Kittiwoot Sutthivirode

Dr. Kittiwoot Sutthivirode


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2024 in Energies
Verified
Journal Article
Open access
PDF file
SJSuparat Jamsawang
Suparat Jamsawang
SCSaharat Chanthanumataporn
Saharat Chanthanumataporn
KSKittiwoot Sutthivirode
Kittiwoot Sutthivirode
TTTongchana Thongtip
Tongchana Thongtip
This study proposes a simulation technique for investigating a battery thermal management system based on direct refrigerant cooling (BTMS-DRC). The main focus is to investigate the temperature uniformity and working temperature of the module housing. The simulation technique employs a finite element method for a combined conduction–convection heat transfer to predict the module housing temperature. The refrigerant side is based on two-phase flow evaporation, which is represented by the convection heat transfer under a certain refrigerant saturation temperature. The real BTMS-DRC, which is based on the dual-evaporator vapor compression refrigeration system, is constructed for experimentation with the test bench. The simulated result is validated with the experimental results to ensure correction of the modelling. Error rates of approximately 2.9–7.2% are noted throughout the specified working conditions. The BTMS can produce temperatures of less than 35 °C under conditions where 80–320 W heat is generated. The difference in the temperature of the module is around 1.7–4.2 °C. This study also investigates the impact of heat generation, the convection heat transfer coefficient (href), the refrigerant saturation temperature, and thermal conductivity on the module’s temperature. The thermal conductivity ranges from 25 to 430 W/m·K, while the href ranges from 80 to 400 W/m2·K.

27 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
CPChotiwut Prasopsuk
Chotiwut Prasopsuk
KSKittiwoot Sutthivirode
Kittiwoot Sutthivirode
TTTongchana Thongtip
Tongchana Thongtip
This paper reports the improved thermal and drying performance of a solar air heater powered by real solar irradiance and equipped with a tree-like fractal-based cylindrical pin (SAH-TFCP) as a turbulator for drying applications. The main purpose of this work is to demonstrate the SAH-TFCP’s improvement potential based on its thermal and drying performance as compared with a conventional solar air heater based on a flat-plate absorber (SAH-FP). The test was implemented based on solar time from 8:30 to 17:30 under Thailand’s climatic conditions at a latitude angle of 14° and a longitude angle of 100°. Turmeric slices were used to evaluate the SAH’s drying performance. The thermal efficiency, moisture content wet basis (MCwb), drying rate (DR), and drying efficiency were measured as parameters of interest to assess the improvement potential of the SAH-TFCP over the SAH-FP. The results indicate that the SAH-TFCP provides better thermal and drying performance than the SAH-FP. A higher flow rate yields a higher thermal efficiency and a greater improvement potential. The improvement potential is around 44–85%. The drying efficiency of the SAH-TFCP is always higher than that of the SAH-FP and has an improvement potential of 32–44%, depending on the airflow rate.

8 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
Wichean SingmaiWichean Singmai
Wichean Singmai
PJPichet Janpla
Pichet Janpla
KSKittiwoot Sutthivirode
Kittiwoot Sutthivirode
TTTongchana Thongtip
Tongchana Thongtip
NRNatthawut Ruangtrakoon
Natthawut Ruangtrakoon
This paper proposes an energy, exergy, economic, and exergoeconomic (4E) analysis of an Organic Rankine Cycle (ORC) enhanced by an ejector refrigeration system. The two systems are combined via an intercooler, where the unwanted heat is transferred to the ejector cooling loop. The major objective is to reduce the discharge pressure of the expander so that higher power is achieved. However, the combined system requires more equipment and energy input, and, hence, 4E analysis is an efficient tool for assessing the feasibility of it in practical use based on a comprehensive analysis. This study aims to provide a systematic 4E-based evaluation of an ORC integrated with an ejector cooling cycle under realistic tropical conditions. The innovation of this work lies in combining unified thermodynamic, economic, and exergoeconomic assessments to quantify both performance enhancement and cost interactions attributable to condenser-side cooling. The findings offer significant insights into the dominant thermal–economic trade-offs, identify key cost drivers within the ORC + ECC configuration, and highlight operating conditions that maximize the power output and minimize the electricity generation cost. These results contribute practical guidelines for improving the feasibility and deployment of ORC–ejector systems for low-grade heat recovery applications. A theoretical model is formulated to examine both energy and exergy performance indicators together with key economic metrics. Parametric investigations are conducted to investigate the effects of the intercooler temperature (16–22 °C) and generator temperature (70–85 °C) on overall system performance. It is found that the integration of an ejector cooling cycle (ORC + ECC) can significantly enhance the thermo-economic potential of waste heat power generation systems compared to a standard ORC, from both exergoeconomic and LCOE perspectives. The exergoeconomic analysis identified that, while the expander dominates the cost of the standard ORC, the condenser and cooling tower become critical components of the ORC + ECC due to their high exergy-destruction costs. At the system level, the LCOE results confirm that the ORC + ECC can achieve 37–38% lower electricity generation costs compared to the standard ORC.

