İrfan Uzun

Dr. İrfan Uzun

Department of Ophthalmology, Harran University, Sanliurfa, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
ÇMÇağrı Mutaf
Çağrı Mutaf
İUİrfan Uzun
İrfan Uzun
FYFunda Yüksekyayla
Funda Yüksekyayla
Background: This study evaluates the ability of six popular chatbots; ChatGPT-3.5, ChatGPT-4.0, Gemini, Copilot, Chatsonic, and Perplexity, to provide reliable answers to questions concerning keratoconus. Methods: Chatbots responses were assessed using mDISCERN (range: 15–75) and Global Quality Score (GQS) (range: 1–5) metrics. Readability was evaluated using nine validated readability assessments. We also addressed the quality and accountability of websites from which the questions originated. Results: We analyzed 20 websites, 65% “Private practice or independent user” and 35% “Official patient education materials”. The mean JAMA benchmark score was 1.40 ± 0.91 (0–4 points), indicating low accountability. Reliability, measured using mDISCERN, ranged from 42.91 ± 3.15 (ChatGPT-3.5) to 46.95 ± 3.53 (Copilot). The most frequent question was “What is keratoconus?” with 70% of websites providing relevant information. This received the highest mDISCERN score (49.30 ± 4.91) and a relatively high GQS score (3.40 ± 0.56) with an Automated Readability Level Calculator score of 13.17 ± 2.13. Moderate positive correlations were determined between the website numbers and both mDISCERN (r = 0.265, p = 0.25) and GQS (r = 0.453, p = 0.05) scores. The quality of information, assessed using the GQS, ranged from 3.02 ± 0.55 (ChatGPT-3.5) to 3.31 ± 0.64 (Gemini) (p = 0.34). The differences between the texts were statistically significant. Gemini emerged as the easiest to read, while ChatGPT-3.5 and Perplexity were the most difficult. Based on mDISCERN scores, Gemini and Copilot exhibited the highest percentage of responses in the “good” range (51–62 points). For the GQS, the Gemini model exhibited the highest percentage of responses in the “good” quality range with 40% of its responses scoring 4–5. Conclusions: While all chatbots performed well, Gemini and Copilot showed better reliability and quality. However, their readability often exceeded recommended levels. Continuous improvements are essential to match information with patients’ health literacy for effective use in ophthalmology.

19 May 2025 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
İUİrfan Uzun
İrfan Uzun
ÇMÇağrı Mutaf
Çağrı Mutaf
ARAli Hakim Reyhan
Ali Hakim Reyhan
FYFunda Yüksekyayla
Funda Yüksekyayla
ECEnes Colak
Enes Colak
MYMehmet Yolaçan
Mehmet Yolaçan
This study aims to comprehensively evaluate the trimester-specific effects of pregnancy on intraocular pressure, corneal biomechanics, anterior segment anatomy, and endothelial cell morphology. This prospective cross-sectional study included 90 healthy pregnant women (30 per trimester) and 30 age-matched non-pregnant controls. Comprehensive ophthalmological assessments were performed, including IOP measurement using a non-contact tonometer, corneal structure evaluation with Pentacam Scheimpflug imaging, and endothelial cell analysis using a specular microscope. A significant decrease in IOP was observed in the third trimester compared to the control group (p = 0.016), although no significant difference was noted in the first and second trimesters (p > 0.05). Corneal endothelial analysis revealed a significant decrease in hexagonal cell percentage (HEX) values during the first trimester (p = 0.007). Correlation analysis demonstrated a strong positive relationship between central corneal thickness (CCT) and corneal volume (r = 0.817, p < 0.001) and a moderate positive correlation between CCT and IOP (r = 0.263, p = 0.004). Axial length was strongly negatively correlated with both flat keratometry (r=-0.562, p < 0.001) and steep keratometry (r=-0.538, p < 0.001), and strongly positively correlated with anterior chamber volume and anterior chamber depth (r = 0.380, p < 0.001 and r = 0.384, p < 0.001, respectively). A moderate positive correlation was also identified between gestational trimester and HEX (r = 0.257, p = 0.005). Pregnancy induces temporary but significant ophthalmological changes, particularly a decrease in IOP in the third trimester and a decrease in HEX in the first. These findings highlight the importance of monitoring ocular health during pregnancy to detect potential risks early and ensure timely intervention.

5 September 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
ÇMÇağrı Mutaf
Çağrı Mutaf
İUİrfan Uzun
İrfan Uzun
FYFunda Yüksekyayla
Funda Yüksekyayla
This study evaluates the ability of six popular chatbots; ChatGPT-3.5, ChatGPT-4.0, Gemini, Copilot, Chatsonic, and Perplexity to provide reliable answers to questions concerning keratoconus. Methods: Chatbots responses were assessed using mDISCERN and Global Quality Score (GQS) metrics. Readability was evaluated using nine validated readability assessments. We also addressed the quality and accountability of websites from which the questions originated. Results: We analyzed 20 websites, 65% "Private practice or independent user" and 35% "Official patient education materials." The mean JAMA Benchmark score was 1.5±0.68, indicating low accountability. Reliability, measured using mDISCERN, ranged from 42.9±3.16 (ChatGPT-3.5) to 46.95±3.53 (Copilot). The most frequent question was "What is Keratoconus?" with 70% of websites providing relevant information. This received the highest mDISCERN score (49.33±4.96) and a relatively high GQS score (3.50±0.55), with an Automated Readability Level Calculator score of 13.17±2.13. Moderate positive correlations were determined between the website numbers and both mDISCERN (?=0.265,?=0.25) and GQS (?=0.453,?=0.05) scores. The quality of information, assessed using the GQS, ranged from 3.01±0.51 (ChatGPT-3.5) to 3.3±0.65 (Gemini) (p=0.34). The differences between the texts were statistically significant. Gemini emerged as the easiest to read, while ChatGPT-3.5 and Perplexity were the most difficult. Based on mDISCERN scores, Gemini and Copilot exhibited the highest percentage of responses in the "Good" range (51-62 points). For the GQS, the Gemini model exhibited the highest percentage of responses in the "Good" quality range, with 40% of its responses scoring 4-5. Conclusions: While all chatbots performed well, Gemini and Copilot showed better reliability and quality. However, their readability often exceeded recommended levels. Continuous improvements are essential to match information with patients' health literacy for effective use in ophthalmology.

