Rafael Ecker

Mr. Rafael Ecker

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
AFAndreas Fuchsluger
Andreas Fuchsluger
APAnnalisa De Pastina
Annalisa De Pastina
RERafael Ecker
Rafael Ecker
TMTina Mitteramskogler
Tina Mitteramskogler
TVThomas Voglhuber-Brunnmaier
Thomas Voglhuber-Brunnmaier
BJBernhard Jakoby
Bernhard Jakoby
By using lateral extensional modes of piezoelectric plate transducers for the actuation of a microfluidic chip containing a structured microchannel, we achieved two-dimensional single-node acoustofluidic particle trapping inside a circular cavity as well as two-dimensional multi-node trapping in straight channels. In order to manipulate the particles in two lateral dimensions, we used two separate PZT transducers attached to the bottom of the microfluidic chip, where each is responsible for generating a standing acoustic wave in a specific direction inside the microfluidic structures of the chip. We demonstrate trapping of polymer microspheres and trapping of human embryonic kidney cells with a performance that can compete with current bulk acoustic methods which typically employ transducer thickness modes. The acoustic energy density of the involved acoustic fields reaches several hundred (430) Joules per cubic meter, leading to trapping times of tenths of a second (150 ms) and nanonewton trapping forces (0.42-1.7 nN). The relatively low, sub-megahertz resonance frequency of the utilized lateral transducer mode in the cavity trapping, results in a large, millimeter long wavelength of the acoustic wave inside the fluid, which enables collection of comparably large volumina of multiple tens of nanoliter containing several thousands of particles or cells. Consequently, with the large volumes involved, it appears feasible to trap bigger objects, like multicellular organisms or organoids with approximately one millimeter in size.

7 August 2023 in IEEE Access
Verified
Journal Article
Open access
RERafael Ecker
Rafael Ecker
TMTina Mitteramskogler
Tina Mitteramskogler
MLManuel Langwiesner
Manuel Langwiesner
AFAndreas Fuchsluger
Andreas Fuchsluger
MHMarcus A. Hintermüller
Marcus A. Hintermüller
BJBernhard Jakoby
Bernhard Jakoby
A modular microfluidic system can be used to quickly set up an individually adaptable microfluidic network by linking and delinking different functional building blocks. We present a convenient and reliable connection technology, which is based on magnets and casted O-ring-like structures leading to a sealed connection without the need of additional sealing materials. Based on an improved, previously presented fabrication technology, modular microfluidic polydimethylsiloxane (PDMS) blocks using a polyurethane (PU) mold, 3D printed acrylonitrile butadiene styrene (ABS) channel structures and a magnetic connection system in combination with a casted O-ring link, featuring various integration technologies have now been designed and experimentally evaluated. In particular, this paper will address the realization of directional valves, reciprocating pumps, finger pumps, directly-cast check- and Tesla-valves, fluidic flow sensors, fluidic mixers, commercial valves, and various sensors. By using different measurement setups, the feasibility of these devices is demonstrated. Moreover, limitations and issues encountered during fabrication as well as future work are discussed.

12 March 2024 in Proceedings
Verified
Conference Paper
Open access
PDF file
TMTina Mitteramskogler
Tina Mitteramskogler
AFAndreas Fuchsluger
Andreas Fuchsluger
RERafael Ecker
Rafael Ecker
TWThomas Wilfinger
Thomas Wilfinger
BJBernhard Jakoby
Bernhard Jakoby
RWRobert Wille
Robert Wille
Whether liquids in open microchannels show spontaneous capillary flow or not crucially depends on the involved surface energies and the shape of the microchannel. In this study, we present a two-dimensional model based on the Gibb’s free energy of a system that predicts the presence of spontaneous capillary flow in open microchannels. We expand our model to include curved microchannels and verify our findings using simulations of a liquid surface with Surface Evolver. Finally, we comment on how these results can be used to measure the liquid contact angle through open capillary flow.

18 March 2024 in Proceedings
Verified
Conference Paper
Open access
PDF file
AFAndreas Fuchsluger
Andreas Fuchsluger
APAnnalisa De Pastina
Annalisa De Pastina
TMTina Mitteramskogler
Tina Mitteramskogler
RERafael Ecker
Rafael Ecker
TVThomas Voglhuber-Brunnmaier
Thomas Voglhuber-Brunnmaier
BJBernhard Jakoby
Bernhard Jakoby
We present the concept and a proof-of-principle experiment for an acoustofluidic single- particle sorter. In a microfluidic channel, a flow profile with the following three parallel fluid domains is generated: buffer fluid in the center and buffer plus particles in the lateral domains. Due to the laminar flow regime present in microfluidics, the particles essentially follow the stream line(s) along the channel. In the spatially confined sorting and detection region, by switching on the standing acoustic wave, particles of interest (POIs) are pushed into the center fluid domain, thus leaving the chip at the center outlet. For particles of non-interest (PONIs), the acoustic region remains silent, so PONIs are not centered and follow their path to the side outlet.

19 March 2024 in Proceedings
Verified
Conference Paper
Open access
PDF file
RERafael Ecker
Rafael Ecker
TMTina Mitteramskogler
Tina Mitteramskogler
AFAndreas Fuchsluger
Andreas Fuchsluger
BJBernhard Jakoby
Bernhard Jakoby
This research work focuses on the fabrication of ultrathin polymethylmethacrylate (PMMA) foils using a spin coating process of in anisole dissolved PMMA on a water-soluble polyvinyl alcohol (PVA) foil. Currently, layer thicknesses as low as 1 µm can be achieved and even thinner layers appear to be possible. Sensors and actuators can be applied to the foils and directly integrated into the center of the channel of a polymer-based microfluidic chip. Specifically, the foil acts as a supporting structure that helps to position the sensor in the center of the channel. Thermal sensors, in particular, benefit from the low heat capacity of the foil. This will improve the performance and the accuracy of these sensors of which the impact on the fluidic flow is minimized.

9 August 2024 in IEEE Sensors Letters
Verified
Journal Article
Open access
RERafael Ecker
Rafael Ecker
TMTina Mitteramskogler
Tina Mitteramskogler
AFAndreas Fuchsluger
Andreas Fuchsluger
BJBernhard Jakoby
Bernhard Jakoby
A surface phenomenon known as the electric double layer effect occurs in a few atomic layers at the fluid–solid interface. By applying an external electric field, this phenomenon is used to generate a fluidic flow, which is called electroosmosis, and the corresponding device electroosmotic pumps (EOPs). In order to immensely increase the fluid–solid contact surface and, consequently, the fluid volume that generates the desired fluidic flow, an EOP employing a glass fiber filter in the main channel is presented in this letter. As a result, our EOP can reach high pressures of up to 400 kPa as well as high flow rates up to the milliliter per minute range. The devised technology enables low-cost EOP fabrication by using a polymethyl methacrylate substrate and mostly thermal-based fabrication processes. In order to address the challenges associated with spurious gas generation due to electrolysis, this EOP uses ion conductive membranes to keep the unwanted electrolysis process outside of the channel. To endure highly aggressive chemical reactions, platinum wires are furthermore employed as electrodes in the EOPs.