Fabien Billuart

Prof. Fabien Billuart


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2022 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
LMLucas Martinez
Lucas Martinez
NNNathalie Noé
Nathalie Noé
JBJulien Beldame
Julien Beldame
JMJean Matsoukis
Jean Matsoukis
TPThomas Poirier
Thomas Poirier
FBFabien Billuart
Fabien Billuart

17 December 2022 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
MLMatthieu Lalevée
Matthieu Lalevée
LMLucas Martinez
Lucas Martinez
BRBenjamin Rey
Benjamin Rey
JBJulien Beldame
Julien Beldame
JMJean Matsoukis
Jean Matsoukis
FBFabien Billuart
Fabien Billuart

16 August 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
RSRiccardo Sacco
Riccardo Sacco
MMMarie-Aude MUNOZ
Marie-Aude MUNOZ
FBFabien Billuart
Fabien Billuart
MLMatthieu Lalevée
Matthieu Lalevée
JBJulien Beldame
Julien Beldame
Background: Our objective was to conduct a comprehensive analysis of the reproducibility of foot and ankle anthropometric measurements with a three-dimensional (3D) optical scanner. Methods: We evaluated thirty-nine different anthropometric parameters obtained with a 3D Laser UPOD-S Full-Foot Scanner in a healthy population of twenty subjects. We determined the variance of the measurements for each foot/ankle, and the average variance among different subjects. Results: For 40 feet and ankles (15 women and 5 men; mean age 35.62 +/− 9.54 years, range 9–75 years), the average variance was 1.4 ± 2 (range 0.1 to 8). Overall, the mean absolute measurement error was <1 mm, with a maximum variance percentage of 8.3%. Forefoot and midfoot circumferences had a low variance <2.5, with variance percentages <1%. Hindfoot circumferences, malleolar heights, and the length of the first and fifth metatarsal to the ground contact points showed the highest variance (range 1 to 7). Conclusions: The UPOD-S Full-Foot optical Scanner achieved a good reproducibility in a large set of foot and ankle anthropometric measurements. It is a valuable tool for clinical and research purposes.

1 February 2022 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
LMLucas Martinez
Lucas Martinez
NNNathalie Noé
Nathalie Noé
HSHermann Simon
Hermann Simon
JBJulien Beldame
Julien Beldame
JMJean Matsoukis
Jean Matsoukis
FBFabien Billuart
Fabien Billuart

21 March 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
LMLucas Martinez
Lucas Martinez
MLMatthieu Lalevée
Matthieu Lalevée
TPThomas Poirier
Thomas Poirier
HBHelena Brunel
Helena Brunel
JMJean Matsoukis
Jean Matsoukis
FBFabien Billuart
Fabien Billuart
Accurate estimation of hip joint center (HJC) position is crucial during gait analysis. HJC is obtained with predictive or functional methods. But in the functional method, there is no consensus on where to place the skin markers and which combination to use. The objective of this study was to analyze how different combinations of skin markers affect the estimation of HJC position relative to predictive methods. Forty-one healthy volunteers were included in this study; thirteen markers were placed on the pelvis and hip of each subject’s lower limbs. Various marker combinations were used to determine the HJC position based on ten calibration movement trials, captured by a motion capture system. The estimated HJC position for each combination was evaluated by focusing on the range and standard deviation of the mean norm values of HJC and the mean X, Y, Z coordinates of HJC for each limb. The combinations that produced the best estimates incorporated the markers on the pelvis and on proximal and easily identifiable muscles, with results close to predictive methods. The combination that excluded the markers on the pelvis was not robust in estimating the HJC position.

12 July 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
RSRiccardo Sacco
Riccardo Sacco
MMMarie-Aude MUNOZ
Marie-Aude MUNOZ
MLMatthieu Lalevée
Matthieu Lalevée
FBFabien Billuart
Fabien Billuart
JBJulien Beldame
Julien Beldame
Background: Our objective was to conduct a comprehensive analysis of the reproducibility of foot and ankle anthropometric measurements with a three-dimensional (3D) optical scanner. Methods: We evaluated thirty-nine different anthropometric parameters obtained with 3D Laser UPOD-S Full-Foot Scanner in a healthy population of twenty subjects. We determined the variance of the measurements for each foot/ankle, and the average variance among different subjects. Results: For 40 feet and ankles (15 women and 5 men; mean age 35.62 +/- 9.54 years, range 9-75 years), the average variance was 1.4 ± 2 (range 0,1 to 8). Overall, the mean absolute measurement error was < 1 mm, with a maximum variance percentage of 8.3%. Forefoot and midfoot circumferences had a low variance < 2.5, with variance percentages < 1%. Hindfoot circumferences, malleolar heights, and the length of the first and fifth metatarsal to the ground contact points showed the highest variance (range 1 to 7). Conclusion: This optical scanner achieved a good reproducibility of a large set of foot and ankle anthropometric measurements. It is a valuable tool for clinical and research purposes.