Yang Li

Dr. Yang Li

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2024 in ACS Omega
Verified
Journal Article
Open access
SWShengnan Wei
Shengnan Wei
DXDanlin Xiao
Danlin Xiao
Bian ChaoBian Chao
Bian Chao
YLYang Li
Yang Li
Phosphorus and nitrogen are important elements in both environmental cycles and biological growth, and their imbalance can lead to serious environmental and biological problems. It is important to be able to monitor the concentration of nitrate and phosphate in the water online. In this paper, a bifunctional boron-doped diamond (BDD) electrode with repeatable electrochemical renewal and modification ability has been developed and used as a shared working electrode for the determination of nitrate and phosphate. First, phosphate can be detected directly with a bare BDD electrode. After a thin copper (Cu) layer was electrodeposited on the BDD electrode, nitrate could be determined. The copper layer is then removed under a positive voltage, and the BDD electrode is renewed and can be used again for phosphate detection. This method enables the detection of both phosphate and nitrate while also improving the stability and repeatability through the renewal of the electrode surface. The segmented linear ranges for phosphate were 0.02-0.4 and 0.4-3 mg/L with a detection limit of 0.004 mg/L. The sensor detected nitrate in a wide concentration range, with segmented linear relationships in the ranges of 0.07-3 and 3-100 mg/L, with a detection limit of 0.065 mg/L. The electrochemical sensor based on the BDD electrode has a good reproducibility for phosphate and nitrate detection. The relative standard deviation (RSD) values of the current responses were 2.98, 2.79, 1.66, 1.81, and 1.23%, respectively, for 35 consecutive tests in 0.05, 0.2, 0.5, 1, and 1.5 mg/L phosphate solution. The RSD values of the current responses were 2.00, 0.97, and 1.03%, respectively, for 25 consecutive tests in 5, 7, and 10 mg/L nitrate solution.

4 March 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
DXDanlin Xiao
Danlin Xiao
Junfeng ZhaiJunfeng Zhai
Junfeng Zhai
ZSZhongkai Shen
Zhongkai Shen
QWQiang Wang
Qiang Wang
SWShengnan Wei
Shengnan Wei
Bian ChaoBian Chao
Bian Chao
An electrochemical sensor based on a thin-layer flow cell and a boron-doped diamond (BDD) working electrode was fabricated for heavy metal ions determination using anodic stripping voltammetry. Furthermore, a fluidic automatic detection system was developed. With the wide potential window of the BDD electrode, Zn2+ with high negative stripping potential was detected by this system. Due to the thin-layer and fluidic structure of the sensor system, the electrodepositon efficiency for heavy metal ions were improved without using conventional stirring devices. With a short deposition time of 60 s, the system consumed only 0.75 mL reagent per test. A linear relationship for Zn2+ determination was displayed ranging from 10 μg/L to 150 μg/L with a sensitivity of 0.1218 μA·L·μg−1 and a detection limit of 2.1 μg/L. A high repeatability was indicated from the relative standard deviation of 1.60% for 30 repeated current responses of zinc solution. The system was applied to determine Zn2+ in real water samples by using the standard addition method with the recoveries ranging from 92% to 118%. The system was also used for the simultaneous detection of Zn2+, Cd2+, and Pb2+. The detection results indicate its potential application in on-site monitoring for mutiple heavy metal ions.

1 April 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
SWShengnan Wei
Shengnan Wei
DXDanlin Xiao
Danlin Xiao
YLYang Li
Yang Li
Bian ChaoBian Chao
Bian Chao
This paper describes an electrochemical sensor based on a Cu-modified boron-doped diamond (BDD) electrode for the detection of nitrate-contaminated water. The sensor utilizes the catalytic effect of copper on nitrate and the stability of the BDD electrode. By optimizing the electrolyte system, the linear detection range was expanded, allowing the sensor to detect highly concentrated nitrate samples up to 100 mg/L with a low detection limit of 0.065 mg/L. Additionally, the stability of the sensor was improved. The relative standard deviation of the current responses during 25 consecutive tests was only 1.03%. The wide detection range and high stability of the sensor makes it suitable for field applications and the on-site monitoring of nitrate-contaminated waters.

