The aim of this study is evaluate the efficacy of TachoSil patches in controlling suture-hole bleeding after elective infrarenal abdominal aortic aneurysm (AAA) replacement with Dacron graft. Patients undergoing elective replacement of infrarenal AAA with Dacron grafts were prospectively randomized to TachoSil patches (Group I) or standard compression with surgical swabs (Group II).We evaluated time to haemostasis, blood loss during the operation, blood loss after cross-clamp removal, duration of operation, drain volume, requirement for blood transfusion and surgeons rating of efficacy. Twenty patients were randomized (10 patients in each treatment Group). The mean time to haemostasis was 264 +/- 127.1 s (range: 180-600 s) in Group I and 408 +/- 159.5 s (range: 120-720 s) in Group II (p = 0.026); mean blood loss during the operation was 503.5 +/- 20.7 cc (range: 474-545 cc) in Group I and 615.7 +/- 60.3 cc (range: 530-720 cc) in Group II (p < 0.001); mean blood loss after cross-clamp removal was 26.5 +/- 4 g (range: 22-34 g) in Group I and 45.4 +/- 4.6 (range: 38-52 g) in Group II (p < 0.001) and mean drain volume was 116.7 +/- 41.4 cc (range: 79-230 cc) in Group I and 134.5 +/- 42.8 cc (range: 101-250 cc) in Group II (p = 0.034). There were no serious adverse events associated with use of TachoSil patches. For patients undergoing aortic reconstruction with Dacron grafts, TachoSil patches were found to be safe and effective for the control of suture-hole bleeding.
Background: Hybrid treatments (HT) aim to reduce conventional open surgery invasiveness and address multilevel peripheral arterial disease (PAD). Herein, the simultaneous HT treatment in patients with chronic limb-threatening ischemia (CLTI) is reported. Methods: Retrospective analysis, for the period from May 2012 to April 2018, of patients presenting multilevel PAD with CLTI addressed with simultaneous HT. The outcomes of these interventions were measured the following metrics: early technical successes (within 30 days following treatment) and late technical successes (30 days or more following treatment) and included mortality, morbidity symptoms recurrence, and amputation. Survival and patencies were estimated. The median follow-up was 43.77 months. Results: In the 45 included patients, the HT consisted of femoral bifurcation patch angioplasty followed by an endovascular treatment in 38 patients (84.4%) and endovascular treatment followed by a surgical bypass in 7 patients (15.6%). Technical success was 100% without perioperative mortality. Eight (17.8%) patients presented early complications without major amputations. During the follow-up, seven (15.6%) deaths occurred and six patients (13.3%) experienced symptoms recurrence, with five of those patients requiring major amputation. An estimated survival time of 5 years, primary patency, and secondary patency was 84.4%, 79.2%, and 83.3% respectively. Conclusions: Hybrid treatments are effective in addressing patients presenting with multilevel PAD and CLTI. The common femoral artery involvement influences strategy selection. Larger studies with longer-term outcomes are required to validate the hybrid approach, indications, and results.
Background: Endovascular aortic repair (EVAR) is generally performed with bi/trimodular stent-grafts requiring retrograde contralateral gate cannulation (CGC). In the case of tricky CGC, an increased EVAR procedural time and radiation exposure have been reported. Herein, we compare the outcomes of conventional CGC and CGC using the speed gate cannulation (SGC) technique in standard EVAR for a propensity-matched cohort. Methods: A total of 371 patients were retrospectively analyzed. Inclusion criteria were fulfilled in 172 patients who underwent propensity score matching. Primary outcomes included operative time, CGC time, mean contrast medium, fluoroscopy time, and CGC fluoroscopy time. Results: After matching, 78 patients were included in each group (SGC vs. standard). Primary outcomes registered a significant reduction in CGC time (4 [1–6] vs. 8 [6–14] min; p = 0.001) and fluoroscopy time (12 [9–16] vs. 17 [12–25] min). Conclusions: In this preliminary experiment, the use of SGC was feasible with no significant registered postoperative complications. A significant reduction in contrast medium usage, radiation exposure, and CGC time was observed with the use of SGC. SGC is a simple adjunctive technique, and its use should be considered in standard EVAR, especially in emergency scenarios, where time is of the essence.
