Background: Fentanyl is a synthetic opioid associated with illicit drug use and overdose deaths. The SEFRIA Immunalysis (IAL) and ARK fentanyl assays are both FDA-cleared, open channel immunoassays for fentanyl detection in urine. However, limited data are available in the literature comparing these assays. The objective of this study was to perform a direct comparison of these two fentanyl immunoassays. Methods: IAL and ARK fentanyl immunoassays were performed on a Roche Cobas e602 automated chemistry analyzer. Repeatability and total imprecision were compared by diluting fentanyl into urine at concentrations above, below, and at the manufacturers’ cutoffs of 1.0 ng/mL. Cross-reactivity was assessed for norfentanyl and the fentanyl analogs acetylfentanyl, acrylfentanyl, and furanylfentanyl. Concordance was assessed in 90 patient samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS) as the gold standard. Results: Repeatability varied from 11.4%–17.8% on the IAL assay and 2.8%–5.5% on the ARK assay. Total imprecision was 18.9%–40.7% on the IAL assay and 2.9%–6.4% on the ARK assay. Both assays cross-reacted with acetylfentanyl (∼100%), acrylfentanyl (∼100%), and furanylfentanyl (∼20%), but only the ARK assay cross-reacted with norfentanyl (∼3%). An admixture of 0.5 ng/mL fentanyl and 6 ng/mL norfentanyl produced a positive result on the ARK assay. Total concordance between IAL and ARK for 90 tested patient samples was 93% (kappa = 0.85). Relative to LC-MS/MS, the IAL assay had a concordance of 90% (kappa = 0.79) and the ARK assay had a concordance of 94% (kappa = 0.88). Including norfentanyl in the LC-MS/MS confirmation increased the concordance of the ARK to 96% (kappa = 0.90). Conclusions: The ARK assay recognized the metabolite norfentanyl, demonstrated superior precision, and had better concordance with LC-MS/MS compared to the IAL assay.
26 June 2020 in The Journal of Applied Laboratory Medicine
Background: Validation of hospital pneumatic tube systems (PTS) is recommended to predict and prevent errors caused by sample hemolysis. 3-Axis accelerometer dataloggers have been successfully implemented as tools for PTS validation, but the most suitable device for such validation has not been investigated. The aim of this study was to evaluate the performance of four commercially available 3-axis accelerometers for PTS validation. Methods: PCE-VD3 (PCE), CEM DT-178A (CEM), Extech VB300 (EXT), and MSR 145 (MSR) dataloggers were placed into a single PTS carrier and repeatedly transported through one of three PTS routes. The number and magnitude of accelerations within each PTS route was collected by each device. Deming regression analysis was used to compare device performance. Results: The MSR datalogger captured the greatest number of g-forces >3 g, 5 g, 10 g, and 15 g, and the greatest magnitude of g-force (26.7 g) relative to the other devices (CEM: 23.0 g, EXT: 23.3 g, PCE: 23.7 g). As a result of increased sampling frequency, the MSR recorded the lowest AUC and the greatest number of g-forces exceeding 3 g relative to the other devices. Subjectively, the data were difficult to extract from 4 tested devices. Conclusions: Commercially available dataloggers differ in their ability to detect the number and magnitude of g-forces within PTSs. We recommend that one device be used to perform all PTS evaluations, with baseline evaluations for tolerable AUC, number, and magnitude of g-forces established internally. Lack of harmonization, cumbersome data processing, and time-consuming data analysis are substantial barriers to universal implementation of dataloggers for PTS validation and monitoring.
Background: The use of quantitative human chorionic gonadotropin (hCG) as a tumor marker is widely accepted despite lack of FDA-approval for oncology. Differences in iso- and glycoform recognition among hCG immunoassays is well established, exhibiting wide inter-method variability. Here, we assess the utility of 5 quantitative hCG immunoassays for use as tumor markers in trophoblastic and non-trophoblastic disease.Methods: Remnant specimens were obtained from 150 patients with gestational trophoblastic disease (GTD), germ cell tumors (GCT), or other malignancies. Specimens were identified by review of results from physician-ordered hCG and tumor marker testing. Five analyzer platforms were used for split specimen analysis of hCG: Abbott Architect Total, Roche cobas STAT, Roche cobas Total, Siemens Dimension Vista Total, and Beckman Access Total.Results: Frequency of elevated hCG concentrations (above reference cutoffs) was highest in GTD (100%), followed by GCT (55% to 57%), and other malignancies (8% to 23%). Overall, the Roche cobas Total detected elevated hCG in the greatest number of specimens (63/150). Detection of elevated hCG in trophoblastic disease was nearly equivalent among all immunoassays (range, 41 to 42/60).Conclusions: While no immunoassay is likely to be perfect in all clinical situations, results for the 5 hCG immunoassays evaluated suggest that all are adequate for use of hCG as a tumor marker in gestational trophoblastic disease and select germ cell tumors. Further harmonization of hCG methods is needed as serial testing for biochemical tumor monitoring must still be performed using a single method. Additional studies are needed to assess the utility of quantitative hCG as a tumor marker in other malignant disease.