Riccardo Sacco

Dr. Riccardo Sacco

Clinique du Val d'Or, Paris, Île-de-France, France
+1
orcid
Chirurgien Orthopédiste, Conventionné Secteur 2 Prothèse ha...

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2025 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
RSRiccardo Sacco
Riccardo Sacco
ATAndrea Tecame
Andrea Tecame
MLMatthieu Lalevée
Matthieu Lalevée
APAntoine Perrier
Antoine Perrier
EMEdward Massa
Edward Massa
PAPaolo Adravanti
Paolo Adravanti
Purpose: Randomised controlled trials (RCTs) comparing robotic‐assisted (RA‐TKA) and conventional total knee arthroplasty (C‐TKA) have demonstrated evolving trends in alignment strategies, surgical workflows and outcomes measurements. This review synthesises current evidence to clarify the evolving role of RA‐TKA over the past two decades. Methods: A PRISMA systematic review was conducted searching PubMed, Cochrane Library, and Google Scholar (2000–2024). Eligible studies were Level I RCTs comparing RA‐TKA to C‐TKA with well‐defined alignment strategies and surgical workflows. Data included demographics, robotic and prosthetic systems, learning curves, outcome measures and complications. Results: From 850 records, 9 RCTs were included (627 TKAs: 317 RA‐TKA, 310 C‐TKA). Patients averaged 66.9 years, BMI 28.1 kg/m², 27.9% male, 69.7 knees, follow‐up 23.7 months. Coronal deformity was predominantly varus (<10°). Robotic systems included Robodoc, Mako, and Navio using cruciate‐retaining or posterior‐stabilised prostheses. All earlier studies followed mechanical alignment (MA); after 2021 all RA‐TKAs adopted personalised alignment strategies. Patellar management varied widely, with no RA‐TKA workflow addressing the patellofemoral space. Most procedures were performed by one or two experienced surgeons; learning curves were only noted in early MA studies. RA‐TKA reduced alignment outliers by 10%–24% ( p < 0.05) versus C‐TKA regardless of the alignment strategy, with no significant difference in functional scores (WOMAC, HSS, KSS, OKS and FJS), range of motion or complications. Recent trials increasingly assessed inflammatory markers, periarticular tissue injury, and quality‐of‐life outcomes. Conclusions: Over the past two decades, RA‐TKA has evolved substantially, transitioning from purely bone‐cutting technology to decision‐making platforms enabling alignment personalisation and dynamic soft‐tissue assessment, improving surgical precision regardless of alignment strategy. Clinical superiority over C‐TKA remains inconclusive in relatively low‐risk patients, predominantly older females with varus deformity, highlighting the need for studies with more diverse populations, prosthetic design, long‐term follow‐up, patient‐specific outcomes, standardised workflow and learning curve reporting, and patellofemoral space optimisation. Level of Evidence: Level I, systematic review of non‐homogeneous RCTs.

3 May 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
JBJulien Beldame
Julien Beldame
RSRiccardo Sacco
Riccardo Sacco
MMMarie-Aude MUNOZ
Marie-Aude MUNOZ
MMMarion Masse
Marion Masse
MLMatthieu Lalevée
Matthieu Lalevée
Background: To prospectively evaluate the reliability of a portable optical scanner compared to the water displacement technique for volumetric measurements of the foot and ankle and to compare the acquisition time associated with these two methods. Methods: Foot volume was measured in 29 healthy volunteers (58 feet, 24 females and 5 males) by a 3D scanner (UPOD-S 3D Laser Full-Foot Scanner®) and by water displacement volumetry. Measurements were performed on both feet, up to a height of 10 cm above the ground. The acquisition time for each method was evaluated. The Kolmogorov-Smirnov test, Lin’s Concordance Correlation Coefficient, and a Student’s t-test were performed. Results: Mean foot volume was 869.7 +/− 165.1 cm3 (3D scanner) versus 867.9 +/− 155.4 cm3 (water-displacement volumetry) (p < 10−5). The concordance of measurements was 0.93, indicative of a high correlation between the two techniques. Volumes were 47.8 cm3 lower when using the 3D scanner versus water volumetry. After statistically correcting this underestimation, the concordance was improved (0.98, residual bias = −0.03 +/− 35.1 cm3). The mean examination time was 4.2 +/− 1.7 min (3D optical scanner) versus 11.1 +/− 2.9 min (water volumeter) (p < 10−4). Conclusions: Ankle/foot volumetric measurements performed using this portable 3D scanner are reliable and fast and can be used in clinical practice and research.

