ALİ HAKİM REYHAN

Dr. ALİ HAKİM REYHAN

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
ÇMÇağrı Mutaf
Çağrı Mutaf
İUİrfan Uzun
İrfan Uzun
FYFunda Yüksekyayla
Funda Yüksekyayla
Background: This study evaluates the ability of six popular chatbots; ChatGPT-3.5, ChatGPT-4.0, Gemini, Copilot, Chatsonic, and Perplexity, to provide reliable answers to questions concerning keratoconus. Methods: Chatbots responses were assessed using mDISCERN (range: 15–75) and Global Quality Score (GQS) (range: 1–5) metrics. Readability was evaluated using nine validated readability assessments. We also addressed the quality and accountability of websites from which the questions originated. Results: We analyzed 20 websites, 65% “Private practice or independent user” and 35% “Official patient education materials”. The mean JAMA benchmark score was 1.40 ± 0.91 (0–4 points), indicating low accountability. Reliability, measured using mDISCERN, ranged from 42.91 ± 3.15 (ChatGPT-3.5) to 46.95 ± 3.53 (Copilot). The most frequent question was “What is keratoconus?” with 70% of websites providing relevant information. This received the highest mDISCERN score (49.30 ± 4.91) and a relatively high GQS score (3.40 ± 0.56) with an Automated Readability Level Calculator score of 13.17 ± 2.13. Moderate positive correlations were determined between the website numbers and both mDISCERN (r = 0.265, p = 0.25) and GQS (r = 0.453, p = 0.05) scores. The quality of information, assessed using the GQS, ranged from 3.02 ± 0.55 (ChatGPT-3.5) to 3.31 ± 0.64 (Gemini) (p = 0.34). The differences between the texts were statistically significant. Gemini emerged as the easiest to read, while ChatGPT-3.5 and Perplexity were the most difficult. Based on mDISCERN scores, Gemini and Copilot exhibited the highest percentage of responses in the “good” range (51–62 points). For the GQS, the Gemini model exhibited the highest percentage of responses in the “good” quality range with 40% of its responses scoring 4–5. Conclusions: While all chatbots performed well, Gemini and Copilot showed better reliability and quality. However, their readability often exceeded recommended levels. Continuous improvements are essential to match information with patients’ health literacy for effective use in ophthalmology.

25 September 2021 in Indian Journal Of Ophthalmology
Verified
Journal Article
Open access
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
AKAyşe Sevgi Karadağ
Ayşe Sevgi Karadağ
ŞÇŞerife Şule Çınar
Şerife Şule Çınar
Purpose: It was aimed to compare the levels of inflammation-related parameters, such as neutrophil/lymphocyte ratio (NLR) and platelet/lymphocyte ratio (PLR), in patients with advanced keratoconus (KC) and healthy controls. Also, we evaluated the relationships between these parameters and several corneal topography values used in the KC diagnostic index. Methods: Forty patients with advanced and 40 healthy volunteers were included in this study. In the KC group, 20 patients were nonprogressive KC and 20 patients were progressive KC. In all participating individuals, we evaluated detailed ophthalmologic examination findings and complete blood count data, while corneal topographic measurements were also recorded in patients with KC. Results: The mean NLR value was 2.3 ± 1.19 in the progressive KC group; nonprogressive KC values were 1.99 ± 1.69 and 1.81 ± 0.72 in the control group. Mean PLR value was 113.24 ± 48.44 in the progressive KC group, nonprogressive KC values were 96.47 ± 31.04 and 104.09 ± 35.14 in the control group. No statistically significant difference was found between patients with progressive KC, nonprogressive KC, and healthy volunteers in terms of mean NLR and PLR values (P > 0.05). NLR values were found to demonstrate significant positive correlations with the corneal topography parameters, Symmetry Index front (r = 0.278, P = 0.025), KC Vertex front (r = 0.247, P = 0.048), and Baiocchi Calossi Versaci front (r = 0.273, P = 0.028); there was no significant relationship between corneal topography parameters and PLR values. Conclusion: Although there was no significant difference between the progressive KC, nonprogressive KC, and control groups in inflammation parameters such as NLR and PLR, a positive correlation was observed between the NLR value and some corneal topography findings used in the diagnosis of KC. The role of inflammation in the etiology of KC can be better understood by clinical studies and laboratory tests conducted with prospective studies involving a higher number of patients.

5 September 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
ÇMÇağrı Mutaf
Çağrı Mutaf
İUİrfan Uzun
İrfan Uzun
FYFunda Yüksekyayla
Funda Yüksekyayla
This study evaluates the ability of six popular chatbots; ChatGPT-3.5, ChatGPT-4.0, Gemini, Copilot, Chatsonic, and Perplexity to provide reliable answers to questions concerning keratoconus. Methods: Chatbots responses were assessed using mDISCERN and Global Quality Score (GQS) metrics. Readability was evaluated using nine validated readability assessments. We also addressed the quality and accountability of websites from which the questions originated. Results: We analyzed 20 websites, 65% "Private practice or independent user" and 35% "Official patient education materials." The mean JAMA Benchmark score was 1.5±0.68, indicating low accountability. Reliability, measured using mDISCERN, ranged from 42.9±3.16 (ChatGPT-3.5) to 46.95±3.53 (Copilot). The most frequent question was "What is Keratoconus?" with 70% of websites providing relevant information. This received the highest mDISCERN score (49.33±4.96) and a relatively high GQS score (3.50±0.55), with an Automated Readability Level Calculator score of 13.17±2.13. Moderate positive correlations were determined between the website numbers and both mDISCERN (?=0.265,?=0.25) and GQS (?=0.453,?=0.05) scores. The quality of information, assessed using the GQS, ranged from 3.01±0.51 (ChatGPT-3.5) to 3.3±0.65 (Gemini) (p=0.34). The differences between the texts were statistically significant. Gemini emerged as the easiest to read, while ChatGPT-3.5 and Perplexity were the most difficult. Based on mDISCERN scores, Gemini and Copilot exhibited the highest percentage of responses in the "Good" range (51-62 points). For the GQS, the Gemini model exhibited the highest percentage of responses in the "Good" quality range, with 40% of its responses scoring 4-5. Conclusions: While all chatbots performed well, Gemini and Copilot showed better reliability and quality. However, their readability often exceeded recommended levels. Continuous improvements are essential to match information with patients' health literacy for effective use in ophthalmology.

