Dropper is an important component of pantograph-catenary system employed in high-speed railway. The cyclic stress in dropper can lead to the fatigue failure during operation. The study of the fatigue life of dropper is the premise to ensure the safe exploitation of the train. The analytic vibration equation of dropper is proposed. Based on the finite difference method and MATLAB numerical calculation program, the vibration process and stress variation of the dropper are simulated. The influence of excitation frequency, vibration amplitude, and applied force on fatigue life of dropper is studied, according to the stress history of the dropper, the Basquin equation, and the Palmgren–Miner linear fatigue cumulative damage criterion. The numerical results show that the logarithm of the fatigue life of dropper shows a linear decreasing trend with the increase in the excitation frequency, vibration amplitude, or applied force.
7 February 2023 in Applied Bionics and Biomechanics
This paper aims to explore the construction of an individualized pulmonary artery stenosis model based on computed tomography (CT) images. The stenosis model is simulated using a porous medium, and the numerical simulation is carried out by computational fluid dynamics (CFD) method to discuss non-Newtonian effects on hemodynamics. The hemodynamic parameters and quantitative pulmonary pressure ratio (QPPR) of the right pulmonary artery stenosis are obtained. The change curves of hemodynamic parameters show that the effects of non-Newtonian fluid are more significant than those of Newtonian fluid. Under the non-Newtonian condition, pressure and velocity drop more and faster when blood flow enters into the stenosis region. There is a high wall shear stress in the stenosis downstream. The margin of error between the QPPR value of the non-Newtonian fluid simulation and the clinical measurement value is not more than 10%. This work provides the evidence that the simulation of non-Newtonian fluid is closer to the reality when a porous medium model is used in a stenosis model. This contributes to assessing the severity of pulmonary stenosis behavior and is essential to guide disease treatment.
Background. Compliance mismatch is a negative factor and it needs to be considered in arterial bypass grafting.Objective. A computational model was employed to investigate the effects of arterial compliance mismatch on blood flow, wall stress, and deformation.Methods. The unsteady blood flow was assumed to be laminar, Newtonian, viscous, and incompressible. The vessel wall was assumed to be linear elastic, isotropic, and incompressible. The fluid-wall interaction scheme was constructed using the finite element method.Results. The results show that there are identical wall shear stress waveforms, wall stress, and strain waveforms at different locations. The comparison of the results demonstrates that wall shear stresses and wall strains are higher while wall stresses are lower at the more compliant section. The differences promote the probability of intimal thickening at some locations.Conclusions. The model is effective and gives satisfactory results. It could be extended to all kinds of arteries with complicated geometrical and material factors.
9 March 2021 in Advances in Mechanical Engineering
Dropper is the key component of in a catenary system and it is prone to fatigue fracture. Dropper stress directly affects the operation safety of high-speed railway. In this paper, a span of dropper in a catenary system is modeled to investigate the effects of contact wire tension on dropper stress. The response equation of contact wire and the theoretical equation of dropper stress are deduced. The initial and boundary conditions of each dropper are determined, and then the stress of each dropper is calculated by the finite difference method using a MATLAB program. The results show that the stress amplitude and the maximum tensile stress of the dropper decrease significantly with the increase of contact wire tension. When the tension is low, the stress changes of dropper near the load location experience three stages: instant rebound, attenuated vibration, and bending compression. However, the attenuation vibration stage disappears when the tension is increased to a certain extent. Therefore, the control of the vibration response of the contact wire can effectively reduce the stress amplitude and the maximum tensile stress of the dropper, so as to improve the working reliability of the dropper.
19 January 2021 in Theoretical Biology and Medical Modelling
Background: The effects of arterial wall compliance on blood flow have been revealed using fluid-structure interaction in last decades. However, microcirculation is not considered in previous researches. In fact, microcirculation plays a key role in regulating blood flow. Therefore, it is very necessary to involve microcirculation in arterial hemodynamics.Objective: The main purpose of the present study is to investigate how wall compliance affects the flow characteristics and to establish the comparisons of these flow variables with rigid wall when microcirculation is considered.Methods: We present numerical modeling in arterial hemodynamics incorporating fluid-structure interaction and microcirculation. A novel outlet boundary condition is employed to prescribe microcirculation in an idealised model.Results: The novel finding in this work is that wall compliance under the consideration of microcirculation leads to the increase of wall shear stress in contrast to rigid wall, contrary to the traditional result that wall compliance makes wall shear stress decrease when a constant or time dependent pressure is specified at an outlet.Conclusions: This work provides the valuable study of hemodynamics under physiological and realistic boundary conditions and proves that wall compliance may have a positive impact on wall shear stress based on this model. This methodology in this paper could be used in real model simulations.