The intima-media thickness (IMT) and its irregularities or ulcerations in the common carotid artery (CCA) are useful tools as sentinel biomarkers for the integrity of the cardiovascular system. Total homocysteine and lipoprotein levels are the most commonly used elements in cardiovascular risk stratification. Duplex ultrasound (DUS), associated with serum biomarkers, can be used simply to assess the degree of atherosclerotic disease and cardiovascular risk. This study highlights the role of different kinds of biomarkers, showing their usefulness and potentiality in multi-district atherosclerotic patients, especially for early diagnosis and therapy effectiveness monitoring. A retrospective analysis performed from September 2021 to August 2022, of patients with carotid artery disease, was performed. A total of 341 patients with a mean age of 53.8 years were included in the study. The outcomes showed an increased risk of stroke in patients with significative carotid artery disease, nonresponsive to therapy, monitored through a series of serum biomarkers (homocysteine, C-reactive protein, and oxidized LDL). In this reported experience, the systematic use of DUS in association with the multiple biomarkers approach was effective for the early identification of patients at higher risk of disease progression or inefficient therapy.
In patients with end-stage renal failure requiring hemodialysis, autogenous arteriovenous fistula (AVF) is preferred over tunneled dialysis catheters due to lower complications and costs. However, AVF maturation failure remains a common issue due to small vein size, multiple venipunctures, and other factors. Guidelines recommend using vessels of >2 mm for forearm AVFs and >3 mm for upper arm AVFs. This study investigates the use of intraoperative Doppler ultrasound (DUS)-guided Balloon-Assisted Maturation (BAM) with drug-eluting balloons (DEB) during initial AVF creation. Data from 114 AVF procedures, of which 27.2% underwent BAM, were analyzed. BAM was performed in 25 distal radio-cephalic and 6 proximal brachio-cephalic AVFs. With DUS guidance, vein stenosis was identified and treated using DEB. Technical success was achieved in all cases, with no early mortality. Early BAM-related complications were minimal, and no AVF thrombosis occurred. AVF maturation time was 15 days (SD: 3), and no further complications were reported during a mean follow-up of 10.38 months. Using BAM with DEB during AVF creation led to successful maturation and dialysis use without the need for secondary procedures. This study emphasizes the importance of identifying AVF failure risk early and utilizing DUS-guided procedures to enhance AVF outcomes. A more liberal use of intraoperative BAM could limit reinterventions in patients undergoing AVFs.
Endovascular aneurysm repair (EVAR) has become the preferred approach over open repair for abdominal aortic aneurysms (AAAs) due to its minimally invasive nature. The common femoral artery (CFA) is the main access vessel for EVAR, with both surgical exposure and percutaneous access being utilized. However, in emergent cases, percutaneous access can be challenging and may result in complications such as bleeding or dissection thrombosis, leading to the need for surgical conversion. This study aimed to share experiences in implementing a decision-making algorithm to reduce surgical conversions due to percutaneous access failures. A total of 74 aortic patients treated with EVAR in emergency settings were included in this retrospective study. This study focused on various outcomes such as perioperative mortality, morbidity, procedure time, surgical exposure time, and surgical conversion rate. After the implementation of the decision-making algorithm, decreases in surgical conversions and operating time were observed. Percutaneous access was found to be more challenging in cases with specific anatomical characteristics of the CFA, such as severe atherosclerosis or smaller vessel diameter. This study highlighted the importance of carefully assessing patient anatomical features and utilizing a decision-making algorithm to optimize outcomes in EVAR procedures. Further research is needed to continue improving practices for managing aortic aneurysms and reducing complications in femoral artery access approaches.