28 March 2026 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
MBMübeccel BULUT
Mübeccel BULUT
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
To examine the potential of GPT-4V(ision) in evaluating age-related macular degeneration (AMD) and other ophthalmological pathologies through optical coher

8 September 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
ÇMÇağrı Mutaf
Çağrı Mutaf
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
MBMübeccel BULUT
Mübeccel BULUT
FYFunda Yüksekyayla
Funda Yüksekyayla
Background: This prospective observational study was conducted to systematically assess immediate changes occurring (within one hour) in corneal endothelial cell morphology and anterior segment parameters following Nd:YAG laser posterior capsulotomy in pseudophakic patients and to analyze the correlation between these changes and laser energy parameters. Methods: A single-arm, within-subject pre–post design was employed to evaluate corneal endothelial morphology (cell density, count, area, coefficient of variation and hexagonal percentage) and anterior chamber parameters (depth, angle, volume) before and one hour after the procedure using specular microscopy and Pentacam analysis. Patient demographics (age), clinical parameters (best corrected visual acuity and intraocular pressure), postoperative-YAG laser interval, and laser energy parameters (energy per shot, pulse count, and total applied energy) were also documented. Results: Thirty-two pseudophakic patients (mean age 56.3 ± 19.2 years) underwent Nd:YAG laser posterior capsulotomy with mean energy per shot of 3.15 ± 1.07 mJ and pulse count of 34.3 ± 20.4. Specular microscopy revealed significant post-procedural decreases in endothelial cell density (2184.05 to 2057.2 cells/mm2; p = 0.006) and increases in average cell area (529.25 ± 242.72 to 587.75 ± 281.09 µm2; p = 0.004) and minimum cell area (199.3 ± 170.62 to 248.35 ± 202.7 µm2; p = 0.035). Corneal topography also decreased significantly in the anterior chamber angle (40.07 ± 10.34 to 35.42 ± 6.78 degrees; p = 0.048), with positive correlations between energy per shot and endothelial cell density (r = 0.557; p = 0.011) and average cell area (r = 0.544; p = 0.013). Conclusions: This study demonstrates that Nd:YAG laser capsulotomy causes immediate, energy-dependent alterations in corneal endothelial density and anterior chamber parameters within one hour post-procedurally. The identification of energy per shot as a key determinant represents a preliminary observation for optimizing laser parameters and reducing potential complications in pseudophakic patients.

8 August 2025 in Medicine
Verified
Journal Article
Open access
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
ASALİ SİMSEK
ALİ SİMSEK
MBMübeccel BULUT
Mübeccel BULUT
FYFunda Yüksekyayla
Funda Yüksekyayla
İUİrfan Uzun
İrfan Uzun
TYTuba Yosun
Tuba Yosun
This study evaluates and compares choroidal vascular changes in patients undergoing phacoemulsification and scleral-fixated intraocular lens implantation. The research focused on assessing the choroidal vascular index (CVI) and choroidal thickness as indicators of vascular and structural integrity, using normal eyes as controls. This comparative study involved 135 eyes divided into 3 groups, phacoemulsification, scleral-fixated intraocular lens implantation, and control. Choroidal thickness and CVI were evaluated using optical coherence tomography within the first 3 months after surgery. Image binarization with ImageJ was used to calculate the luminal area, total choroidal area, and vascular index. No significant differences were determined in foveal choroidal thickness (P = .208; 274.48 ± 50.37 μm, 265.13 ± 41.68 μm, and 284.18 ± 58.69 μm for control, phacoemulsification, and scleral fixation groups, respectively) or temporal choroidal thickness (P = .243; 272.87 ± 51.37 μm, 267.71 ± 40.38 μm, and 284.60 ± 53.04 μm, respectively). However, nasal choroidal thicknesses differed between the groups (P < .05; 275.00 ± 45.13 μm, 261.53 ± 33.95 μm, and 285.14 ± 60.16 μm), with a significant difference between the phacoemulsification and scleral fixation groups (P = .024). Vascular parameters, including luminal area (P = .081), total subfoveal choroidal area (P = .070), and the CVI (P = .173), exhibited no statistically significant differences. While overall choroidal integrity remains preserved post-surgery, regional changes, particularly in the nasal choroid, suggest a localized hemodynamic response affected by surgical manipulation and inflammation. These findings highlight the importance of monitoring choroidal changes to improve postoperative management.