Background: Endovascular aneurysm repair (EVAR) is the preferred treatment for abdominal aortic aneurysms (AAAs). This study evaluated the differences between the anticipated and actual achieved proximal sealing zones for standard EVAR endografts and their potential implications in a real-world AAA population. Methods: Data from 275 consecutive EVAR patients treated with the Endurant endograft (Medtronic, Minneapolis, MN, USA) between 2009 and 2022 were retrospectively analyzed. The proximal sealing zone was calculated preoperatively (target anticipated sealing zone, TASZ) and postoperatively (real achieved sealing zone, RASZ) from computed tomography angiography (CTA) images. These metrics were evaluated by assuming that they had a truncated cone shape, calculating the cone’s lateral surface by measuring the proximal and distal centerline areas and the distance between the planes. The primary outcome was the occurrence of type 1A endoleak at the longest available follow-up. Results: RASZ was significantly smaller and shorter than TASZ (p = 0.001), with an average area reduction of 24.5 mm2 and a median length reduction of 3 mm. Area and cranial length loss were present even when correcting for graft positioning imperfections. In the Cox proportional hazard regression model, TASZ and RASZ lengths were both independently associated with a lower risk of type 1A endoleak (HR: 0.88, 95% CI 0.80–0.96 and HR: 0.92, 95% CI 0.86–0.99, respectively). A Kaplan–Meier analysis confirmed that patients with RASZ > 5.5 mm had a survival free from endoleak higher than patients with RASZ ≤ 5.5 mm. Conclusions: In this real-world AAA population, the achieved proximal sealing zone was significantly shorter and smaller than planned, regardless of optimal endograft placement. The early calculation of RASZ, i.e., the PSZ achieved via CTA, is critical for risk stratification and follow-up.
Background: Carotid artery stenting (CAS) using first-generation single-layer stents is widely accepted as a good alternative to standard carotid endarterectomy (CEA) but it is associated with worse outcomes in terms of both plaque prolapse and cerebral embolization. Aim: To evaluate the perioperative and midterm outcomes of CAS using the new-generation RoadsaverTM dual-layer micromesh-covered carotid stent. Methods: Herein, we present the results of an observational, retrospective, multicentric study on non-consecutive patients who underwent the CAS procedure between January 2017 and December 2022 at three Italian, high-volume vascular surgery centers. The inclusion criteria were the patients’ eligibility for the CAS procedure in accordance with the current Italian guidelines, and the implantation of a Roadsaver stent. Both symptomatic and asymptomatic patients were included in the study. The patients requiring reintervention for carotid restenosis following CEA were also included. Perioperative data regarding procedural success was defined as the successful implantation of the device in the desired position, less than 30% residual stenosis, and the absence of intraoperative neurological complications. The primary outcome was any adverse cerebrovascular event such as stroke or transient ischemic attack (TIA) during the procedure and/or after discharge. The secondary outcomes were the need for further intervention, and all-cause death following procedure. Results: Three-hundred-fifty-three (353) patients were included in our study; the mean age was 74.3 years. A total of 5.9% of the patients were symptomatic on their operated side, while 7.3% had contralateral carotid occlusion. A cerebral embolic protection device (CPD) was employed in all patients. A total of 13.3% of the patients were operated on for restenosis after CEA Technical success was achieved in 96.9% of the cases with an intraoperative report of six TIAs (1.7%) and six ipsilateral strokes (1.7%). The mean hospital stay was 1.8 days. The thirty-day follow up showed one TIA and one more stroke. At the mean 35-month follow-up time, the primary outcome was present in six patients (1.7%), where four TIAs (1.1%) and two strokes (0.5%) were reported. Restenosis occurred in five patients (1.4%). Death for any cause was reported in 11 patients (3.1%). Conclusions: As most recent, high-quality studies show, the CAS procedure with second-generation devices such as the Roadsaver stent is safe and effective in preventing carotid-related cerebrovascular events in both symptomatic and asymptomatic patients. The intraoperative and postoperative cerebrovascular complication rate in high volume centers is very low, ensuring confidence in its employment for the CAS procedure along with a CPD as a valid alternative to CEA.
