Different biomedical computing methods for cancer specific gene recognition have been developed in recent years. Currently, how to build an open-box machine learning system to discover explainable knowledge from gene expression data is a difficult research problem due to a large number of genes, a small number of samples and noise. Fuzzy systems can be used to deal with data ambiguity and noise issues and extract meaningful knowledge from gene data. In this research, we create a new deep fuzzy neural network to handle uncertainty in gene data to generate useful knowledge for specific disease diagnosis. A new hybrid algorithm is designed to preprocess data and select informative genes for accurate cancer detection. Various experiments using six different cancer data sets indicate that the new method has better and more reliable performance than other conventional classification methods with different gene selection methods.
The surging prevalence of diabetes globally necessitates advancements in non-invasive diagnostics, particularly for the early detection of cardiovascular anomalies associated with the condition. This study explores the efficacy of Pulse Wave Analysis (PWA) for distinguishing diabetic from non-diabetic individuals through morphological examination of pressure pulse waveforms. The research unfolds in four phases: data accrual, preprocessing, Convolutional Neural Network (CNN) model construction, and performance evaluation. Data were procured using a multipara patient monitor, resulting in 2000 pulse waves equally divided between healthy individuals and those with diabetes. These were used to train, validate, and test three distinct CNN architectures: the conventional CNN, Visual Geometry Group (VGG16), and Residual Networks (ResNet18). The accuracy, precision, recall, and F1 score gauged each model’s proficiency. The CNN demonstrated a training accuracy of 82.09% and a testing accuracy of 80.6%. The VGG16, with its deeper structure, surpassed the baseline with training and testing accuracies of 90.2% and 86.57%, respectively. ResNet18 excelled, achieving a training accuracy of 92.50% and a testing accuracy of 92.00%, indicating its robustness in pattern recognition within pulse wave data. Deploying deep learning for diabetes screening marks progress, suggesting clinical use and future studies on bigger datasets for refinement.
On a narrow road, an accident is hard to avoid even for a responsible driver. If vehicles are stuck in traffic, driving on a single lane is worrying and takes time. For small vehicles, narrow roads pose unique challenges, especially in identifying large vehicles, hence reducing the likelihood of an accident. The study discovers these issues and presents how an inventive Intelligent Transportation System (ITS) has been developed as a worldwide phenomenon that aims at enhancing safety on narrow roads by integrating with mobile sensors. Smartphones are used by almost everyone today because their prices have gone down. The study examines the effectiveness of different machine learning models for the task of classifying vehicle type using (accelerometer, and gyroscope) sensors. The results reveal that the Random Forest model is the most effective having a mean accuracy rate of 99.78 %. Moreover, the trained Random Forest Model has been combined with an originally developed unique warning algorithm that integrates geofencing methods for drawing polygons around narrow roads and location data from smartphones. To summarise, this study adds to the development of safety systems in transport and offers useful ideas for developing and implementing real-time safety applications for narrow roads.
3 December 2025 in Biomedical Physics & Engineering Express
Hyperlipidemia detection involves invasive, time-consuming procedures requiring clinical laboratories and blood samples. Often asymptomatic in its early stages, hyperlipidemia significantly increases the risk of cardiovascular diseases. The objective of this study was to investigate whether hyperlipidemia produces detectable changes in pulse wave patterns and to develop a non-invasive, cost-effective diagnostic approach using deep learning techniques applied to finger pulse images. Pulse waves were recorded from 81 hyperlipidemia patients and 65 participants in the control group, with 700 single pulse wave cycles selected from each group. These waveforms were preprocessed and divided into training (70%), validation (15%), and testing (15%) subsets. Custom Convolutional Neural Network (CNN) architectures trained from scratch were developed and evaluated to identify the most effective classification model. After model selection, hyperparameter tuning was applied to enhance predictive performance. In parallel, pre-trained models such as Visual Geometry Group 16 (VGG16) were fine-tuned and optimized. The models were assessed using accuracy, precision, recall, and F1-score. The custom CNN models achieved the highest performance, with the top model reaching approximately 95%–96% for accuracy, precision, recall, and F1-score. The VGG16 models also performed well, with all metrics around 91%. Training and validation curves for both model types indicated strong learning capabilities with minimal overfitting or underfitting, showcasing their potential for generalization to unseen data. Deep learning models effectively differentiated pulse waves between individuals with hyperlipidemia and those in the control group, indicating that hyperlipidemia causes detectable changes in pulse wave patterns. This study could lead to the development of a reliable, efficient, and non-invasive device for hyperlipidemia screening.