Shengnan Wei

Ms. Shengnan Wei


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
DXDanlin Xiao
Danlin Xiao
Junfeng ZhaiJunfeng Zhai
Junfeng Zhai
ZSZhongkai Shen
Zhongkai Shen
QWQiang Wang
Qiang Wang
SWShengnan Wei
Shengnan Wei
Bian ChaoBian Chao
Bian Chao
An electrochemical sensor based on a thin-layer flow cell and a boron-doped diamond (BDD) working electrode was fabricated for heavy metal ions determination using anodic stripping voltammetry. Furthermore, a fluidic automatic detection system was developed. With the wide potential window of the BDD electrode, Zn2+ with high negative stripping potential was detected by this system. Due to the thin-layer and fluidic structure of the sensor system, the electrodepositon efficiency for heavy metal ions were improved without using conventional stirring devices. With a short deposition time of 60 s, the system consumed only 0.75 mL reagent per test. A linear relationship for Zn2+ determination was displayed ranging from 10 μg/L to 150 μg/L with a sensitivity of 0.1218 μA·L·μg−1 and a detection limit of 2.1 μg/L. A high repeatability was indicated from the relative standard deviation of 1.60% for 30 repeated current responses of zinc solution. The system was applied to determine Zn2+ in real water samples by using the standard addition method with the recoveries ranging from 92% to 118%. The system was also used for the simultaneous detection of Zn2+, Cd2+, and Pb2+. The detection results indicate its potential application in on-site monitoring for mutiple heavy metal ions.

1 April 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
SWShengnan Wei
Shengnan Wei
DXDanlin Xiao
Danlin Xiao
YLYang Li
Yang Li
Bian ChaoBian Chao
Bian Chao
This paper describes an electrochemical sensor based on a Cu-modified boron-doped diamond (BDD) electrode for the detection of nitrate-contaminated water. The sensor utilizes the catalytic effect of copper on nitrate and the stability of the BDD electrode. By optimizing the electrolyte system, the linear detection range was expanded, allowing the sensor to detect highly concentrated nitrate samples up to 100 mg/L with a low detection limit of 0.065 mg/L. Additionally, the stability of the sensor was improved. The relative standard deviation of the current responses during 25 consecutive tests was only 1.03%. The wide detection range and high stability of the sensor makes it suitable for field applications and the on-site monitoring of nitrate-contaminated waters.