Yuepeng Xin

Mr. Yuepeng Xin


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2024 in Electronics
Verified
Journal Article
Open access
PDF file
MWMinxin Wang
Minxin Wang
YLYong Liu
Yong Liu
YHYoucong Huang
Youcong Huang
YXYuepeng Xin
Yuepeng Xin
THTao Han
Tao Han
BDBoxue Du
Boxue Du
This paper proposes an online monitoring and defect identification method for XLPE power cables using harmonic visualization of grounding currents. Four typical defects, including thermal aging, water ingress and dampness, insulation scratch, and excessive bending, were experimentally conducted. The AC grounding currents of the cable specimens with different defects were measured during operation. By using the chaotic synchronization system, the harmonic distortion was transformed into a 2D scatter diagram with distinctive characteristics. The relationship between the defect type and the diagram features was obtained. A YOLOv5 (you only look once v5) target recognition model was then established based on the dynamic harmonics scatter diagrams for cable defect classification and identification. The results indicated that the overall shape, distribution range, density degree, and typical lines formed by scatter aggregation can reflect the defect type effectively. The proposed method greatly reduces the difficulty of data analysis and enables rapid defect identification of XLPE power cables, which is useful for improving the reliability of the power system.

15 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YLYong Liu
Yong Liu
YXYuepeng Xin
Yuepeng Xin
YHYoucong Huang
Youcong Huang
BDBoxue Du
Boxue Du
XHXingwang Huang
Xingwang Huang
JSJingang Su
Jingang Su
The state detection of power cables is very important to ensure the reliability of the power supply. Traditional sensors are mostly based on electric field detection. The operation is complex, and its efficiency needs to be improved. This paper optimizes the design and development of the magnetic field detection sensor for AC power cables. First, through the establishment of the magnetic field sensor model, it is determined that permalloy is the material of the magnetic core, the optimal aspect ratio of the magnetic core is 20, and the ratio of coil length to core length is 0.3. Second, the coil-simulation model is established, and it is determined that the optimal number of turns of the coil is 11,000 turns, the diameter of the enameled copper wire is 0.08 mm, and the equivalent magnetic field noise of the sensor is 0.06 pT. Finally, the amplifying circuit based on negative magnetic flux feedback is designed, the sensor is assembled, and the experimental circuit is built for the sensitivity test. The results show that the sensitivity of the magnetic field sensor is 327.6 mV/μT. The sensor designed in this paper has the advantages of small size, high sensitivity, ease of carry, and high reliability.

22 March 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
YLYong Liu
Yong Liu
YXYuepeng Xin
Yuepeng Xin
BDBoxue Du
Boxue Du
XHXingwang Huang
Xingwang Huang
JSJingang Su
Jingang Su
The state detection of power cable is very important to ensure the reliability of power supply. Traditional sensors are mostly based on electric field detection, the operation is complex, and its efficiency needs to be improved. This paper optimizes the design and development of the magnetic field detection sensor for AC power cables. Firstly, through the establishment of the magnetic field sensor model, it is determined that permalloy is the material of the magnetic core, the optimal aspect ratio of the magnetic core is 20, and the ratio of coil length to core length is 0.3. Secondly, the coil simulation model is established, and it is determined that the optimal number of turns of the coil is 11000 turns, the diameter of the enamelled copper wire is 0.08mm, and the equivalent magnetic field noise of the sensor is 0.06pT. Finally, the amplifying circuit based on negative magnetic flux feedback is designed and the sensor is assembled, and the experimental circuit is built for sensitivity test. the results show that the sensitivity of the magnetic field sensor is 327.6mV/μT. The sensor designed in this paper has the advantages of small size, high sensitivity, easy to carry and high reliability.