Jieli Li

Dr. Jieli Li

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2024 in Critical Reviews in Clinical Laboratory Sciences
Verified
Journal Article
Open access
RHRongrong Huang
Rongrong Huang
JSJunyan Shi
Junyan Shi
RWRuhan Wei
Ruhan Wei
JLJieli Li
Jieli Li
Insulin-like growth factor 1 (IGF-1), primarily synthesized in the liver, was initially discovered due to its capacity to replicate the metabolic effects of insulin. Subsequently, it emerged as a key regulator of the actions of growth hormone (GH), managing critical processes like cell proliferation, differentiation, and apoptosis. Notably, IGF-1 displays a longer half-life compared to GH, making it less susceptible to factors that may affect GH concentrations. Consequently, the measurement of IGF-1 proves to be more specific and sensitive when diagnosing conditions such as acromegaly or GH deficiency. The recognition of the existence of IGFBPs and their potential to interfere with IGF-1 immunoassays urged the implementation of various techniques to moderate this issue and provide accurate IGF-1 results. Additionally, in response to the limitations associated with IGF-1 immunoassays and the occurrence of discordant IGF-1 results, modern mass spectrometric methods were developed to facilitate the quantification of IGF-1 levels. Taking advantage of their ability to minimize the interference caused by IGF-1 variants, mass spectrometric methods offer the capacity to deliver robust, reliable, and accurate IGF-1 results, relying on the precision of mass measurements. This also enables the potential detection of pathogenic mutations through protein sequence analysis. However, despite the analytical challenges, the discordance in IGF-1 reference intervals can be attributed to a multitude of factors, potentially leading to distinct interpretations of results. The establishment of reference intervals for each assay is a demanding task, and it requires nationwide multicenter collaboration among laboratorians, clinicians, and assay manufacturers to achieve this common goal in a cost-effective and resource-efficient manner. In this comprehensive review, we examine the challenges associated with the standardization of IGF-1 measurement methods, the minimization of pre-analytical factors, and the harmonization of reference intervals. Particular emphasis will be placed on the development of IGF-1 measurement techniques using "top-down" or "bottom-up" mass spectrometric methods.

16 March 2024 in Metabolomics
Verified
Journal Article
Open access
PDF file
RXRui Xu
Rui Xu
SZShiqi Zhang
Shiqi Zhang
JLJieli Li
Jieli Li
JIANGJIANG (Chris) ZhuJIANGJIANG (Chris) Zhu
JIANGJIANG (Chris) Zhu
Introduction: Pre-analytical factors like sex, age, and blood processing methods introduce variability and bias, compromising data integrity, and thus deserve close attention. Objectives: This study aimed to explore the influence of participant characteristics (age and sex) and blood processing methods on the metabolic profile. Method: A Thermo UPLC-TSQ-Quantiva-QQQ Mass Spectrometer was used to analyze 175 metabolites across 9 classes in 208 paired serum and lithium heparin plasma samples from 51 females and 53 males. Results: Comparing paired serum and plasma samples from the same cohort, out of the 13 metabolites that showed significant changes, 4 compounds related to amino acids and derivatives had lower levels in plasma, and 5 other compounds had higher levels in plasma. Sex-based analysis revealed 12 significantly different metabolites, among which most amino acids and derivatives and nitrogen-containing compounds were higher in males, and other compounds were elevated in females. Interestingly, the volcano plot also confirms the similar patterns of amino acids and derivatives higher in males. The age-based analysis suggested that metabolites may undergo substantial alterations during the 25-35-year age range, indicating a potential metabolic turning point associated with the age group. Moreover, a more distinct difference between the 25–35 and above 35 age groups compared to the below 25 and 25–35 age groups was observed, with the most significant compound decreased in the above 35 age groups. Conclusion: These findings may contribute to the development of comprehensive metabolomics analyses with confounding factor-based adjustment and enhance the reliability and interpretability of future large-scale investigations.