16 August 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
RSRiccardo Sacco
Riccardo Sacco
MMMarie-Aude MUNOZ
Marie-Aude MUNOZ
FBFabien Billuart
Fabien Billuart
MLMatthieu Lalevée
Matthieu Lalevée
JBJulien Beldame
Julien Beldame
Background: Our objective was to conduct a comprehensive analysis of the reproducibility of foot and ankle anthropometric measurements with a three-dimensional (3D) optical scanner. Methods: We evaluated thirty-nine different anthropometric parameters obtained with a 3D Laser UPOD-S Full-Foot Scanner in a healthy population of twenty subjects. We determined the variance of the measurements for each foot/ankle, and the average variance among different subjects. Results: For 40 feet and ankles (15 women and 5 men; mean age 35.62 +/− 9.54 years, range 9–75 years), the average variance was 1.4 ± 2 (range 0.1 to 8). Overall, the mean absolute measurement error was <1 mm, with a maximum variance percentage of 8.3%. Forefoot and midfoot circumferences had a low variance <2.5, with variance percentages <1%. Hindfoot circumferences, malleolar heights, and the length of the first and fifth metatarsal to the ground contact points showed the highest variance (range 1 to 7). Conclusions: The UPOD-S Full-Foot optical Scanner achieved a good reproducibility in a large set of foot and ankle anthropometric measurements. It is a valuable tool for clinical and research purposes.

7 November 2022 in Surgical Oncology
Verified
Journal Article
Closed access
RSRiccardo Sacco
Riccardo Sacco
MLMatthieu Lalevée
Matthieu Lalevée
PPPietro Pellegrino
Pietro Pellegrino
AFAndrea Ferro
Andrea Ferro
BYBendoukha Yasmine
Bendoukha Yasmine
FDFranck Dujardin
Franck Dujardin

27 June 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
JCJean-Yves Coillard
Jean-Yves Coillard
RRRomain REY
Romain REY
ACAlessandro Civinini
Alessandro Civinini
FBFabien Billuart
Fabien Billuart
ESEli Schmidt
Eli Schmidt
MLMatthieu Lalevée
Matthieu Lalevée
Background: The outcomes of first metatarsal (M1) distal osteotomies in hallux valgus (HV) can be improved, especially for intermetatarsal angle (IMA) correction, which is mainly based on lateral displacement of the M1 head (i.e., translation) through the osteotomy. Conversely, there is a spontaneous reduction in the IMA in first metatarsophalangeal joint (MTP1) arthrodesis. But we do not know whether this can be applied to distal osteotomies. We propose a distal osteotomy, called 3D chevron, which combines supination and varization of the M1 head. This might realign soft tissues around the MTP1, potentially leading to a spontaneous reduction in the IMA by an analogous mechanism to MTP1 fusion. Therefore, our study aimed to assess whether spontaneous reductions in IMAs exist in distal M1 osteotomies in the absence of lateral translations of M1 heads. Methods: A prospective continuous series of 25 3D chevrons was performed. Two groups were formed during surgery. Patients requiring no M1 head lateral displacement were included in the “successful correction without translation” group, and patients requiring M1 head lateral displacement were included in the “failed correction without translation” group. Radiographic analysis was performed preoperatively and at 1 year postoperatively. Results: Twenty-two women and three men, with a mean age of 44.8 ± 14.2 years and a mean body mass index of 22.6 ± 4.1 kg/m2, underwent follow-up at one year after surgery. The “successful correction without translation” group was composed of HV with milder deformities (13/25 HVs, median preoperative IMA = 13 (IQR 2)) compared to the “failed correction without translation” group (median IMA = 16 (IQR 2.25) p < 0.001). Spontaneous reductions in IMAs were observed in the “successful correction without translation” group, with a median decrease in the IMA of 6 degrees (CI95%[5.5; 8.0]; p < 0.001) between preoperative and 1-year radiographs. Conclusion: Distal osteotomies allow for spontaneous reduction in the IMA in HV. First metatarsal head translation through an osteotomy should not be considered as the only procedure to correct IMAs in distal osteotomies.

20 May 2022 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
RSRiccardo Sacco
Riccardo Sacco
MBMichel Bonnevalle
Michel Bonnevalle
ENEric Nectoux
Eric Nectoux
DFDamien Fron
Damien Fron
MOMourad Ould-Slimane
Mourad Ould-Slimane
Federico CanaveseFederico Canavese
Federico Canavese