Funda Yüksekyayla

Dr. Funda Yüksekyayla

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
ÇMÇağrı Mutaf
Çağrı Mutaf
İUİrfan Uzun
İrfan Uzun
FYFunda Yüksekyayla
Funda Yüksekyayla
Background: This study evaluates the ability of six popular chatbots; ChatGPT-3.5, ChatGPT-4.0, Gemini, Copilot, Chatsonic, and Perplexity, to provide reliable answers to questions concerning keratoconus. Methods: Chatbots responses were assessed using mDISCERN (range: 15–75) and Global Quality Score (GQS) (range: 1–5) metrics. Readability was evaluated using nine validated readability assessments. We also addressed the quality and accountability of websites from which the questions originated. Results: We analyzed 20 websites, 65% “Private practice or independent user” and 35% “Official patient education materials”. The mean JAMA benchmark score was 1.40 ± 0.91 (0–4 points), indicating low accountability. Reliability, measured using mDISCERN, ranged from 42.91 ± 3.15 (ChatGPT-3.5) to 46.95 ± 3.53 (Copilot). The most frequent question was “What is keratoconus?” with 70% of websites providing relevant information. This received the highest mDISCERN score (49.30 ± 4.91) and a relatively high GQS score (3.40 ± 0.56) with an Automated Readability Level Calculator score of 13.17 ± 2.13. Moderate positive correlations were determined between the website numbers and both mDISCERN (r = 0.265, p = 0.25) and GQS (r = 0.453, p = 0.05) scores. The quality of information, assessed using the GQS, ranged from 3.02 ± 0.55 (ChatGPT-3.5) to 3.31 ± 0.64 (Gemini) (p = 0.34). The differences between the texts were statistically significant. Gemini emerged as the easiest to read, while ChatGPT-3.5 and Perplexity were the most difficult. Based on mDISCERN scores, Gemini and Copilot exhibited the highest percentage of responses in the “good” range (51–62 points). For the GQS, the Gemini model exhibited the highest percentage of responses in the “good” quality range with 40% of its responses scoring 4–5. Conclusions: While all chatbots performed well, Gemini and Copilot showed better reliability and quality. However, their readability often exceeded recommended levels. Continuous improvements are essential to match information with patients’ health literacy for effective use in ophthalmology.

5 September 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
ÇMÇağrı Mutaf
Çağrı Mutaf
İUİrfan Uzun
İrfan Uzun
FYFunda Yüksekyayla
Funda Yüksekyayla
This study evaluates the ability of six popular chatbots; ChatGPT-3.5, ChatGPT-4.0, Gemini, Copilot, Chatsonic, and Perplexity to provide reliable answers to questions concerning keratoconus. Methods: Chatbots responses were assessed using mDISCERN and Global Quality Score (GQS) metrics. Readability was evaluated using nine validated readability assessments. We also addressed the quality and accountability of websites from which the questions originated. Results: We analyzed 20 websites, 65% "Private practice or independent user" and 35% "Official patient education materials." The mean JAMA Benchmark score was 1.5±0.68, indicating low accountability. Reliability, measured using mDISCERN, ranged from 42.9±3.16 (ChatGPT-3.5) to 46.95±3.53 (Copilot). The most frequent question was "What is Keratoconus?" with 70% of websites providing relevant information. This received the highest mDISCERN score (49.33±4.96) and a relatively high GQS score (3.50±0.55), with an Automated Readability Level Calculator score of 13.17±2.13. Moderate positive correlations were determined between the website numbers and both mDISCERN (?=0.265,?=0.25) and GQS (?=0.453,?=0.05) scores. The quality of information, assessed using the GQS, ranged from 3.01±0.51 (ChatGPT-3.5) to 3.3±0.65 (Gemini) (p=0.34). The differences between the texts were statistically significant. Gemini emerged as the easiest to read, while ChatGPT-3.5 and Perplexity were the most difficult. Based on mDISCERN scores, Gemini and Copilot exhibited the highest percentage of responses in the "Good" range (51-62 points). For the GQS, the Gemini model exhibited the highest percentage of responses in the "Good" quality range, with 40% of its responses scoring 4-5. Conclusions: While all chatbots performed well, Gemini and Copilot showed better reliability and quality. However, their readability often exceeded recommended levels. Continuous improvements are essential to match information with patients' health literacy for effective use in ophthalmology.

