Mohamed A. Ghalib

Dr. Mohamed A. Ghalib


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MEM. S. Elborlsy
M. S. Elborlsy
RMR. M. Mostafa
R. M. Mostafa
MGMohamed A. Ghalib
Mohamed A. Ghalib
SBShimaa Barakat
Shimaa Barakat
HKH. E. Keshta
H. E. Keshta
Microgrids (MGs) are essential in the distribution system by utilizing widely dispersed generation sources. Due to their economical and environmentally friendly attributes, Islanded AC MGs are commonly used to supply electricity to isolated locations independent of the primary grid. This study focuses on optimizing the configuration of an islanded AC MG to meet the electrical requirements of an international school in the New Administrative Capital, New Cairo, Egypt. Hybrid Optimization of Multiple Energy Resources (HOMER) software is employed to obtain the optimal size of the sources in the MG by minimizing the Levelized Cost of Energy (LCOE) and Total Net Present Cost (TNPC). According to the HOMER simulation results, a 200 kW PV system, a 180-kW wind turbine, a 50 kW FC, a 50 kW electrolyzer, a 50 kg hydrogen tank, a 180 kW DG, and a 686-kWh lead-acid battery form the optimal configuration of the islanded AC MG. The results reveal the contribution of each energy component to meeting the electricity demand, yielding an LCOE of $0.153/kWh and a TNPC of $1,775,300.00. The dynamic performance of the islanded microgrid is examined, introducing a Model Reference Adaptive Control based PI controller (MRAC-PI) to enhance transient response across all operational conditions. A comparative analysis is performed against traditional PI-PSO and PI-WOA controllers under load variations and changing weather conditions. The results indicate that the proposed control strategy effectively maintains system frequency and voltage amid various disturbances, improves dynamic performance, and achieves a balanced power generation and load demand. Additionally, the proposed controller demonstrates superior dynamic response, featuring reduced overshoot, undershoot, ITAE, and settling time compared to the others.

28 March 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SHSamir A. Hamad
Samir A. Hamad
MGMohamed A. Ghalib
Mohamed A. Ghalib
AMAmr Munshi
Amr Munshi
MAMajid Alotaibi
Majid Alotaibi
MEMostafa A. Ebied
Mostafa A. Ebied
This paper presents a machine learning (ML) model designed to track the maximum power point of standalone Photovoltaic (PV) systems. Due to the nonlinear nature of power generation in PV systems, influenced by fluctuating weather conditions, managing this nonlinear data effectively remains a challenge. As a result, the use of ML techniques to optimize PV systems at their MPP is highly beneficial. To achieve this, the research explores various ML algorithms, such as Linear Regression (LR), Ridge Regression (RR), Lasso Regression (Lasso R), Bayesian Regression (BR), Decision Tree Regression (DTR), Gradient Boosting Regression (GBR), and Artificial Neural Networks (ANN), to predict the MPP of PV systems. The model utilizes data from the PV unit’s technical specifications, allowing the algorithms to forecast maximum power, current, and voltage based on given irradiance and temperature inputs. Predicted data is also used to determine the boost converter’s duty cycle. The simulation was conducted on a 100 kW solar panel with an open-circuit voltage of 64.2 V and a short-circuit current of 5.96 A. Model performance was evaluated using metrics such as Root Mean Square Error (RMSE), Coefficient of Determination (R2), and Mean Absolute Error (MAE). Additionally, the study assessed the correlation and feature importance to evaluate model compatibility and the factors impacting the predictive accuracy of the ML models. Results showed that the DTR algorithm outperformed others like LR, RR, Lasso R, BR, GBR, and ANN in predicting the maximum current (Im), voltage (Vm), and power (Pm) of the PV system. The DTR model achieved RMSE, MAE, and R2 values of 0.006, 0.004, and 0.99999 for Im, 0.015, 0.0036, and 0.99999 for Vm, and 2.36, 0.871, and 0.99999 for Pm. Factors such as the size of the training dataset, operating conditions of the PV system, model type, and data preprocessing were found to significantly influence prediction accuracy.

