Giorgia Polidori

Ms. Giorgia Polidori

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
GPGiorgia Polidori
Giorgia Polidori
Sarah TonelloSarah Tonello
Sarah Tonello
Mauro SerpelloniMauro Serpelloni
Mauro Serpelloni
The recent advancements in technologies related to printed electronics brought significant innovation in the design and fabrication of electrochemical miniaturized sensors. One of the most exciting categories that can benefit from the transition from macro to micro enabled by novel printing techniques is ion-selective electrodes (ISEs). Miniaturized ISEs are also called All-Solid State ISEs (ASS-ISEs) since they rely on a solid contact transduction layer, enabling easier miniaturization and integration. This is particularly interesting for a wide variety of applications ranging from medical to industrial. In all these fields, printed ASS-ISEs have been proven to reach significant results in terms of metrological properties obtaining near-Nernstian sensitivities, limits of detection down to 10-10, best selectivity coefficients around 10-8, shorter response time lower than 5 s, stability reaching 6 months and optimal variabilities (with best repeatability lower than 1% and reproducibility lower than 2%). The use of innovative printing techniques could further enhance these properties, as well as improve aspects such as flexibility, material waste, resolution improvement, and the finest control of surface functionalization. Even though a wide range of examples has multiplied in the literature over the past decade, to date, most of them still lack uniformity or detailed guidance regarding both the fabrication process and the metrological characterization procedure. With this in mind, this review aims to serve as a guideline for the identification of project specifications for the design, fabrication, and test of ion-selective all-solid-state printed sensors, as well as to propose a common metric in characterizing these devices.

12 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
GPGiorgia Polidori
Giorgia Polidori
Emilio SardiniEmilio Sardini
Emilio Sardini
Mauro SerpelloniMauro Serpelloni
Mauro Serpelloni
This work evaluates a potassium ion-selective electrode (K-ISE) fabricated using Aerosol Jet Printing (AJP) and compares its performance with that of a commercial K+-selective electrode (KION). Both sensors exhibit near-Nernstian behavior, with average sensitivities of 57.91 ± 5.07 mV/dec for the AJP device and 57.28 ± 5.07 mV/dec for the commercial electrode, confirming a near-Nernstian K+ response over the tested concentration range. Single-interferent response tests demonstrate that AJP-printed electrodes provide a more stable and less sensitive response to sodium interference (24.37 ± 1.39 mV/dec) compared to KION (33.95 ± 8.95 mV/dec), while showing comparable NH4+ response and a slightly higher response toward urea than KION. Morphological analysis (OM and SEM) reveals that AJP enables smoother, more homogeneous films and improved control over the transducer/membrane interface. Unlike previous studies, this work presents a direct experimental comparison between AJP-fabricated and commercial ISEs under controlled interference conditions relevant to agricultural and environmental matrices. Although the AJP sensors exhibited near-Nernstian behavior and fast response times, their reproducibility was lower than that of the commercial electrodes (RSD = 30.12% vs. 18.45%), indicating that further optimization of the printing and membrane deposition processes is required.

26 June 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
VBValerio Brunacci
Valerio Brunacci
Domenico CapriglioneDomenico Capriglione
Domenico Capriglione
CCChiara Carissimo
Chiara Carissimo
DCDamiano Crescini
Damiano Crescini
FMFilippo Milano
Filippo Milano
MSMauro Serpelloni
Mauro Serpelloni
Soil contamination monitoring and precision nutrient assessment require measurement systems capable of operating directly in subsurface environments while ensuring reliable spatial referencing of collected data. This paper presents a novel integrated autonomous solution for underground monitoring and mapping, combining in-line pollutant sensing with magnetic-field-based localization in a unified architecture designed for deployment on drilling or burrowing robotic platforms. The proposed system integrates: (i) a nearinfrared (NIR) spectroscopy module coupled with a convolutional neural network (CNN) for the estimation of urea-nitrogen content; (ii) a solid-state ion-selective electrochemical sensing unit for selective potassium detection in soil-derived aqueous extracts; and (iii) an AC magnetic localization subsystem based on surface transmitting anchors and a triaxial underground receiver. The architecture is designed to ensure tight coupling between measurement and positioning, enabling spatially consistent subsurface pollutant mapping in GNSS-denied environments. The NIR–CNN approach demonstrated reliable urea-N estimation (R² = 0.78, RMSE = 2.51%), while the electrochemical subsystem provided selective and repeatable potassium measurements with improved sensitivity in additively manufactured sensors. The magnetic localization algorithm achieved sub-decimeter accuracy in simulation (RMSE ≈ 8.8 cm) and decimeter-level performance in outdoor experimental validation, confirming the feasibility of real-time underground positioning within operational constraints of drilling platforms. The results demonstrate the effectiveness of the proposed integrated sensing and localization framework for subsurface environmental monitoring, supporting future applications in precision agriculture, soil contamination assessment, and autonomous underground exploration.

22 May 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
GPGiorgia Polidori
Giorgia Polidori
AVANDREA VISANI
ANDREA VISANI
Gianluca GiavaresiGianluca Giavaresi
Gianluca Giavaresi
Mauro SerpelloniMauro Serpelloni
Mauro Serpelloni
Gregorio MarchioriGregorio Marchiori
Gregorio Marchiori
Sensors are an established driver of diagnostics and prevention in the medical field, including orthopaedics. Today, the subclass of ion-selective sensors (ISSs) is on the leading edge due to its advantages, enabled by technological advancements in manufacturing, such as miniaturization, precision, accuracy, specificity, a wide measuring scale, ease of use, flexible operating conditions, and measuring speed. While ISSs’ impact on environmental and health fields is already the subject of investigation, it still needs to be analysed specifically in orthopaedics, which is the aim of this Review. A PubMed and Scopus search was performed using the keywords “ion”, “sensor”, “electrodes”, “selective”, “musculoskeletal”, “implant”, “joint replacement”, and “orthopaedic”; after systematic screening, 44 studies were included in the synthesis. First, studies were classified based on the target ion. Only a few papers treated applications specifically in orthopaedics, confirming that ISSs are still largely an unexplored frontier here. However, all of the studies targeted ions with a role also in musculoskeletal pathophysiology, thus relative ISSs could have a potential impact on orthopaedic diagnosis and treatment. Then, when described by the papers, ISSs’ technological solutions were systematically evaluated. Finally, the main ISSs development targets for reaching orthopaedic clinical application were highlighted, including biocompatibility (e.g., implantability), long-term stability, calibration, and validation. Overcoming these challenges will enable ISSs to progress from laboratory prototypes to clinically viable tools, supporting the advancement of next-generation sensorised prostheses, fixation devices, and surgical instruments, and paving the way for predictive and personalised orthopaedic medicine.