XIANG HUANG

Dr. XIANG HUANG


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
QZQi Zeng
Qi Zeng
XHXIANG HUANG
XIANG HUANG
SLShuanggao Li
Shuanggao Li
ZDZhengping Deng
Zhengping Deng

17 September 2018 in Sensor Review
Verified
Journal Article
Closed access
ZDZhengping Deng
Zhengping Deng
SLShuanggao Li
Shuanggao Li
XHXIANG HUANG
XIANG HUANG
Purpose: For the measurement of large-scale components in aircraft assembly, the evaluation of coordinate transformation parameters between the coordinate frames of individual measurement systems to the assembly frame is an essential task, which is usually completed by registration of the enhanced reference system (ERS) points. This paper aims to propose an analytical method to evaluate the uncertainties of transformation parameters considering both the measurement error and the deployment error of ERS points. Design/methodology/approach: For each measuring station, the measured coordinates of ERS points are first roughly registered to the assembly coordinate system using the singular value decomposition method. Then, a linear transformation model considering the measurement error and deployment error of ERS points is developed, and the analytical solution of transformation parameters’ uncertainties is derived. Moreover, the covariance matrix of each ERS points in the transformation evaluation is calculated based on a new uncertainty ellipsoid model and variance-covariance propagation law. Findings: For the transformation of both single and multiple measuring stations, the derived uncertainties of transformation parameters by the proposed analytical method are identical to that obtained by the state-of-the-art iterative method, but the solution process is simpler, and the computation expenses are much less. Originality/value: The proposed uncertainty evaluation method would be useful for in-site measurement and optimization of the configuration of ERS points in the design of fixture and large assembly field. It could also be applied to other registration applications with errors on both sides of registration points.

12 March 2018 in Assembly Automation
Verified
Journal Article
Closed access
ZDZhengping Deng
Zhengping Deng
SLShuanggao Li
Shuanggao Li
XHXIANG HUANG
XIANG HUANG
Purpose: In aircraft assembly, standard reference points with nominal coordinates are commonly applied for coordinate transformation between multiple measurement stations and the assembly coordinate system. For several reasons in practical application, these points often fail to envelop the key assembly space, which leads to large transformation uncertainty. This paper aims to analyze and further reduce the coordinate transformation uncertainty by introducing a new hybrid reference system (HRS). Design/methodology/approach: Several temporary extension points without known coordinates are added to enhance the tightness between different stations, especially at the weakness area in the network, thus constituting an HRS together with the existing standard reference points. The coordinate transformation model of the HRS-based measurement network is established based on an extend Gauss–Markov model. By using the geometrical differential property and variance-covariance propagation law, the covariance matrixes in the transformation model are calculated, and the analytical solution of the uncertainties of transformation parameters are ultimately derived. The transformation uncertainty of each check points is presented by Helmert error expression. Findings: The proposed analytical solution of transformation uncertainty is verified using the state-of-the-art Monte Carlo simulation method, but the solution process is simpler and the computation expenses are much less. Practical implications: The HRS with three temporary extension points is practically applied to a tail boom in-site measurement for assembly. The average transformation uncertainty has been reduced by 26 per cent to less than 0.05 mm. Originality/value: The hybrid coordinate transformation model is proposed for the first time. The HRS method for transformation uncertainty reduction is more economical and practical than increasing the number of standard reference points.

27 April 2022 in Measurement Science and Technology
Verified
Journal Article
Closed access
JLJunfeng Liu
Junfeng Liu
XHXiaomei He
Xiaomei He
LZLi Zhang
Li Zhang
XHXIANG HUANG
XIANG HUANG
YWYizhang Wang
Yizhang Wang
The precision measurement of blades has always been a complex problem in free-form surface inspection. For contact inspection of blades by coordinate measuring machine (CMM), the probe radius compensation has a critical influence on the measurement accuracy. In this study, an iterative approach based on the normal vector approximation is proposed to measure the blade profile curve, which aims to reduce the measurement error caused by the conventional method relying on a computer aided design model for compensation. The proposed method combines the local reconstruction of blade surface and CMM measurement software. It first takes the measured results of conventional method as a base, then the resulting corrected points of several sectional profiles are fitted to a B-spline surface to provide an alternative nominal model for CMM software, leading to the next same measurement task. Thus, the measurement-fitting process iterates, in which the current nominal model in CMM software is updated by the reconstructed model of foregoing iteration, until a preset condition is reached. Consequently, the proposed method is implemented on a four-axis CMM, and two blade samples are designed to verify the approach’s effectiveness. Experiments show that our approach is superior to the conventional one in blade profile measurement accuracy.

8 January 2021 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
QZQi Zeng
Qi Zeng
SLShuanggao Li
Shuanggao Li
XHXIANG HUANG
XIANG HUANG

6 April 2022 in Measurement Science and Technology
Verified
Journal Article
Closed access
YPYun Peng
Yun Peng
LHLong Hao
Long Hao
XHXIANG HUANG
XIANG HUANG
SLShuangGao Li
ShuangGao Li
Compared with the traditional assembly simulation based on theoretical models, this paper proposes a new pre-assembly analysis method of aircraft components based on measured data. Specifically, before the actual assembly of the product, digital measurement methods are used to obtain the measured data of the target features of the manufactured parts. Subsequently, the measured data is processed and reconstructed to obtain the actual geometric shape of the part, based on which the product is pre-assembled and analyzed to evaluate the assembly quality in advance. Finally, according to the analysis results, the assembly process is adjusted in time to reduce assembly trial and error and improve assembly quality and efficiency. This article systematically introduces the implementation process of the method, which is illustrated through two cases study on aircraft wing box assembly process. Experimental results demonstrate the feasibility and effectiveness of this proposed method for assembly of large aircraft components.