AJP sensors have been compared with standard screen-printed electrodes in terms of current density and relative standard deviation. Results from AJP sensors with Ag-based Anodic Stripping Voltammetry confirmed nanostructures capability to reduce the limit of detection (from 2.1 to 0.3 ng/mL). Furthermore, AJP appeared to bring an improvement in term of relative standard deviation from 50 to 10%, if compared to screen-printed sensors. This is promising to improve reliability and repeatability of measurement techniques integrable in several biotechnological applications.

18 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NNNicolò Di Novo
Nicolò Di Novo
ECEdoardo Cantù
Edoardo Cantù
Sarah TonelloSarah Tonello
Sarah Tonello
Emilio SardiniEmilio Sardini
Emilio Sardini
Mauro SerpelloniMauro Serpelloni
Mauro Serpelloni
Printed electronics have led to new possibilities in the detection and quantification of a wide range of molecules important for medical, biotechnological, and environmental fields. The integration with microfluidics is often adopted to avoid hand-deposition of little volumes of reagents and samples on miniaturized electrodes that strongly depend on operator’s skills. Here we report design, fabrication and test of an easy-to-use electrochemical sensor platform with microfluidics entirely realized with Aerosol Jet Printing (AJP). We printed a six-electrochemical-sensors platform with AJP and we explored the possibility to aerosol jet print directly on it a microfluidic structure without any support material. Thus, the sacrificial material removal and/or the assembly with sensors steps are avoided. The repeatability observed when printing both conductive and ultraviolet (UV)-curable polymer inks can be supported from the values of relative standard deviation of maximum 5% for thickness and 9% for line width. We designed the whole microfluidic platform to make the sample deposition (20 μL) independent from the operator. To validate the platform, we quantified glucose at different concentrations using a standard enzyme-mediated procedure. Both mediator and enzyme were directly aerosol jet printed on working electrodes (WEs), thus the proposed platform is entirely fabricated by AJP and ready to use. The chronoamperometric tests show limit of detection (LOD) = 2.4 mM and sensitivity = 2.2 ± 0.08 µA/mM confirming the effectiveness of mediator and enzyme directly aerosol jet printed to provide sensing in a clinically relevant range (3–10 mM). The average relative standard inter-platform deviation is about 8%. AJP technique can be used for fabricating a ready-to-use microfluidic device that does not need further processing after fabrication, but is promptly available for electrochemical sample analysis.

1 May 2019 in Biochimica et Biophysica Acta (BBA) - General Subjects
Verified
Journal Article
Closed access
MMMariagrazia Marziano
Mariagrazia Marziano
Sarah TonelloSarah Tonello
Sarah Tonello
ECE. Cantù
E. Cantù
GAGIULIA ABATE
GIULIA ABATE
MVM. Vezzoli
M. Vezzoli
DUD. Uberti
D. Uberti

23 January 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
GPGiorgia Polidori
Giorgia Polidori
Sarah TonelloSarah Tonello
Sarah Tonello
Mauro SerpelloniMauro Serpelloni
Mauro Serpelloni
The recent advancements in technologies related to printed electronics brought significant innovation in the design and fabrication of electrochemical miniaturized sensors. One of the most exciting categories that can benefit from the transition from macro to micro enabled by novel printing techniques is ion-selective electrodes (ISEs). Miniaturized ISEs are also called All-Solid State ISEs (ASS-ISEs) since they rely on a solid contact transduction layer, enabling easier miniaturization and integration. This is particularly interesting for a wide variety of applications ranging from medical to industrial. In all these fields, printed ASS-ISEs have been proven to reach significant results in terms of metrological properties obtaining near-Nernstian sensitivities, limits of detection down to 10-10, best selectivity coefficients around 10-8, shorter response time lower than 5 s, stability reaching 6 months and optimal variabilities (with best repeatability lower than 1% and reproducibility lower than 2%). The use of innovative printing techniques could further enhance these properties, as well as improve aspects such as flexibility, material waste, resolution improvement, and the finest control of surface functionalization. Even though a wide range of examples has multiplied in the literature over the past decade, to date, most of them still lack uniformity or detailed guidance regarding both the fabrication process and the metrological characterization procedure. With this in mind, this review aims to serve as a guideline for the identification of project specifications for the design, fabrication, and test of ion-selective all-solid-state printed sensors, as well as to propose a common metric in characterizing these devices.