Crucial benefits provided by partially coherent light microscopy such as improved spatial resolution, optical sectioning and speckle-noise suppression are exploited here to achieve 3D quantitative imaging: reconstruction of the object refractive index (RI). We present a partially coherent optical diffraction tomography technique (PC-ODT) that can be easily implemented in commercially available bright-field microscopes. We show that the high numerical apertures of the objective and condenser lenses, together with optical refocusing, are main issues for achieving fast and successful 3D RI reconstruction of weak objects. In particular, the optical refocusing is performed by a high-speed focus tunable lens mounted in front of the digital camera enabling compatibility with commercial microscopes. The technique is experimentally demonstrated on different examples: diatom cells (biosilica shells), polystyrene micro-spheres and blood cells. The results confirm the straightforward 3D-RI reconstruction of the samples providing valuable quantitative information for their analysis. Thus, the PC-ODT can be considered as an efficient and affordable alternative to coherent ODT which requires specially designed holographic microscopes.
The refractive index (RI) is an important optical characteristic that is often exploited in label-free microscopy for analysis of biological objects. A technique for 3D RI reconstruction of living cells has to be fast enough to capture the cell dynamics and preferably needs to be compatible with standard wide-field microscopes. To solve this challenging problem, we present a technique that provides fast measurement and processing of data required for real-time 3D visualization of the object RI. Specifically, the 3D RI is reconstructed from the measurement of bright-field intensity images, axially scanned by a high-speed focus tunable lens mounted in front of a sCMOS camera, by using a direct deconvolution approach designed for partially coherent light microscopy in the non-paraxial regime. Both the measurement system and the partially coherent illumination, that provides optical sectioning and speckle-noise suppression, enable compatibility with wide-field microscopes resulting in a competitive and affordable alternative to the current holographic laser microscopes. Our experimental demonstrations show video-rate 3D RI visualization of living bacteria both freely swimming and optically manipulated by using freestyle laser traps allowing for their trapping and transport along 3D trajectories. These results prove that is possible to conduct simultaneous 4D label-free quantitative imaging and optical manipulation of living cells, which is promising for the study of the cell biophysics and biology.
Quantitative label-free imaging is an important tool for the study of living microorganisms that, during the last decade, has attracted wide attention from the optical community. Optical diffraction tomography (ODT) is probably the most relevant technique for quantitative label-free 3D imaging applied in wide-field microscopy in the visible range. The ODT is usually performed using spatially coherent light illumination and specially designed holographic microscopes. Nevertheless, the ODT is also compatible with partially coherent illumination and can be realized in conventional wide-field microscopes by applying refocusing techniques, as it has been recently demonstrated. Here, we compare these two ODT modalities, underlining their pros and cons and discussing the optical setups for their implementation. In particular, we pay special attention to a system that is compatible with a conventional wide-field microscope that can be used for both ODT modalities. It consists of two easily attachable modules: the first for sample illumination engineering based on digital light processing technology; the other for focus scanning by using an electrically driven tunable lens. This hardware allows for a programmable selection of the wavelength and the illumination design, and provides fast data acquisition as well. Its performance is experimentally demonstrated in the case of ODT with partially coherent illumination providing speckle-free 3D quantitative imaging.
Optical diffraction tomography based on partially coherent illumination (PC-ODT) is a quantitative label-free imaging technique that allows reconstructing of the object’s 3D refractive index from measured through-focus intensity images. PC illumination provides advantages such as speckle noise-free imaging and inherent compatibility with conventional wide-field microscopes. Here we experimentally demonstrate that a proper design of the PC illumination, different from the familiar bright-field one, and the use of more realistic optical transfer functions (OTFs) have crucial importance in PC-ODT to significantly increase the accuracy in 3D refractive index reconstruction. While realistic OTFs properly account for the real experimental illumination conditions, the proposed PC illumination design allows for gathering the object spatial-frequency content attenuated when bright-field illumination is used.
Optical diffraction tomography (ODT) is a computational imaging technique based on refractive index (RI) contrast. Its application for microscopic imaging of weakly absorbing and scattering samples has been demonstrated by using a specially designed holographic microscope with angular scanning of the coherent sample illumination direction. Recently, an alternative low cost technique based on partially coherent sample illumination (PC-ODT), which is compatible with the conventional wide-field transmission microscope, has been established. In this case, the 3D refractive index distribution of the sample is obtained by deconvolution from a single stack of through-focus intensity images. The performance of PC-ODT has been successfully tested on various fixed specimens (diatom frustule and biological cells) and moving bacteria. Here, we demonstrate that the PC-ODT is an efficient tool for the analysis of living eukaryotic cell dynamics at short- and long-term periods. The COS-7 cells, which hail from the African green monkey kidney, have been chosen for this study. A fast data acquisition setup comprising an optical scanning module can be easily attached to the microscope, and it allows observing cell 3D organelle movements and RI variations, with the required temporal resolution. In particular, a more rapid nucleoli rotation than previously reported has been found. The long-term cell monitoring during necrosis reveals significant changes in cell dry mass concentration obtained from recovered RI contrast.