8 August 2025 in Medicine
Verified
Journal Article
Open access
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
ASALİ SİMSEK
ALİ SİMSEK
MBMübeccel BULUT
Mübeccel BULUT
FYFunda Yüksekyayla
Funda Yüksekyayla
İUİrfan Uzun
İrfan Uzun
TYTuba Yosun
Tuba Yosun
This study evaluates and compares choroidal vascular changes in patients undergoing phacoemulsification and scleral-fixated intraocular lens implantation. The research focused on assessing the choroidal vascular index (CVI) and choroidal thickness as indicators of vascular and structural integrity, using normal eyes as controls. This comparative study involved 135 eyes divided into 3 groups, phacoemulsification, scleral-fixated intraocular lens implantation, and control. Choroidal thickness and CVI were evaluated using optical coherence tomography within the first 3 months after surgery. Image binarization with ImageJ was used to calculate the luminal area, total choroidal area, and vascular index. No significant differences were determined in foveal choroidal thickness (P = .208; 274.48 ± 50.37 μm, 265.13 ± 41.68 μm, and 284.18 ± 58.69 μm for control, phacoemulsification, and scleral fixation groups, respectively) or temporal choroidal thickness (P = .243; 272.87 ± 51.37 μm, 267.71 ± 40.38 μm, and 284.60 ± 53.04 μm, respectively). However, nasal choroidal thicknesses differed between the groups (P < .05; 275.00 ± 45.13 μm, 261.53 ± 33.95 μm, and 285.14 ± 60.16 μm), with a significant difference between the phacoemulsification and scleral fixation groups (P = .024). Vascular parameters, including luminal area (P = .081), total subfoveal choroidal area (P = .070), and the CVI (P = .173), exhibited no statistically significant differences. While overall choroidal integrity remains preserved post-surgery, regional changes, particularly in the nasal choroid, suggest a localized hemodynamic response affected by surgical manipulation and inflammation. These findings highlight the importance of monitoring choroidal changes to improve postoperative management.

26 March 2025 in Children
Verified
Journal Article
Open access
PDF file
İUİrfan Uzun
İrfan Uzun
ECEnes Colak
Enes Colak
ZAZeliha Atlıhan
Zeliha Atlıhan
ÇMÇağrı Mutaf
Çağrı Mutaf
ARAli Hakim Reyhan
Ali Hakim Reyhan
FYFunda YÜKSEKYAYLA
Funda YÜKSEKYAYLA
Background/Objectives: Childhood obesity is a significant health concern also capable of impacting ocular health. This study evaluates the effects of childhood obesity on corneal morphology, anterior chamber parameters, intraocular pressure (IOP), and corneal endothelial cell morphology. Understanding these relationships may contribute to early diagnosis and management strategies. Methods: This prospective, cross-sectional study was conducted at the Harran University Faculty of Medicine between January and December, 2024. Ninety children aged 7–17 years were included, with only the right eyes being analyzed. The participants were categorized into three groups based on body mass index (BMI) percentiles: normal weight (≤85th percentile), overweight (86–94th percentiles), and obese (≥95th percentile). All participants underwent comprehensive ophthalmological examinations, including IOP measurement with a non-contact tonometer, corneal topography assessment using a Scheimpflug camera, and endothelial cell morphology evaluation via specular microscopy. Results: IOP was significantly higher in the overweight and obese groups (p < 0.001). Central corneal thickness (CCT) also increased significantly in these groups (p < 0.05). Positive correlations were determined between BMI and IOP (r = 0.493, p < 0.001) and CCT (r = 0.345, p < 0.001). Additionally, waist circumference exhibited a strong correlation with BMI (r = 0.905, p < 0.001) and a significant association with IOP (r = 0.463, p < 0.001). No significant differences were observed among the groups in terms of other anterior chamber or endothelial parameters. Conclusions: Childhood obesity is associated with increased IOP and CCT, suggesting potential alterations in corneal biomechanics and ocular physiology. These findings highlight the importance of routine ophthalmological evaluation in obese children to detect early ocular changes and prevent long-term complications.

1 January 2025 in Journal of Clinical and Analytical Medicine
Verified
Journal Article
Closed access
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
FYFunda Yüksekyayla
Funda Yüksekyayla
MTmüslüm toptan
müslüm toptan
İUİrfan Uzun
İrfan Uzun
ÇMÇağrı Mutaf
Çağrı Mutaf
BTBüşra Türk
Büşra Türk