26 December 2025 in Thermo
Verified
Journal Article
Open access
PDF file
Wichean SingmaiWichean Singmai
Wichean Singmai
PJPichet Janpla
Pichet Janpla
SJSuparat Jamsawang
Suparat Jamsawang
KSKittiwoot Sutthivirode
Kittiwoot Sutthivirode
TTTongchana Thongtip
Tongchana Thongtip
This work proposes the design, construction, and field test of a vacuum seawater desalination system (VSDS) driven by an evacuated tube solar collector (with a total absorption area of 1.86 m2) under tropical climatic condition (Thailand ambient at latitude 13°43′06.0″ N, longitude 100°32′25.4″ E). The VSDS prototype was designed and constructed to be driven by hot water, which is produced by two heat source conditions: (1) an electric heater for laboratory tests and (2) an evacuated tube solar collector for field tests under real climatic conditions. A comparative experimental study to assess the ability to produce fresh water between a conventional dripping/pipe feed column and spray falling film column is proposed in the first part of the discussion. This is to demonstrate the advantage of the spray falling film distillation column. The experimental method is implemented based on the batch system, in which the cycle time (distillation time) considered is 10–20 min so that heat loss via the concentrated seawater blow down is minimized. Later, the field test with solar irradiance under real climatic conditions is demonstrated to assess the freshwater yield and the system performance. The aim is to provide evidence of the proposed vacuum desalination system in real operation. It is found experimentally that the VSDS working with spray falling film provides better performance than the dripping/pipe feed column under the specified working conditions. The spray falling film column can increase the distillated freshwater volume from 1.33 to 2.16 L under identical cycle time and working conditions. The improvement potential is up to 62.4%. The overall thermal efficiency can be increased from 33.7 to 70.8% (improvement of 110.1%). Therefore, the VSDS working with spray falling film is selected for implementing field tests based on real solar irradiance powered by an evacuated tube solar collector. The ability to produce fresh water is assessed, and the overall performance via the average distillation rate and the thermal efficiency (or Gain Output Ratio) is discussed with the real solar irradiance. It is found from the field test with solar time (8.00–16.00) that the VSDS can produce a daily freshwater yield of up to 4.5 L with a thermal efficiency of up to 19%. The freshwater production meets the requirement for international standard drinking water criteria, indicating suitability for household/community use in tropical regions. This work demonstrates the feasibility of VSDS working under real solar irradiance as an alternative technology for sustainable fresh water.

7 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
KSKittiwoot Sutthivirode
Kittiwoot Sutthivirode
TTTongchana Thongtip
Tongchana Thongtip
An experimental determination of optimal performance of a steam ejector refrigerator was proposed which aims to indicate the optimal performance under various heat source temperatures. A small-scale steam ejector refrigerator test bench was constructed to carry out the experiment and to determine the optimal performance map. Three primary nozzles with throat diameters of 1.4, 1.6, and 1.8 mm, were tested with an ejector throat diameter of 14.5 mm, providing the ejector area ratios of 107, 82, and 65, respectively. For a particular working condition, the boiler temperature was varied to determine the maximum COP which is recognized as the optimal operation. It was found that the secondary fluid stream is first choked at the optimal boiler temperature. This optimal point varied significantly with the evaporator temperature, condenser pressure, and ejector area ratios. It was found that this steam ejector refrigerator could be operated under the optimal boiler temperature between 102.5 and 117.5 °C depending on the ejector area ratio, evaporator temperature, and condenser pressure. The optimal performance map is beneficial to further control the heat source temperature so that the maximum COP is achieved.

7 December 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
SJSuparat Jamsawang
Suparat Jamsawang
SCSaharat Chanthanumataporn
Saharat Chanthanumataporn
KSKittiwoot Sutthivirode
Kittiwoot Sutthivirode
TTTongchana Thongtip
Tongchana Thongtip
This paper proposes a simulation technique for investigating the battery thermal management system based direct refrigerant cooling (BTMS-DRC). It employs finite element method for a combined-conduction-convection heat transfer to predict the module temperature and to prove the temperature uniformity. The refrigerant side cooling is based on the two-phase flow evaporation which is represented by the convection heat transfer (flow evaporation) under a certain refrigerant saturation temperature. The battery heat generation is modeled as the constant heat flux. The main module is modeled as the conduction heat transfer. The real BTMS-DRC is constructed for experimentation with the test bench which is based on the dual-evaporators vapour compression refrigeration system. The simulated result is validated with the experimental results to ensure the correction of the modelling. The simulation also investigates the impact of the heat generation, convection heat transfer coefficient, refrigerant saturation temperature, and thermal conductivity on the module temperature and temperature uniformity. It is found that the simulated results agree well with the experimental results. The errors are around 2.9 - 7.2% throughout the specified working conditions. Overall, the proposed technique can be used as a design tool for further developing the BTMS-DRC.