Giuseppe Scuzzo

Prof. Giuseppe Scuzzo

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2023 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
FSFabrizio Scisciola
Fabrizio Scisciola
MPMario Palone
Mario Palone
GSGiuseppe Scuzzo
Giuseppe Scuzzo
GSGiacomo Scuzzo
Giacomo Scuzzo
LGLuis Tomas Huanca Ghislanzoni
Luis Tomas Huanca Ghislanzoni
LLLuca Lombardo
Luca Lombardo
Objectives: To investigate the accuracy of torque, tip and rotation and linear intra-arch movements yielded by passive self-ligating lingual straight-wire appliances with brackets featuring square slots. Materials and methods: Twenty-five adult Caucasian patients (16 females and 9 males; mean age 26.5 ± 4.3 years) with Class I or mild Class II head-to-head malocclusion were orthodontically treated via passive lingual self-ligating straight-wire appliances (ALIAS, Ormco, Orange, CA) with no extraction. Records were retrospectively analysed, and digital models of pre-treatment (T0), planned (T1) and achieved (T2) phase were acquired for both arches in each patient via an intraoral scanner (Medit I500 (iScan Medit, Seoul, Korea). VAM software (Vectra, Canfield Scientific, Fairfield, NJ, USA) was used to measure both angular values (torque, tip and rotation) and linear intra-arch widths (between canines, first and second premolars and first and second molars). Measurements were obtained for all the movements investigated for each tooth group (incisors, canines, premolars and molars), by arch (maxillary and mandibular) and for both arches at T0, T1 and T2. The accuracy of angular values was compared using Student's t-test against a hypothetical 100%, and among the various tooth groups by post-hoc tests. Transverse linear measurements were investigated by means of the non-parametric Friedman test. The significance threshold was set at 0.05. Results: The mean accuracy of angular values was 77.25 ± 7.71% for torque, 78.41 ± 6.17% for tip and 77.99 ± 6.58% for rotation. In all cases, however, there was a significant difference between planned and achieved movements, and accuracy was significantly lower than the hypothetical 100% for all tooth groups, individual arches and dentition (p < 0.001). For intra-arch diameters, the greatest accuracy values were found for the anterior sectors (83.54 ± 5.19% for the maxillary inter-canine distance) and the lowest for the posterior sectors (67.28% for the maxillary inter-second molar distance). Conclusion: Straight-wire lingual treatment with passive self-ligating appliances featuring with square slot displayed excellent clinical accuracy, albeit with statistical accuracy decreasing antero-posteriorly.

1 February 2010
Verified
Journal Article
Closed access
GSGiuseppe Scuzzo
Giuseppe Scuzzo
KTKyoto Takemoto
Kyoto Takemoto
YTYui Takemoto
Yui Takemoto
ATAya Takemoto
Aya Takemoto
LLLuca Lombardo
Luca Lombardo

1 December 2011
Verified
Journal Article
Closed access
GSGiuseppe Scuzzo
Giuseppe Scuzzo
KTKyoto Takemoto
Kyoto Takemoto
YTYui Takemoto
Yui Takemoto
GSGiacomo Scuzzo
Giacomo Scuzzo
LLLuca Lombardo
Luca Lombardo

1 January 2011
Verified
Journal Article
Closed access
LLLuca Lombardo
Luca Lombardo
AKAndrea Kaplan
Andrea Kaplan
RLRoberto Lapenta
Roberto Lapenta
EBElena Bratti
Elena Bratti
CPClaudia Pera
Claudia Pera
GSGiuseppe Siciliani
Giuseppe Siciliani

30 March 2024 in Oral
Verified
Journal Article
Open access
PDF file
AAAkila Aiyar
Akila Aiyar
GSGiuseppe Scuzzo
Giuseppe Scuzzo
GSGiacomo Scuzzo
Giacomo Scuzzo
Carlalberta VernaCarlalberta Verna
Carlalberta Verna
Background: A range of psychosocial and aesthetic factors motivate patients to undergo orthodontic treatment. The appliance choice depends not only on the type of malocclusion, but also on the aesthetic and functional demands of the patients themselves. Nowadays, digital planning enables the manufacture of individualised and customised orthodontic appliances. However, the predictability of movements with aligner treatment has long been under discussion. This article illustrates, through a series of case reports, how a hybrid approach combining individualised aesthetic orthodontic appliances can improve the predictability of tooth movements, thereby providing additional tools for clinicians charged with choosing the best indicated and biomechanically advantageous technique. To this end, three patients with different malocclusions were treated via a hybrid approach involving clear aligners in the upper arch followed by lingual fixed appliances in the upper and lower arches. All patients were treated using ALIAS lingual PSL 0.018 × 0.018-inch slot brackets and in-house 3D-printed aligners. Findings: The hybrid approach combining aligners and fixed lingual appliances led to the successful resolution of all three complex cases in the series without prolonging treatment time. The superimpositions demonstrate the predictability of even traditionally difficult movements. In particular, the Alias PSL lingual system, used from the beginning, enabled good control of both the torque and inclination of the lower incisors. Conclusions: Combining clear aligners and fixed lingual appliances provides a highly efficient means of treating malocclusions aesthetically. In our cases, the aligners offset the lack of bite-plate effect from the lingual brackets and appliances, providing advantageous biomechanics for rotation correction and control of tip, torque and root movements. Understanding how to exploit the strengths of each appliance enables the clinician to treat adult patients efficaciously, efficiently and aesthetically.

18 August 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
OCOSCAR SUAREZ CASADO
OSCAR SUAREZ CASADO
ALFONSO ALVARADO-LORENZOALFONSO ALVARADO-LORENZO
ALFONSO ALVARADO-LORENZO
Elena Calzadilla SuárezElena Calzadilla Suárez
Elena Calzadilla Suárez
GSGiuseppe Scuzzo
Giuseppe Scuzzo
JVJhonny Leon Valencia
Jhonny Leon Valencia
PGPedro Colino Gallardo
Pedro Colino Gallardo
Aligners represent a therapeutic option in orthodontics, offering advantages such as aesthetics, comfort, and individualized prescriptions for each patient. However, the predictability of maxillary expansion is subject to variability. The objective of this article is to evaluate the efficacy and predictability of aligners in maxillary expansion. One hundred adult patients were included in this study, divided into four groups, each assigned to a different brand of clear aligners: Angel Aligners, Invisalign, Spark, or HeySmile. Digital models were obtained at three stages: initial STL (T1), prediction (T2), and final (T3) (before the first refinement). The models were measured to obtain linear distances between canines, first bicuspids, second bicuspids, and first molars. Statistical analysis was performed using SPSS 28.0. The best predictability was obtained in the lower arch (68.900%) for second bicuspids, while the worst accuracy was for canines (39.290% in the upper arch using Invisalign). Angel aligner showed the highest percentage of predictability (60.002%) among the evaluated brands, followed by HeySmile (59.895%), Spark (59.275%), and Invisalign (57.153%). The results show that clear aligners are an effective treatment for transverse movements in both arches. However, further research is needed to improve predictability.