Objective: Systolic time intervals, such as the pre-ejection period (PEP), are important parameters for assessing cardiac contractility that can be measured non-invasively using seismocardiography (SCG). Recent studies have shown that specific points on accelerometer- and gyroscope-based SCG signals can be used for PEP estimation. However, the complex morphology and inter-subject variation of the SCG signal can make this assumption very challenging and increase the root mean squared error (RMSE) when these techniques are used to develop a global model. Methods: In this study, we compared gyroscope- and accelerometer-based SCG signals, individually and in combination, for estimating PEP to show the efficacy of these sensors in capturing valuable information regarding cardiovascular health. We extracted general time-domain features from all the axes of these sensors and developed global models using various regression techniques. Results: In single-axis comparison of gyroscope and accelerometer, angular velocity signal around head to foot axis from the gyroscope provided the lowest RMSE of 12.63 ± 0.49 ms across all subjects. The best estimate of PEP, with a RMSE of 11.46 ± 0.32 ms across all subjects, was achieved by combining features from the gyroscope and accelerometer. Our global model showed 30% lower RMSE when compared to algorithms used in recent literature. Conclusion: Gyroscopes can provide better PEP estimation compared to accelerometers located on the mid-sternum. Global PEP estimation models can be improved by combining general time domain features from both sensors. Significance: This work can be used to develop a low-cost wearable heart-monitoring device and to generate a universal estimation model for systolic time intervals using a single- or multiple-sensor fusion.
26 July 2019 in IEEE Journal of Biomedical and Health Informatics
The seismocardiogram (SCG) is a noninvasively-obtained cardiovascular bio-signal that has gained traction in recent years, however is limited by its susceptibility to noise and motion artifacts. Because of this, signal quality must be assured before data are used to inform clinical care. Common methods of signal quality assurance include signal classification or assignment of a numerical quality index. Such tasks are difficult with SCG because there is no accepted standard for signal morphology. In this paper, we propose a unified method of quality indexing and classification that uses multi-subject-based methods to overcome this challenge. Dynamic-time feature matching is introduced as a novel method of obtaining the distance between a signal and reference template, with this metric, the signal quality index (SQI) is defined as a function of the inverse distance between the SCG and a large set of template signals. We demonstrate that this method is able to stratify SCG signals on held-out subjects based on their level of motion-artifact corruption. This method is extended, using the SQI as a feature for classification by ensembled quadratic discriminant analysis. Classification is validated by demonstrating, for the first time, both detection and localization of SCG sensor misplacement, achieving an F1 score of 0.83 on held-out subjects. This paper may provide a necessary step toward automating the analysis of SCG signals, addressing many of the key limitations and concerns precluding the method from being widely used in clinical and physiological sensing applications.
In this paper, we present a pilot study evaluating novel methods for assessing joint health in patients with Juvenile Idiopathic Arthritis (JIA) using wearable acoustical emission measurements from the knees. Measurements were taken from four control subjects with unknown knee injuries, and from four subjects with JIA, before and after treatment. Time and frequency domain features were extracted from the acoustical emission signals and used to compute a knee audio score. The score was used to separate out the two groups of subjects based solely on the sounds produced by their joints. It was created using a soft classifier based on gradient boosting trees. The knee audio scores ranged from 0-1 with 0 being a healthy knee and 1 being an involved joint with arthritis. Leave-one-subject-out cross-validation was used to validate the algorithm. The average of the right and left knee audio scores was 0.085±0.099 and 0.89±0.012 for the control group and group with JIA, respectively (p <; 0.05). The average knee audio score for the subjects with JIA decreased from 0.89 ± 0.012 to 0.25 ± 0.20 following successful treatment (p <; 0.05). The knee audio score metric successfully distinguished between the control subjects and subjects with JIA. The scores calculated before and after treatment accurately reflected the observed clinical course of the subjects with JIA. After successful treatment, the subjects with JIA were classified as healthy by the algorithm. Knee acoustical emissions provide a novel and cost-effective method for monitoring JIA, and can be used as an objective guide for assessing treatment efficacy.