The intima-media thickness (IMT) and its irregularities or ulcerations in the common carotid artery (CCA) are useful tools as sentinel biomarkers for the integrity of the cardiovascular system. Total homocysteine and lipoprotein levels are the most commonly used elements in cardiovascular risk stratification. Duplex ultrasound (DUS), associated with serum biomarkers, can be used simply to assess the degree of atherosclerotic disease and cardiovascular risk. This study highlights the role of different kinds of biomarkers, showing their usefulness and potentiality in multi-district atherosclerotic patients, especially for early diagnosis and therapy effectiveness monitoring. A retrospective analysis performed from September 2021 to August 2022, of patients with carotid artery disease, was performed. A total of 341 patients with a mean age of 53.8 years were included in the study. The outcomes showed an increased risk of stroke in patients with significative carotid artery disease, nonresponsive to therapy, monitored through a series of serum biomarkers (homocysteine, C-reactive protein, and oxidized LDL). In this reported experience, the systematic use of DUS in association with the multiple biomarkers approach was effective for the early identification of patients at higher risk of disease progression or inefficient therapy.
Background. Vasoactive drugs are considered an important therapeutic tool in managing phlebolymphologic disease. The current study was performed to evaluate the results of a high-dose diosmin-based combination (Venoplant 2g) in symptomatic patients with chronic venous disease (CVD), treated with endovascular venous surgery, regarding the efficacy of this treatment and the clinical signs and patients’ compliance. Methods: We identified, between April 2022 and March 2023, 50 patients with symptomatic CVD who underwent endovenous ablation and additionally were administered high-dose micronized diosmin. Parameters analyzed in the pre- and post-operative period were the venous clinical severity score (VCSS), the calf circumference, and a VEINES-QOL/Sym questionnaire. Treatment efficacy was assessed in post-operative follow-ups at 1 month and 2 months. Results: Quality-of-life analysis showed a significant improvement between t1 and t2 in both tests administered (VEINES-QOL/Sym: 55.2 ± 2.9, 39.2 ± 12.3, p: 0.001) (VCSS: 6.6 ± 1, 5.1 ± 0.7, p: 0.001). At the secondary endpoint, the results maintained the same improvement trend. Calf circumference was significantly reduced between t1 and t3 (41.7 ± 5.1, 38.3 ± 3.4, p: 0.001). Conclusion: High-dose diosmin, combined with sweet clover 320 mg, Centella asiatica 40 mg, and Vitamin C 200 mg, in patients treated with endovenous ablation, can be significantly effective in terms of clinical results in treating superficial venous disease. A patient’s calf circumference was also found to have decreased considerably during follow-up. No adverse effects have been recorded to date.
Renal artery aneurysm (RAA) is a rare, often asymptomatic disease (0.1% incidence in general population) and can be incidentally diagnosed during an abdominal imaging workup. The traditional, gold standard of treatment is open surgery, carrying with it, however, a high risk of nephrectomy, mortality, and collateral morbidity. The endovascular approach is currently the most valid alternative to treating RAAs reducing, as it does, the risks associated with the surgical approach/open surgery. Herein we report on our experience with a case of wide-necked RAA treated with the Pipeline Vantage (Medtronic) flow diverter stent. Wide-neck aneurysms are defined as having neck diameters greater than 4 mm. Our choice of endovascular treatment was preferred over the surgical option notwithstanding the large size of the neck and the involvement of the branching vessels.
Background/Objectives: Physician-modified endografts (PMEGs) have emerged as a treatment option for complex aortic pathologies. Uncertainty remains regarding the modification techniques and the most suitable materials for customization of fenestrated endografts. The aim of this study was to evaluate CE-marked endovascular aortic repair (EVAR) devices and suitable materials for device modification in PMEGs for juxtarenal and pararenal aortic pathologies. Methods: This single-center observational study included patients treated with the physician-modified TREO (Terumo Aortic, Inchinnan, UK) device between April and December 2024. All patients had aortic ruptures or symptomatic aneurysms and unfavorable anatomy or severe comorbidities, making standard EVAR and open repair unsuitable. Procedural data were recorded and analyzed, including in-hospital outcomes. The “wire visibility” and “sheath–wire contrast” of endografts were assessed under fluoroscopy, and different resheathing techniques were compared. Results: Technical success was achieved in all five patients. The number of fenestrations per patient was 2.6 (range: 1–4). In one patient (1/5), type Ib and type IIIc endoleaks were observed postoperatively, requiring reintervention. No in-hospital mortality occurred. The ICU and hospital stay were 24 h (range: 18–40 h) and 8 days (range: 6–20 days), respectively. Moreover, the One SNARE wire was identified as the wire with the highest “wire visibility”, and Endurant II showed the best “sheath–wire contrast”. Resheathing with the dedicated crimping device was superior to the tape-assisted method. Conclusions: The TREO platform, in synergy with suitable additional materials, offers a viable solution for urgent aortic pathologies requiring PMEGs. Continued refinement of materials and procedural standardization could enhance the long-term outcome.