A novel roof solar chimney with wind-induced channel was designed herein to augment indoor natural ventilation under combined action of wind and solar energy. Compared with the traditional solar chimney, the new rooftop solar chimney improves the air flow due to the wind-induced channel. The effects of channel width ratio, chimney inclination at different outdoor wind speeds on the natural ventilation performance of the roof solar chimney were studied by numerical simulation. Finite-volume method was used for the numerical calculation. It was found that the trends of ventilation rate are different when the channel widths increase. The mass flow rate of the new structure increases with the increase in the inclination angle. When the inclination angles increase from 30° to 90°, the ventilation rate increases by 212% for U = 1.0 m·s−1, 166% for U = 2.0 m·s−1, and 127% for U = 3.0 m·s−1 under the condition of and the solar radiation I = 600 W·m−2.
Considering the density variation of compressible fluid, the field synergy principle for compressible laminar flow is presented based on the incompressible flow field synergy principle. The flow resistance is related to the synergy of velocity field and density logarithmic gradient field. Based on the principle of minimum mechanical energy dissipation, the compressible laminar flow field synergy equation is derived. The field synergy principle is verified by an example of the microchannel with expansion cross section, and the structure is optimized. The results indicate that the viscous dissipation value in the entire flow domain of the optimized structure can be reduced by 13.5%, and the angle between the velocity vector and the gradient field of logarithm of density increases. In fluid flows, it will reduce the fluid flow drag to decrease the synergy angle between the velocity vector and the gradient field of logarithm of density.
1 August 2020 in Journal of Pipeline Systems Engineering and Practice
Central heating is the main heating method in cities in northern China in winter, and it is also an important part of urban utilities. The safety of the heating pipe network operation is an important livelihood issue. Temperature fatigue damage of the central heating pipeline has a severe impact on the safe operation of the system, and reasonable estimation of the number of fatigue cycles during the service life of the pipeline is an essential link in the pipeline design of a district heating (DH) system. The temperature data of five typical secondary networks of heat exchanger stations in Jiancao District of Taiyuan City in four heating seasons were collected. The frequency of temperature change during operation was counted, and the maximum total temperature difference cycle number of pipelines was estimated. In this paper, the regression analysis method is adopted to fit the design equation of the number of temperature cycles of water supply and return pipelines in 30 years of service life, which provides a way of thinking for predicting the number of temperature difference fatigue cycles of pipelines in the design stage. In the calculation of the number of maximum total temperature difference cycles, the different values of temperature difference defining parameter and reference temperature difference are analyzed. The results show that the selection of temperature difference defining parameter can effectively distinguish the effect of large and small temperature difference on the number of fatigue cycles of pipelines; at the same time, the cyclic temperature difference is normalized within a specific range of design temperature difference, which overcomes the problem of simplifying the guidance of the operation parameters of the central heating system and makes the predicted maximum total temperature difference cycle have universal guiding significance in a specific heating area.
The study of ventilation air distribution of the building with built-in heat source and set inclined solar chimney is carried out through 3D numerical simulation. The synergistic effect of thermal plume formed by internal heat source and solar chimney effect is analyzed. The effects of different solar radiation intensity I, heat flow density W at the surface of the internal heat source and structural parameters (including the height of the internal heat source from the ground h and the mezzanine inlet spacing b) on the indoor natural ventilation performance of the building are investigated.