CSong-497 Song

Dr. CSong-497 Song


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2024 in Buildings
Verified
Journal Article
Open access
PDF file
YYYajing Yan
Yajing Yan
CSCSong-497 Song
CSong-497 Song
XPXuan Wu Pan
Xuan Wu Pan
JWJie Wang
Jie Wang
YBYifan Bai
Yifan Bai
The resistance loss and energy consumption when fluid flows through a tee in an HVAC system are severe. To improve energy efficiency and reduce carbon emissions, a novel tee with a U-shaped deflector is proposed, supported by experiments and numerical simulations. The resistance reduction mechanism of the U-shaped deflector was analyzed according to the viscous dissipation principle and the field synergy principle. The resistance reduction of the novel tee with different deflector angles and a traditional tee were compared. The results show that the resistance loss of the tee was mainly due to the flow separation and deformation of the fluid in the main branch. The relationship between the local resistance coefficient and the diameter ratio of the main-branch pipe was exponential, and the relationship between the local resistance coefficient and the diameter ratio of the main straight pipe was linear. The total resistance loss reduction rate of the tee with the addition of a 26° deflector was the highest, reaching 72.4%, the volume-weighted average synergy angle increased by 1°, and the viscous dissipation decreased by 21.7%. This study provides a reference for the resistance reduction design of complex local components such as tees in HVAC systems.

24 January 2024 in Research Square
Verified
Preprint
Open access
PDF file
JWJie Wang
Jie Wang
CSCSong-497 Song
CSong-497 Song
XPXuan Wu Pan
Xuan Wu Pan
YYYajing Yan
Yajing Yan
KZKe Zhao
Ke Zhao
At present, to reduce the energy consumption of buildings and thereby decrease carbon emissions, the research on the internal flow mechanism of local components represented by elbows has been paid more and more attention in heating, cooling and water supply systems. In this paper, the study delves into the mechanisms behind fluid flow pattern changes in elbows, examining factors such as the causes of fluid flow pattern changes, the dynamic mechanisms of uneven pressure distribution, and mechanical properties. Comparative analyses were conducted on the changes in local resistance coefficient, center section velocity, and wall shear stress of elbows under various conditions. The results revealed that, the local resistance coefficients of bending pipes with different pipe diameters do not completely change according to the power function law at the same inlet flow velocity. Further analysis of the mechanical properties and dynamic mechanisms in elbows with these pipe diameters indicates that the observed results are attributed to various factors, including fluid velocity and wall shear stress. It is found that the result is caused by many factors such as fluid velocity and wall shear stress. With the increase of pipe diameter, the influence of the turning section on the fluid decreases, and the curvature effect of the pipe also weakens. This study offers theoretical insights for drag reduction optimization of local components in heating, cooling, and water supply pipelines.

28 November 2025 in Buildings
Verified
Journal Article
Open access
PDF file
HZHuijie Zhang
Huijie Zhang
GSGaoju Song
Gaoju Song
CSCSong-497 Song
CSong-497 Song
XPXuan Wu Pan
Xuan Wu Pan
YWYonghui Wang
Yonghui Wang
YLYonggang Lei
Yonggang Lei
The non-fixed location and intermittent emission of pollution sources are posing significant challenges for industrial ventilation and dust removal. Owing to its energy-saving and emission-reduction advantages, recirculating ventilation has emerged as a critical solution in industrial ventilation. However, the introduction of recirculated air leads to the accumulation of both pollutants and temperature in controlled environments. However, the accumulation situation and control methods within the recirculation air system are still not fully understood, especially for discrete pollution sources. Theoretical models were developed in this paper to quantitatively calculate these issues. Then, the spatiotemporal distributions of air temperature and pollutant concentrations were investigated within the controlled environment by numerical simulation. The result shows that upper limits exist for both pollutant and heat accumulation. Controlling the recirculation air ratio between 0% and 60% resulted in a corresponding increase in pollutant concentration ranging up to 28.58% and a temperature rise of up to 6.16%. At a 27.8% recirculation ratio, fresh air consumption decreased by 27.8%, mean pollutant concentration increased by 5.50%, and mean air temperature rose by 3.78%. In addition, the dynamic characteristics of pollutant concentration and temperature variation at different circulating air ratios were analyzed. The recirculating air system effectively conserves energy and reduces emissions. The quantitative calculation models can facilitate the adoption and promotion of such systems, thereby contributing to industrial green development.

24 May 2026 in Buildings
Verified
Journal Article
Open access
PDF file
LXLiu Xiaozhi
Liu Xiaozhi
CSCSong-497 Song
CSong-497 Song
XPXuan Wu Pan
Xuan Wu Pan
YWYonghui Wang
Yonghui Wang
YLYonggang Lei
Yonggang Lei
Controlling pollutant dispersion in high-rise buildings is crucial for public health. Vertical pollutant diffusion in stairwells occurs under thermal and wind effects. However, most existing studies rely on idealized boundary conditions. To address this, this study uses field-measured wall temperatures and a window wind velocity as boundary conditions for transient CFD simulations. We investigate the vertical diffusion characteristics of buoyant (CH4) and dense (CO2) pollutants under thermal pressure, window velocity, and wind–thermal coupling in a high-rise residential building in Taiyuan. Results show an asymmetric “fast-up, slow-down” diffusion under thermal pressure, a relatively symmetric profile under window velocity, and a hybrid pattern under coupling where the upper region is wind-dominated and the lower region resembles thermal-driven diffusion. Wind–thermal coupling most significantly enhances upward diffusion. Using the arrival time of CH4 at the 28th floor (about 15 m above the source floor) as the benchmark, the diffusion rate under coupling is about 200% faster than under thermal pressure alone, and about 50% faster than under the window-velocity condition alone. Differences in density lead to variations in dispersion, with CH4 exhibiting higher rates, concentrations (2–4 orders greater), and a broader influence range than CO2. This work interprets the synergistic regulatory mechanism between driving forces and pollutant density, providing a theoretical basis for ventilation optimization and pollution control in high-rise buildings.

3 September 2026 in Batteries
Verified
Journal Article
Open access
PDF file
YCYangzhe Chai
Yangzhe Chai
BZBowen Zhang
Bowen Zhang
YLYang Shuang Liang
Yang Shuang Liang
XPXuan Wu Pan
Xuan Wu Pan
YLYonggang Lei
Yonggang Lei
CSCSong-497 Song
CSong-497 Song
Lithium-ion batteries (LIBs) typically operate within a temperature range of 20–50 °C, depending on the chemical composition and application of the battery. Overheating may lead to degradation and thermal runaway, while overcooling may cause lithium plating and internal short circuits. Absorbing heat during the melting of phase-change materials (PCMs) has become an attractive passive thermal management strategy. However, organic PCMs such as paraffin are flammable, and most strategies for improving their inherently low thermal conductivity, such as adding carbon fillers and engineering porous scaffolds, sacrifice latent heat, electrical safety, or cost. Flame retardants achieve flame retardancy at the cost of 15–25% of latent heat, while inorganic PCMs eliminate flammability but introduce undercooling and corrosion. This study synthesizes the PCM–battery thermal management system (BTMS) literature with this safety–performance tension as its organizing principle, covering composite PCM strategies for thermal enhancement, flame-retardant approaches and thermal runaway mitigation, hybrid PCM–active cooling systems, and emerging directions that transcend rather than manage the trade-off. It also identifies the gaps between laboratory demonstration and commercial deployment: durability data measured in hundreds rather than thousands of cycles, absent standardized testing protocols, and manufacturing routes that have not left the university laboratory.