Space charges tend to accumulate on the surface and at the interface of ethylene–propylene–diene terpolymer (EPDM), serving as high voltage direct current (HVDC) cable accessory insulation, which likely induces electrical field distortion and dielectric breakdown. Direct fluorination is an effective method to modify the surface characteristics of the EPDM without altering the bulk properties too much. In this paper, the surface morphology, hydrophobic properties, relative permittivity, and DC conductivity of the EPDM before and after fluorination treatment were tested. Furthermore, the surface and interface charge behaviors in the HVDC cable accessory were investigated by the pulsed electroacoustic (PEA) method, and explained from the point of view of trap distribution. The results show that fluorination helps the EPDM polymer obtain lower surface energy and relative permittivity, which is beneficial to the interface match in composite insulation systems. The lowest degree of space charge accumulation occurs in EPDM with 30 min of fluorination. After analyzing the results of the 3D potentials and the density of states (DOS) behaviors in EPDM before and after fluorination, it can be found that fluorination treatment introduces shallower electron traps, and the special electrostatic potential after fluorination can significantly suppress the space charge accumulation at the interface in the HVDC cable accessory.
Thermal aging is a common form of cable deterioration. In this paper, the effect of thermal aging on cables is evaluated by analyzing the harmonic characteristics in cable leakage currents. Cable samples were first fabricated and subjected to accelerated thermal aging tests at 120 °C. The experimental circuits were built to test the dielectric loss factor and the AC leakage current of the cable at different aging times. Then, the improved variational modal decomposition (VMD) algorithm was used for the time–frequency analysis of the leakage current, and the relationship between thermal aging and leakage current harmonics was investigated. Thermal aging was discovered to increase the capacitance and dielectric loss factor of the cable as well as generate harmonics in the leakage current, with harmonics at 150, 450, and 650 Hz being particularly sensitive to thermal aging. The multidimensional characteristic parameters such as the time-domain, frequency-domain, and relative energy and the sample entropy of the leakage current harmonics were calculated. The results demonstrated thermal aging increased the relative energy and power spectrum energy of the harmonics and increased the disorder of the harmonic sequence.
9 January 2017 in IEEE Transactions on Power Delivery
Self-normalizing multivariate (SNM) analysis method was proposed to reflect characteristics of leakage current for monitoring dynamic surface discharges to flashover on polymer insulator in severe fog-polluted conditions. Based on the observation of discharge phenomena and temporal measurement of leakage current, the process just prior to flashover was separated into four stages: dominated resistive current, partial discharge, stable dry-band discharge, and pre-flashover. With discharge propagation in these stages, the SNM map was obtained. With increasing the pollution level, the SNM map shows no obvious difference in the resistive current dominated stage, while it looses more symmetry in both stable dry-band discharge and pre-flashover stages, which indicates the highest probability of surface flashover occurrence under the most severe fog condition investigated.
Wettability has become one of the most important factors influencing power equipment insulation system in coastal power grid, which can seriously threaten the safety of power grid. This paper aimed at numerical simulation and experimental investigation on dynamic formation mechanism of water droplet and induced surface discharges on silicone rubber composites under different AC voltages, considering the factors of surface tension and droplet volume. Obtained results reveal that the spreading coefficient increases with increasing the electric field intensity from 1 to 5 kV/cm and with increasing the droplet volume from 10 to 50 µL. The spreading coefficient shows a decreasing tendency when the surface tension increases from 29.3 to 61.0 mN/m. Moreover, the maximum of surface electric field shows an increasing tendency under the condition of increasing both the droplet volume and the surface tension. On the basis of the physical model of droplet deformation, the electric field force and the surface tension play a significant role in the process of droplet deformation. Meanwhile, the experimental results are consistent with the simulation analysis, reflecting that the droplet deformation and the induced surface discharges mainly depend on two parameters: the droplet volume and the magnitude of applied voltage.
This paper proposes an online monitoring and defect identification method for XLPE power cables using harmonic visualization of grounding currents. Four typical defects, including thermal aging, water ingress and dampness, insulation scratch, and excessive bending, were experimentally conducted. The AC grounding currents of the cable specimens with different defects were measured during operation. By using the chaotic synchronization system, the harmonic distortion was transformed into a 2D scatter diagram with distinctive characteristics. The relationship between the defect type and the diagram features was obtained. A YOLOv5 (you only look once v5) target recognition model was then established based on the dynamic harmonics scatter diagrams for cable defect classification and identification. The results indicated that the overall shape, distribution range, density degree, and typical lines formed by scatter aggregation can reflect the defect type effectively. The proposed method greatly reduces the difficulty of data analysis and enables rapid defect identification of XLPE power cables, which is useful for improving the reliability of the power system.
Serious ice accretion will cause structural problems and ice flashover accidents, which result in outdoor insulator string operating problems in winter conditions. Previous investigations have revealed that the thicker and longer insulators are covered with ice, the icing degree becomes worse and icing accident probability increases. Therefore, an image processing method was proposed to extract the characteristics of the icicle length and Rg (ratio of the air gap length to the insulator length) of ice-covered insulators for monitoring the operation of iced outdoor insulator strings. The tests were conducted at the artificial climate room of CIGELE Laboratories recommended by IEEE Standard 1783/2009. The surface phenomena of the insulator during the ice accretion process were recorded by using a high-speed video camera. In the view of the ice in the background of the picture of fuzzy features and high image noise, a direct equalization algorithm is used to enhance the grayscale iced image contrast. The median filtering method is conducted for reducing image noise and sharpening the image edge. The maximum entropy threshold segmentation algorithm is put forward to extract the insulators and its surface ice from the background. Then, the modified Canny operator edge detection algorithm is selected to trace the boundaries of objects through the extraction of information about attributes of the endpoints of edges. After we obtained the improved Canny edge detection image for both of the ice-covered insulators and non-iced insulators, the icing thickness can be obtained by calculating the difference between the edge of the non-iced insulators image and the edge of the iced insulator image. Besides, in order to identify the icing degree of the insulators more accurately, this paper determines the location of icicles by using the region growth method. After that, the icicle length and Rg can be obtained to monitor the icing degree of the insulator. It will be helpful to improve the ability to judge the accident risk of insulators in power systems.