11 May 2021 in IEEE Journal of Biomedical and Health Informatics
Objective: Optimizing peri-operative fluid management has been shown to improve patient outcomes and the use of stroke volume (SV) measurement has become an accepted tool to guide fluid therapy. The Transesophageal Doppler (TED) is a validated, minimally invasive device that allows clinical assessment of SV. Unfortunately, the use of the TED is restricted to the intra-operative setting in anesthetized patients and requires constant supervision and periodic adjustment for accurate signal quality. However, post-operative fluid management is also vital for improved outcomes. Currently, there is no device regularly used in clinics that can track patient's SV continuously and non-invasively both during and after surgery. Methods: In this paper, we propose the use of a wearable patch mounted on the mid-sternum, which captures the seismocardiogram (SCG) and electrocardiogram (ECG) signals continuously to predict SV in patients undergoing major surgery. In a study of 12 patients, hemodynamic data was recorded simultaneously using the TED and wearable patch. Signal processing and regression techniques were used to derive SV from the signals (SCG and ECG) captured by the wearable patch and compare it to values obtained by the TED. Results: The results showed that the combination of SCG and ECG contains substantial information regarding SV, resulting in a correlation and median absolute error between the predicted and reference SV values of 0.81 and 7.56 mL, respectively. Significance: This work shows promise for the proposed wearable-based methodology to be used as an alternative to TED for continuous patient monitoring and guiding peri-operative fluid management.
29 July 2019 in IEEE Journal of Biomedical and Health Informatics
The ballistocardiography (BCG) signal is a measurement of the vibrations of the center of mass of the body due to the cardiac cycle and can be used for noninvasive hemodynamic monitoring. The seismocardiography (SCG) signals measure the local vibrations of the chest wall due to the cardiac cycle. While BCG is a more well known modality, it requires the use of a modified bathroom scale or a force plate and cannot be measured in a wearable setting, whereas SCG signals can be measured using wearable accelerometers placed on the sternum. In this work we explore the idea of finding a mapping between zero mean and unit $\ell_2$ -norm SCG and BCG signal segments such that, the BCG signal can be acquired using wearable accelerometers (without retaining amplitude information). We use neural networks to find such a mapping and make use of the recently introduced UNet architecture. We trained our models on 26 healthy subjects and tested them on 10 subjects. Our results show that we can estimate the aforementioned segments of the BCG signal with a median Pearson correlation coefficient of 0.71 and a median absolute deviation (MAD) of 0.17. Furthermore, our model can estimate the R-I, R-J and R-K timing intervals with median absolute errors (and MAD) of 10.00 (8.90), 6.00 (5.93) and 8.00 (5.93), respectively. We show that using all three axis of the SCG accelerometer produces the best results while the head-to-foot SCG signal produces the best results when a single SCG axis is used.
Individuals with obstructive sleep apnea (OSA) face increased accident risks due to excessive daytime sleepiness. PERCLOS, a recognized drowsiness detection method, encounters challenges from image quality, eyewear interference, and lighting variations, impacting its performance, and requiring validation through physiological signals. We propose visual-based scoring using adaptive thresholding for eye aspect ratio with OpenCV for face detection and Dlib for eye detection from video recordings. This technique identified 453 drowsiness (PERCLOS ≥ 0.3 || CLOSDUR ≥ 2 s) and 474 wakefulness episodes (PERCLOS < 0.3 and CLOSDUR < 2 s) among fifty OSA drivers in a 50 min driving simulation while wearing six-channel EEG electrodes. Applying discrete wavelet transform, we derived ten EEG features, correlated them with visual-based episodes using various criteria, and assessed the sensitivity of brain regions and individual EEG channels. Among these features, theta–alpha-ratio exhibited robust mapping (94.7%) with visual-based scoring, followed by delta–alpha-ratio (87.2%) and delta–theta-ratio (86.7%). Frontal area (86.4%) and channel F4 (75.4%) aligned most episodes with theta–alpha-ratio, while frontal, and occipital regions, particularly channels F4 and O2, displayed superior alignment across multiple features. Adding frontal or occipital channels could correlate all episodes with EEG patterns, reducing hardware needs. Our work could potentially enhance real-time drowsiness detection reliability and assess fitness to drive in OSA drivers.