18 November 2025 in Scientific Reports
Verified
Journal Article
Open access
MGMohamed A. Ghalib
Mohamed A. Ghalib
MEM. S. Elbrolsy
M. S. Elbrolsy
RMR. M. Mostafa
R. M. Mostafa
HKH.E. Keshta
H.E. Keshta
The concept of Islanded Hybrid Power System (IHPS) has attracted considerable interest lately, especially for energizing remote or energy-poor locations. IHPS are more dependable and cost-effective alternatives to systems using only one energy source when properly constructed. IHPS configuration, including Diesel Engine Generator (DEG), Photovoltaic (PV) systems, and Battery Storage (BATT) elements, are desirable for islanded systems about price and dependability. IHPS mostly use Renewable Energy Sources (RES) for power production, which is variable. Consequently, these variations often make it difficult for traditional control systems to maximize efficiency across various operating environments. The current research discusses the requirement for more effective frequency control in IHPS by suggesting a Model Reference Adaptive Control-Fuzzy Proportional Integral based Whale Optimization Algorithm (MRAC-FPI-WOA) controller. The proposed controller can efficiently manage a range of disturbances by dynamically adjusting its control techniques. The current research conducts an evaluation study comparing the effectiveness of the suggested MRAC-FPI-WOA controller against FPI-WOA, PI-WOA, and PI-PSO controllers. The key evaluation criteria are the ability to maintain stability in frequency within the IHPS and the effectiveness of power production in the overall system. The results demonstrate the superior performance of the MRAC-FPI-WOA controller across diverse operational scenarios. Notably, during a three-phase fault at Bus2, the MRAC-FPI-WOA controller achieves significant performance enhancements over the PI-PSO controller, with reductions of 59.05% in maximum overshoot (% $$\:{\text{M}}_{\text{p}}$$ ), 72.83% in maximum undershoot (% $$\:{\text{M}}_{\text{u}\text{s}}$$ ), 32.07% in settling time ( $$\:{\text{T}}_{\text{s}}$$ ), and 34.81% in the integral of time-weighted absolute error (ITAE). A similar trend is observed during a three-phase fault at the tie-line, where the MRAC-FPI-WOA controller yields improvements of 57.47% in % $$\:{\text{M}}_{\text{p}}$$ , 79.36% in % $$\:{\text{M}}_{\text{u}\text{s}}$$ , 40.9% in $$\:{\text{T}}_{\text{s}}$$ , and 78.08% in ITAE. Furthermore, the controller exhibits exceptional dynamic responsiveness to ramp variations in solar radiation, substantially reducing % $$\:{\text{M}}_{\text{p}}\:$$ by 96.72%, % $$\:{\text{M}}_{\text{u}\text{s}}$$ by 95.24%, $$\:{\text{T}}_{\text{s}}\:$$ by 22.79%, and ITAE by 89.69%. Additionally, it demonstrates robust adaptability to random solar radiation fluctuations, consistently optimizing transient response with reductions of 96.63% in % $$\:{\text{M}}_{\text{p}}$$ , 99.58% in % $$\:{\text{M}}_{\text{u}\text{s}}$$ , 22.07% in $$\:{\text{T}}_{\text{s}}$$ , and 95.23% in ITAE.

4 December 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SHSamir A. Hamad
Samir A. Hamad
MGMohamed A. Ghalib
Mohamed A. Ghalib
MEMahmoud F. Elmorshedy
Mahmoud F. Elmorshedy
SASulaiman Z. Almutairi
Sulaiman Z. Almutairi
MAMohammed H. Alqahtani
Mohammed H. Alqahtani
HAHazem Hassan Ali
Hazem Hassan Ali
The main difficulties facing the operation of parallel converters in DC microgrids (DCMGs) are load sharing, circulation current, and bus voltage regulation. A droop controller is commonly used to control current sharing among parallel DC–DC converters due to its simplicity. However, the values of droop parameters impact both bus voltage regulation and the error in current sharing among converters. This study introduces an adaptive and straightforward droop control mechanism designed to estimate droop parameters. The algorithm aims to enhance both bus voltage regulation and load sharing performance within DCMGs. Additionally, to mitigate bus voltage deviation in DCMGs, the second loop shifts the droop lines to maintain voltage regulation at rated values. The proposed method has been compared with the conventional droop controller under variable input voltage and load resistance conditions. Simulation results demonstrate that the presented method outperforms the traditional control approach, achieving superior performance.

Verified
Journal Article
Open access
PDF file
MGMohamed A. Ghalib
Mohamed A. Ghalib
SHSamir A Hamad
Samir A Hamad
Mahmoud F. ElmorshedyMahmoud F. Elmorshedy
Mahmoud F. Elmorshedy
DADhafer Almakhles
Dhafer Almakhles
HAHazem Ali
Hazem Ali
There is an increasing interest in achieving global climate change mitigation targets that target environmental protection. Therefore, electric vehicles (as linear metros) were developed to avoid greenhouse gas emissions, which negatively impact the climate. Hence, this paper proposes a finite set-model predictive-based current control (FS-MPCC) strategy of linear induction motor (LIM) for linear metro drives fed by solar cells with a beta maximum power extraction (B-MPE) control approach to achieve lower thrust ripples and eliminate a selection of weighting factors, the main limitation of conventional model predictive-based thrust control (which can be time consuming and challenging). The B-MPE control approach ensures that the solar cells operate at their maximum power output, maximizing the energy harvested from the sun. Considering a single cost function of primary current errors between the predicted values and their references in αβ-axes, the proposed method eliminates the need for weighting factor selection, thus simplifying the control process. A comparison between the conventional and the presented control method is conducted using MATLAB/Simulink under different scenarios. Comprehensive simulation results of the presented system on a 3 kW LIM prototype revealed that the introduced system based on FS-MPCC surpasses the conventional technique, resulting in a maximum power extraction from solar cells and a suppression of the thrust ripples as well as an avoidance of weighting factor tuning, leading to fewer computational steps.