The surging prevalence of diabetes globally necessitates advancements in non-invasive diagnostics, particularly for the early detection of cardiovascular anomalies associated with the condition. This study explores the efficacy of Pulse Wave Analysis (PWA) for distinguishing diabetic from non-diabetic individuals through morphological examination of pressure pulse waveforms. The research unfolds in four phases: data accrual, preprocessing, Convolutional Neural Network (CNN) model construction, and performance evaluation. Data were procured using a multipara patient monitor, resulting in 2000 pulse waves equally divided between healthy individuals and those with diabetes. These were used to train, validate, and test three distinct CNN architectures: the conventional CNN, Visual Geometry Group (VGG16), and Residual Networks (ResNet18). The accuracy, precision, recall, and F1 score gauged each model’s proficiency. The CNN demonstrated a training accuracy of 82.09% and a testing accuracy of 80.6%. The VGG16, with its deeper structure, surpassed the baseline with training and testing accuracies of 90.2% and 86.57%, respectively. ResNet18 excelled, achieving a training accuracy of 92.50% and a testing accuracy of 92.00%, indicating its robustness in pattern recognition within pulse wave data. Deploying deep learning for diabetes screening marks progress, suggesting clinical use and future studies on bigger datasets for refinement.
Diabetes is a chronic disorder affecting vascular health, often altering pulse wave characteristics. Traditional pulse wave analysis (PWA) methods face challenges such as variability and complexity of signals. This study aims to overcome these limitations by leveraging deep learning models for more accurate and efficient classification. The methodology used in this study involves four key steps: data collection, data preprocessing, Convolutional Neural Network (CNN) model development, and model evaluation. Primary data were collected using a multipara patient monitor, including finger photoplethysmography (PPG) signals, blood pressure, mean arterial pressure, oxygen saturation, and pulse rate. Single pulse wave cycles from 60 healthy individuals and 60 patients with type 2 diabetes underwent preprocessing. The CNN model was trained using 50 PPG images from each group and achieved a training accuracy of 92%. The prediction capability of the model was evaluated using 20 unseen images, comprising 10 healthy and 10 diabetes PPG images. It attained a 90% overall test accuracy in distinguishing between PPG images of individuals with diabetes and those who are healthy. These findings suggest that CNN-based analysis of PPG signals provides a precise, non-invasive tool for diabetes screening. To further enhance accuracy, future studies should focus on increasing the dataset size and performing hyperparameter tuning to optimize the CNN model.
3 December 2025 in Biomedical Physics & Engineering Express
Hyperlipidemia detection involves invasive, time-consuming procedures requiring clinical laboratories and blood samples. Often asymptomatic in its early stages, hyperlipidemia significantly increases the risk of cardiovascular diseases. The objective of this study was to investigate whether hyperlipidemia produces detectable changes in pulse wave patterns and to develop a non-invasive, cost-effective diagnostic approach using deep learning techniques applied to finger pulse images. Pulse waves were recorded from 81 hyperlipidemia patients and 65 participants in the control group, with 700 single pulse wave cycles selected from each group. These waveforms were preprocessed and divided into training (70%), validation (15%), and testing (15%) subsets. Custom Convolutional Neural Network (CNN) architectures trained from scratch were developed and evaluated to identify the most effective classification model. After model selection, hyperparameter tuning was applied to enhance predictive performance. In parallel, pre-trained models such as Visual Geometry Group 16 (VGG16) were fine-tuned and optimized. The models were assessed using accuracy, precision, recall, and F1-score. The custom CNN models achieved the highest performance, with the top model reaching approximately 95%–96% for accuracy, precision, recall, and F1-score. The VGG16 models also performed well, with all metrics around 91%. Training and validation curves for both model types indicated strong learning capabilities with minimal overfitting or underfitting, showcasing their potential for generalization to unseen data. Deep learning models effectively differentiated pulse waves between individuals with hyperlipidemia and those in the control group, indicating that hyperlipidemia causes detectable changes in pulse wave patterns. This study could lead to the development of a reliable, efficient, and non-invasive device for hyperlipidemia screening.