13 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
HZHui Zhang
Hui Zhang
YSYu Song
Yu Song
JHJingfang Hu
Jingfang Hu
YLYansheng Li
Yansheng Li
YLYang Li
Yang Li
GGGuowei Gao
Guowei Gao
Optical and synthetic aperture radar (SAR) images exhibit non-negligible intensity differences due to their unique imaging mechanisms, which makes it difficult for classical SIFT-based algorithms to obtain sufficiently correct correspondences when processing the registration of these two types of images. To tackle this problem, an accurate optical and SAR image registration algorithm based on the SIFT algorithm (OS-PSO) is proposed. First, a modified ratio of exponentially weighted averages (MROEWA) operator is introduced to resolve the sudden dark patches in SAR images, thus generating more consistent gradients between optical and SAR images. Next, we innovatively construct the Harris scale space to replace the traditional difference in the Gaussian (DoG) scale space, identify repeatable key-points by searching for local maxima, and perform localization refinement on the identified key-points to improve their accuracy. Immediately after that, the gradient location orientation histogram (GLOH) method is adopted to construct the feature descriptors. Finally, we propose an enhanced matching method. The transformed relation is obtained in the initial matching stage using the nearest neighbor distance ratio (NNDR) and fast sample consensus (FSC) methods. And the re-matching takes into account the location, scale, and main direction of key-points to increase the number of correctly corresponding points. The proposed OS-PSO algorithm has been implemented on the Gaofen and Sentinel series with excellent results. The superior performance of the designed registration system can also be applied in complex scenarios, including urban, suburban, river, farmland, and lake areas, with more efficiency and accuracy than the state-of-the-art methods based on the WHU-OPT-SAR dataset and the BISTU-OPT-SAR dataset.

29 September 2022 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
RZren zhenxing
ren zhenxing
YLYang Li
Yang Li
As one of the most common inorganic ions in daily food and ecological environment, nitrate (NO3−) is potentially harmful to both environment and humans. Therefore, the detection of nitrate concentration is quite important. Chemical sensors, as analytical measurement tools, usually demonstrate high selectivity, fast analysis speed, simple structure, convenient operation, and low cost and are considered to be a promising method for ion identification and detection. In this paper, a miniaturized electrochemical electrode is fabricated based on the microfabrication technology, and an electrochemical sensor for the detection of nitrate concentration in water is developed by combining the deposition technology of nanometal particles with electrochemical analysis technique. The developed electrochemical sensor utilizes electrochemical deposition to prepare a copper (Cu) granular sensitive film with a branch-cluster structure on the surface of a circular working electrode (Pt). Using coppers characteristics of electrocatalytic reduction of NO3− in the acid solution environment (pH=2), the concentration of NO3− in the water sample was calculated by measuring the reduction current on the working electrode when the electrocatalytic reduction reaction of NO3− occurred on the surface of the copper-sensitive membrane. The sensitive film is characterized and detected both with the scanning electron microscope (SEM) and X-ray diffraction analysis (XRD) technique; and the microsensor is used to detect nitrate standard samples; a high detection sensitivity (24.9μA/mmol·L−1) is achieved in the concentration range of 0.0 to 3.0mmol/L. At the same time, a MEMS three-electrode sensor without gold wire bonding and insulating glue packaging is designed, and an automatic detection system is constructed with a STM32f103 microcontroller as the controller to realize the automated detecting process for nitrate ions. At the same time, a distributed system is constructed, which can describe the nitrate concentration in every position of the water area and realize the monitoring of the whole water area. The detection system can meet the working environment under most conditions and has practical significance.

23 April 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
YXYong Xie
Yong Xie
Bian ChaoBian Chao
Bian Chao
MHMingjie Han
Mingjie Han
RWRi Wang
Ri Wang
YLYang Li
Yang Li
SXShanhong Xia
Shanhong Xia
A highly sensitive and accurate dual-signal strategy is developed for trace Cu2+ detection based on the inner filter effect (IFE) between Tween 20-gold nanoparticles (AuNPs) and CdSe/ZnS quantum dots (QDs). Tween 20-AuNPs are utilized as colorimetric probes and excellent fluorescent absorbers. The fluorescence of CdSe/ZnS QDs can be quenched efficiently by Tween 20-AuNPs via IFE. In the presence of D-penicillamine, D-penicillamine induces the aggregation of Tween 20-AuNPs and the fluorescent recovery of CdSe/ZnS QDs at high ionic strength. Upon addition of Cu2+, D-penicillamine tends to selectively chelate with Cu2+ and then forms the mixed-valence complexes, which consequently inhibits the aggregation of Tween 20-AuNPs and the fluorescent recovery. The dual-signal method is used to quantitatively detect trace Cu2+, with low detection limits of 0.57 μg/L and 0.36 μg/L for colorimetry and fluorescence, respectively. In addition, the proposed method using a portable spectrometer is applied to the detection of Cu2+ in water. This sensitive, accurate and miniature sensing system has potential in environmental evaluations.