14 December 2022 in Clinica Chimica Acta
Verified
Journal Article
Closed access
JLJason K.Y. Lee
Jason K.Y. Lee
KCKendall Cradic
Kendall Cradic
RSRavinder J. Singh
Ravinder J. Singh
JJJoAnna Jones
JoAnna Jones
JLJieli Li
Jieli Li

19 May 2023 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
CFCaroline E Franks
Caroline E Franks
JLJieli Li
Jieli Li
MMMagen Martinez
Magen Martinez
CFChristopher W Farnsworth
Christopher W Farnsworth
PJPatricia M Jones
Patricia M Jones
AGAnn M Gronowski
Ann M Gronowski
Background: The use of quantitative human chorionic gonadotropin (hCG) as a tumor marker is widely accepted despite lack of FDA-approval for oncology. Differences in iso- and glycoform recognition among hCG immunoassays is well established, exhibiting wide inter-method variability. Here, we assess the utility of 5 quantitative hCG immunoassays for use as tumor markers in trophoblastic and non-trophoblastic disease.Methods: Remnant specimens were obtained from 150 patients with gestational trophoblastic disease (GTD), germ cell tumors (GCT), or other malignancies. Specimens were identified by review of results from physician-ordered hCG and tumor marker testing. Five analyzer platforms were used for split specimen analysis of hCG: Abbott Architect Total, Roche cobas STAT, Roche cobas Total, Siemens Dimension Vista Total, and Beckman Access Total.Results: Frequency of elevated hCG concentrations (above reference cutoffs) was highest in GTD (100%), followed by GCT (55% to 57%), and other malignancies (8% to 23%). Overall, the Roche cobas Total detected elevated hCG in the greatest number of specimens (63/150). Detection of elevated hCG in trophoblastic disease was nearly equivalent among all immunoassays (range, 41 to 42/60).Conclusions: While no immunoassay is likely to be perfect in all clinical situations, results for the 5 hCG immunoassays evaluated suggest that all are adequate for use of hCG as a tumor marker in gestational trophoblastic disease and select germ cell tumors. Further harmonization of hCG methods is needed as serial testing for biochemical tumor monitoring must still be performed using a single method. Additional studies are needed to assess the utility of quantitative hCG as a tumor marker in other malignant disease.

19 July 2024 in Endocrine
Verified
Journal Article
Open access
PDF file
JLJieli Li
Jieli Li
MHMaya Hatten-Beck
Maya Hatten-Beck
JLJason K. Y. Lee
Jason K. Y. Lee
AHAndrew Norbert Hoofnagle
Andrew Norbert Hoofnagle
Background: To address the challenges posed by inconsistent detection of analog insulin in commercially available insulin immunoassays, resulting in potential discrepancies in clinical findings and misdiagnosis during the investigation of factitious hypoglycemia., we aimed to evaluate the ability of the Siemens Atellica automated immunoassay to detect insulin analogs compared with LC-MS/MS. Methods: Five insulin analogs were analyzed at 10 ng/mL spiked into serum samples, with recombinant human insulin as positive controls. Insulin and C-peptide assays were performed using Siemens Atellica and LC-MS/MS. Recovery rates were calculated. Results: Siemens Atellica immunoassay demonstrated robust cross-reactivity (92–121%) of insulin analogs. In contrast, glargine was detected by LC-MS/MS but other analogs were not observed (<10% recovery). Conclusion: Our results indicate that the insulin assay conducted on the Siemens Atellica platform could be used to diagnose factitious hypoglycemia by detecting the specific insulin analogs involved. The findings from our studies indicate the suitability of this method for clinical laboratory use in cases where factitious hypoglycemia is under consideration as a potential diagnosis. Clinicians should take these results into account when interpreting insulin measurements, particularly in instances where insulin analog overdose is suspected.

8 June 2023 in Endocrine
Verified
Journal Article
Closed access
PDF file
HAHussam Alkhalaileh
Hussam Alkhalaileh
RWRuhan Wei
Ruhan Wei
JLJason K. Y. Lee
Jason K. Y. Lee
JJJoAnna Jones
JoAnna Jones
JLJieli Li
Jieli Li