12 April 2024 in Electronics
Verified
Journal Article
Open access
PDF file
JWJulia Grasiela Busarello Wolff
Julia Grasiela Busarello Wolff
Rafael KingeskiRafael Kingeski
Rafael Kingeski
Wellington Pinheiro dos SantosWellington Pinheiro dos Santos
Wellington Pinheiro dos Santos
JCJosé Cristani
José Cristani
STSandra Davi Traverso
Sandra Davi Traverso
APA. S. Paterno
A. S. Paterno
This article introduces a new MfEIT UDESC Mark I system, which consists of a 32-electrode setup featuring a modified Howland current source, low cost, portability, and non-radiation. The system is capable of reconstructing electrical conductivity tomographic images at a rate of 30.624 frames per second, taking about 5 min for imaging. The current source employs a 0.5 mA adjacent current application pattern with frequencies ranging from 10 kHz to 1 MHz. This article outlines the hardware, firmware, and software design specifications, which include the design of the current source, calibration procedures, and image reconstruction process. Tomographic images of conductivity were reconstructed in ex vivo healthy pig lungs and those with pneumonia, as a proof of concept for future applications in live pigs. The high spectral power density, combined with real-time system calibration provides clinical advantages in veterinary medicine. The goal is to identify lung areas affected by Mycoplasma hyopneumoniae in pigs through the analysis of electrical conductivity difference, offering a valuable tool to assist veterinarians to obtain images of respiratory diseases. The modified reconstruction method GREIT (EIDORS) was evaluated with experimental data and was compared with the Gauss–Newton and Total Variation methods, where GREIT 2D proved to be superior.

13 March 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
JWJulia Grasiela Busarello Wolff
Julia Grasiela Busarello Wolff
Rafael KingeskiRafael Kingeski
Rafael Kingeski
Wellington Pinheiro dos SantosWellington Pinheiro dos Santos
Wellington Pinheiro dos Santos
JCJosé Cristani
José Cristani
STSandra Davi Traverso
Sandra Davi Traverso
APA. S. Paterno
A. S. Paterno
This article introduces a new MfEIT UDESC Mark I system, which consists of a 32-electrode setup featuring a modified Howland current source, low cost, portable and non radiation. The system is capable of reconstruction of electrical conductivity tomographic images at a rate of 30.624 frames per second and about 5 minutes for imaging. The current source employs 0.5 mA, adjacent current application pattern with frequencies ranging from 10 kHz to 1 MHz. The article outlines the hardware, firmware, and software design specifications, which include the design of the current source, calibration procedures, and image reconstruction process. Tomographic images of conductivity were reconstructed in ex vivo healthy pig lungs and those with pneumonia, as a proof of concept for future applications in live pigs. The high spectral power density, combined with real-time system calibration provides clinical advantages in veterinary medicine. The goal is to identify lung areas affected by Mycoplasma hyopneumoniae in pigs, through the analysis of electrical conductivity difference, offering a valuable tool to assist veterinarians for to obtain images of respiratory diseases. The reconstruction method (GREIT) was evaluated with experimental data and It was compared with the Gauss-Newton and Total Variation methods, where GREIT proved to be superior.

11 March 2025 in Research Square
Verified
Preprint
Open access
PDF file
JWJulia Grasiela Busarello Wolff
Julia Grasiela Busarello Wolff
Rafael KingeskiRafael Kingeski
Rafael Kingeski
FNFabrício Noveletto
Fabrício Noveletto
Wellington Pinheiro dos SantosWellington Pinheiro dos Santos
Wellington Pinheiro dos Santos
APA. S. Paterno
A. S. Paterno
MHMarcelo da Silva Hounsell
Marcelo da Silva Hounsell
Multifrequency Electrical Impedance Tomography (MfEIT) is a safe, non-invasive, radiation-free technique that visualizes conductivity distribution within an object. Vegetables and animal tissues are often used to calibrate and validate MfEIT systems. This paper presents the calibration of image reconstruction algorithms using eight cucumber samples. An academic MfEIT model obtained edge voltage data at frequencies of 10k, 50k, 100k, and 200 kHz and gains of 5, 10, 60, 150, 200, and 250. Four algorithms were selected for image reconstruction: Graz Consensus for Electrical Impedance Tomography (GREIT); One-Step Gauss-Newton (OSGN); Total Variation Primal-Dual Interior Point Method (TV-PDIPM); and Gauss-Newton Absolute Reconstruction Method (GN-ARM). This work explores key factors influencing image quality, including gain, frequency, hyperparameter values, and reconstruction algorithms. Hyperparameters in algorithms play an important role in fine-tuning image reconstruction models, directly influencing the accuracy, stability, and computational efficiency of the obtained solutions. For this reason, they were systematically varied and tested in this work, aiming to identify the optimal configurations that ensure the best performance of the algorithms in different reconstruction scenarios. The cucumber sample at 250 gain and 100 kHz with GN-ARM produced the best image.