The rising costs of total knee arthroplasty (TKA) and total hip arthroplasty (THA) have resulted in a substantial economic burden on the U.S. health-care system. Recent efforts to contain these costs have targeted hospital length of stay. However, shorter hospital admissions have raised concerns over possible increases in complications and readmission rates. The purpose of this study was to assess whether early discharge, from 0 to 2 days postoperatively, was associated with increased 30-day major complications and readmissions compared with standard discharge, 3 to 4 days following THA or TKA. The National Surgical Quality Improvement Program (NSQIP) database was queried to identify all patients who underwent an elective, primary unilateral THA or TKA between 2011 and 2012. For each procedure, 2 groups were created consisting of patients discharged from 0 to 2 days (early discharge) and those discharged from 3 to 4 days (standard discharge). Patient demographics and perioperative variables were compared between both discharge groups. Multivariable logistic-regression models were used to assess the independent effect of length of stay on 30-day major-complication and readmission rates. A total of 31,044 patients who underwent TKA and 19,909 patients who underwent THA were included. Overall, patients who were discharged early were younger and had fewer medical comorbidities and a lower American Society of Anesthesiologists (ASA) score. The multivariable logistic-regression model revealed that early discharge was not associated with increased odds of major complications following TKA (odds ratio [OR] = 0.95; 95% confidence interval [CI] = 0.75 to 1.20; p = 0.64). Furthermore, early discharge following THA was found to be an independent predictor against major complications (OR = 0.75; 95% CI = 0.58 to 0.95; p = 0.02). Lastly, early discharge was not an independent risk factor for hospital readmission following THA or TKA. Early discharge was not an independent risk factor for 30-day major complications or readmissions following THA or TKA. Rather, increased major complications and readmissions were attributed to patient comorbidities and perioperative variables. Early discharge within the first 2 days postoperatively for risk-stratified patients appears feasible without compromising patient care. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
1 September 2015 in Journal of Bone and Joint Surgery
Background: To our knowledge, there is currently no validated educational model to evaluate and teach basic arthroscopic skills that is widely accessible to orthopaedic residency training programs. The primary objective was to design and to validate a surgical simulation model by demonstrating that subjects with increasing level of training perform better on basic arthroscopic simulation tasks. The secondary objective was to evaluate inter-rater and intra-rater reliability of the model. Methods: Prospectively recruited participants were divided by level of training into four groups. Subjects performed six basic arthroscopic tasks using a box model: (1) probing, (2) grasping, (3) tissue resection, (4) shaving, (5) tissue liberation and suture-passing, and (6) knot-tying. A score was calculated according to time required to complete each task and deductions for technical errors. A priori total global score, of a possible 100 points, was calculated by averaging scores from all six tasks using equal weights. Results: A total of forty-nine participants were recruited for this study. Participants were grouped by level of training: Group 1 (novice: fifteen medical students and interns), Group 2 (junior residents: twelve postgraduate year-2 or postgraduate year-3 residents), Group 3 (senior residents: sixteen postgraduate year-4 or postgraduate year-5 residents), and Group 4 (six arthroscopic surgeons). The mean total global score (and standard deviation) differed significantly between groups (p < 0.001): 29.0 ± 13.6 points for Group 1, 40.3 ± 12.1 points for Group 2, 57.6 ± 7.4 points for Group 3, and 72.4 ± 3.0 points for Group 4. Pairwise comparison with Tukey correction confirmed construct validity by showing significant improvement in overall performance by increasing level of training between all groups (p < 0.05). The model proved to be highly reliable with an intraclass correlation coefficient of 0.99 for both inter-rater and intra-rater reliability. Conclusions: A simulation model was successfully designed to teach and evaluate basic arthroscopic skills showing good construct validity. This arthroscopic simulation model is inexpensive, valid, and reliable and has the potential to be implemented in other training programs.
Knee kinematics during a drop vertical jump, measured by the Kinect V2 (Microsoft, Redmond, WA, USA), have been shown to be associated with an increased risk of non-contact anterior cruciate ligament injury. The accuracy and reliability of the Microsoft Kinect V2 has yet to be assessed specifically for tracking the coronal and sagittal knee angles of the drop vertical jump. Eleven participants performed three drop vertical jumps that were recorded using both the Kinect V2 and a gold standard motion analysis system (Vicon, Los Angeles, CA, USA). The initial coronal, peak coronal, and peak sagittal angles of the left and right knees were measured by both systems simultaneously. Analysis of the data obtained by the Kinect V2 was performed by our software. The differences in the mean knee angles measured by the Kinect V2 and the Vicon system were non-significant for all parameters except for the peak sagittal angle of the right leg with a difference of 7.74 degrees and a p-value of 0.008. There was excellent agreement between the Kinect V2 and the Vicon system, with intraclass correlation coefficients consistently over 0.75 for all knee angles measured. Visual analysis revealed a moderate frame-to-frame variability for coronal angles measured by the Kinect V2. The Kinect V2 can be used to capture knee coronal and sagittal angles with sufficient accuracy during a drop vertical jump, suggesting that a Kinect-based portable motion analysis system is suitable to screen individuals for the risk of non-contact anterior cruciate ligament injury.
Objectives: Total hip arthroplasty is a successful procedure for treating advanced osteoarthritis (OA). Metal bearing surfaces remain one of the most widely implanted prosthesis, however approximately 10% of patients develop adverse local tissue reactions (ALTRs), namely lymphocytic predominant soft tissue reaction with or without necrosis and osteolysis resulting in high revision rates. The mechanism(s) for these reactions remains unclear although T lymphocyte mediated type IV hypersensitivity to cobalt (Co) and chromium (Cr) ions have been described. The purpose of this study was to determine the prolonged effects of Co and Cr metal ions on synovial fibroblasts to better understand the impact of the synovial membrane in the development of ALTRs. Methods: Human synovial fibroblast-like cells were isolated from donors undergoing arthroplasty. DNA content and Alamar blue assay were used to determine cellular viability against exposure to Co and Cr. A betagalactosidase assay was used to determine the development of cellular senescence. Western blotting and RTqPCR were employed to determine changes in senescent associated secretory factors, signaling and antioxidant enzyme expression. A fluorescent assay was used to measure accumulation of hydrogen peroxide. Results: We demonstrate that prolonged cobalt exposure results in a downregulation of the enzyme catalase resulting in cytosolic accumulation of hydrogen peroxide, decreased Akt activity and cellular senescence. Senescent fibroblasts demonstrated upregulation of proinflammatory cytokines IL-1 beta and TNF alpha in addition to the neurotrophic factor NGF. Conclusion: Our results provide evidence that metal ions induce a senescent associated secretory phenotype in synovial fibroblasts that could contribute to the development of adverse local tissue reactions.