Simon Gustafsson

Mr. Simon Gustafsson

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Biomacromolecules
Verified
Journal Article
Closed access
KHKai Hua
Kai Hua
IRIgor Rocha
Igor Rocha
PZPeng Zhang
Peng Zhang
SGSimon Gustafsson
Simon Gustafsson
YNYi Ning
Yi Ning
NFNatalia Ferraz
Natalia Ferraz

18 May 2016 in Materials Horizons
Verified
Journal Article
Closed access
PDF file
SGSimon Gustafsson
Simon Gustafsson
PLPascal Lordat
Pascal Lordat
THTobias Hanrieder
Tobias Hanrieder
MAMarcel Asper
Marcel Asper
OSOliver Schaefer
Oliver Schaefer
AMAlbert Mihranyan
Albert Mihranyan
Mille-feuille paper is the first non-woven, wet-laid filter paper, composed of 100% native cellulose, which is capable of removing the “worst-case” model parvoviruses from water with a log10reduction value (LRV) >5 (>99.999%).

18 May 2016 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
SGSimon Gustafsson
Simon Gustafsson
AMAlbert Mihranyan
Albert Mihranyan

5 October 2018 in Membranes
Verified
Journal Article
Open access
PDF file
OGOlof Gustafsson
Olof Gustafsson
SGSimon Gustafsson
Simon Gustafsson
MLManukyan Levon
Manukyan Levon
AMAlbert Mihranyan
Albert Mihranyan
Pressure-dependent breakthrough of nanobioparticles in filtration was observed and it was related to depend on both convective forces due to flow and diffusion as a result of Brownian motion. The aim of this work was to investigate the significance of Brownian motion on nanoparticle and virus capture in a nanocellulose-based virus removal filter paper through theoretical modeling and filtration experiments. Local flow velocities in the pores of the filter paper were modeled through two different approaches (i.e., with the Hagen–Poiseuille equation) and by evaluating the superficial linear flow velocity through the filter. Simulations by solving the Langevin equation for 5 nm gold particles and 28 nm ΦX174 bacteriophages showed that hydrodynamic constraint is favored for larger particles. Filtration of gold nanoparticles showed no difference in retention for the investigated fluxes, as predicted by the modeling of local flow velocities. Filtration of ΦX174 bacteriophages exhibited a higher retention at higher filtration pressure, which was predicted to some extent by the Hagen–Poiseuille equation but not by evaluation of the superficial linear velocity. In all, the hydrodynamic theory was shown able to explain some of the observations during filtration.

3 May 2017 in Langmuir
Verified
Journal Article
Closed access
SGSimon Gustafsson
Simon Gustafsson
MLManukyan Levon
Manukyan Levon
AMAlbert Mihranyan
Albert Mihranyan

11 July 2017 in Optical Materials Express
Verified
Journal Article
Open access
PDF file
GTGopi Krishna Tummala
Gopi Krishna Tummala
NFNadja Felde
Nadja Felde
SGSimon Gustafsson
Simon Gustafsson
ABAdrian Bubholz
Adrian Bubholz
Sven SchröderSven Schröder
Sven Schröder
AMAlbert Mihranyan
Albert Mihranyan
Scattering of ophthalmic devices is a complex phenomenon involving both surface and bulk light-material interactions. In this work, light scattering of nanocellulose reinforced PVA hydrogels contact lenses for ophthalmic applications was investigated. Optical microscopy, fluorescence microscopy and atomic force microscopy (AFM) techniques were used for ultrastructure characterization. Further, 3D angle resolved light scattering measurements in the visible spectral range were performed using a BTDF (bidirectional transmittance distribution function) sensor to quantify the scattered light. Surface and bulk scattering properties were discerned using white light interferometry. Total scatter levels ranging from 3% to 40% were observed depending on the hydrogel composition. The most critical factor affecting the light scattering properties in nanocellulose-reinforced PVA hydrogels was related to the state of hydration of the hydrogels, which is critical to maintain visual acuity of ophthalmic devices.