8 September 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
ÇMÇağrı Mutaf
Çağrı Mutaf
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
MBMübeccel BULUT
Mübeccel BULUT
FYFunda Yüksekyayla
Funda Yüksekyayla
Background: This prospective observational study was conducted to systematically assess immediate changes occurring (within one hour) in corneal endothelial cell morphology and anterior segment parameters following Nd:YAG laser posterior capsulotomy in pseudophakic patients and to analyze the correlation between these changes and laser energy parameters. Methods: A single-arm, within-subject pre–post design was employed to evaluate corneal endothelial morphology (cell density, count, area, coefficient of variation and hexagonal percentage) and anterior chamber parameters (depth, angle, volume) before and one hour after the procedure using specular microscopy and Pentacam analysis. Patient demographics (age), clinical parameters (best corrected visual acuity and intraocular pressure), postoperative-YAG laser interval, and laser energy parameters (energy per shot, pulse count, and total applied energy) were also documented. Results: Thirty-two pseudophakic patients (mean age 56.3 ± 19.2 years) underwent Nd:YAG laser posterior capsulotomy with mean energy per shot of 3.15 ± 1.07 mJ and pulse count of 34.3 ± 20.4. Specular microscopy revealed significant post-procedural decreases in endothelial cell density (2184.05 to 2057.2 cells/mm2; p = 0.006) and increases in average cell area (529.25 ± 242.72 to 587.75 ± 281.09 µm2; p = 0.004) and minimum cell area (199.3 ± 170.62 to 248.35 ± 202.7 µm2; p = 0.035). Corneal topography also decreased significantly in the anterior chamber angle (40.07 ± 10.34 to 35.42 ± 6.78 degrees; p = 0.048), with positive correlations between energy per shot and endothelial cell density (r = 0.557; p = 0.011) and average cell area (r = 0.544; p = 0.013). Conclusions: This study demonstrates that Nd:YAG laser capsulotomy causes immediate, energy-dependent alterations in corneal endothelial density and anterior chamber parameters within one hour post-procedurally. The identification of energy per shot as a key determinant represents a preliminary observation for optimizing laser parameters and reducing potential complications in pseudophakic patients.

8 August 2025 in Medicine
Verified
Journal Article
Open access
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
ASALİ SİMSEK
ALİ SİMSEK
MBMübeccel BULUT
Mübeccel BULUT
FYFunda Yüksekyayla
Funda Yüksekyayla
İUİrfan Uzun
İrfan Uzun
TYTuba Yosun
Tuba Yosun
This study evaluates and compares choroidal vascular changes in patients undergoing phacoemulsification and scleral-fixated intraocular lens implantation. The research focused on assessing the choroidal vascular index (CVI) and choroidal thickness as indicators of vascular and structural integrity, using normal eyes as controls. This comparative study involved 135 eyes divided into 3 groups, phacoemulsification, scleral-fixated intraocular lens implantation, and control. Choroidal thickness and CVI were evaluated using optical coherence tomography within the first 3 months after surgery. Image binarization with ImageJ was used to calculate the luminal area, total choroidal area, and vascular index. No significant differences were determined in foveal choroidal thickness (P = .208; 274.48 ± 50.37 μm, 265.13 ± 41.68 μm, and 284.18 ± 58.69 μm for control, phacoemulsification, and scleral fixation groups, respectively) or temporal choroidal thickness (P = .243; 272.87 ± 51.37 μm, 267.71 ± 40.38 μm, and 284.60 ± 53.04 μm, respectively). However, nasal choroidal thicknesses differed between the groups (P < .05; 275.00 ± 45.13 μm, 261.53 ± 33.95 μm, and 285.14 ± 60.16 μm), with a significant difference between the phacoemulsification and scleral fixation groups (P = .024). Vascular parameters, including luminal area (P = .081), total subfoveal choroidal area (P = .070), and the CVI (P = .173), exhibited no statistically significant differences. While overall choroidal integrity remains preserved post-surgery, regional changes, particularly in the nasal choroid, suggest a localized hemodynamic response affected by surgical manipulation and inflammation. These findings highlight the importance of monitoring choroidal changes to improve postoperative management.

13 June 2025 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Open access
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
FYFunda Yüksekyayla
Funda Yüksekyayla
İUİrfan Uzun
İrfan Uzun
ÇMÇağrı Mutaf
Çağrı Mutaf
MBMübeccel BULUT
Mübeccel BULUT
MEMehmet Eryavuz
Mehmet Eryavuz
This study evaluated the clinical outcomes of cases of nucleus drop developing during phacoemulsification surgery. It particularly focused on analyzing the effects of pars plana vitrectomy (PPV) on postoperative visual and anatomical parameters, including choroidal thickness and the choroidal vascular index (CVI). Patients who experienced nucleus drop during phacoemulsification and subsequently underwent PPV were reviewed retrospectively. Data for these cases were compared with a group of patients who underwent uncomplicated phacoemulsification and with a healthy control group. Key parameters assessed included surgical outcomes and changes in choroidal metrics, including quantitative assessments of choroidal thickness in various regions and the CVI, measured using enhanced depth imaging optical coherence tomography. Mean visual acuity in the PPV eyes was 0.44±0.11, significantly lower than the 0.71±0.13 in the phacoemulsification group and 0.80±0.08 in the controls (p < 0.001). Nasal choroidal thickness at 1000 µm was markedly lower in the PPV eyes (282.08±53.67 µm) compared with both the phacoemulsification (341.94±54.88 µm) and control (379.19±67.65 µm; p < 0.001) groups, with similar significant decreases being observed across other choroidal thickness parameters. However, no significant intergroup differences were observed in terms of CVI or stromal area/luminal area (LA/SA) ratio values (p > 0.05). The study findings demonstrated that decreases observed in choroidal thickness, total choroidal area, luminal area, and stromal area measurements indicate that this procedure affects the anatomical structure. However, the similarities in CVI and LA/SA ratio values suggest that the relative balance within the microvascular structure is maintained.

1 January 2025 in Journal of Clinical and Analytical Medicine
Verified
Journal Article
Closed access
ARALİ HAKİM REYHAN
ALİ HAKİM REYHAN
FYFunda Yüksekyayla
Funda Yüksekyayla
MTmüslüm toptan
müslüm toptan
İUİrfan Uzun
İrfan Uzun
ÇMÇağrı Mutaf
Çağrı Mutaf
BTBüşra Türk
Büşra Türk