This letter introduces a micro-electromechanical system (MEMS) resonant pressure gauge based on aluminum nitride piezoelectric resonators that can operate in an atmospheric environment. The pressure is measured in terms of the change in the resonant frequency of a double-ended tuning fork (DETF) resonator, where the aluminum nitride thin film serves as both a piezoelectric layer and a passive layer. The resonator exhibits a resonant frequency of 719 kHz and a Q value of 1764 in air. To our knowledge, this Q value surpasses those of previously reported in-air MEMS DETF resonators that operate in the 100 kHz frequency range. The electronic oscillator circuit for the resonant sensor exhibits a phase noise level of -120 dBc/Hz. The measured sensitivity is 16.8 Hz/kPa within the pressure range of 0-90 kPa, which is consistent with the simulation results obtained from finite element modeling. The resolution of the sensor is 14.9 Pa based on Allan variance measurements. This work thus demonstrates a new class of MEMS sensors for use in harsh environments.
Microelectromechanical system (MEMS) cantilever resonators suffer from high motional impedance (Rm). This paper investigates the use of mechanically coupled multi-cantilever piezoelectric MEMS resonators in the resolution of this issue. A double-sided actuating design, which utilizes a resonator with a 2.5 μm thick AlN film as the passive layer, is employed to reduce Rm. The results of experimental and finite element analysis (FEA) show agreement regarding single- to sextuple-cantilever resonators. Compared with a standalone cantilever resonator, the multi-cantilever resonator significantly reduces Rm; meanwhile, the high quality factor (Q) and effective electromechanical coupling coefficient (Kteff2) are maintained. The 30 μm wide quadruple-cantilever resonator achieves a resonance frequency (fs) of 55.8 kHz, a Q value of 10,300, and a series impedance (Rs) as low as 28.6 kΩ at a pressure of 0.02 Pa; meanwhile, the smaller size of this resonator compared to the existing multi-cantilever resonators is preserved. This represents a significant advancement in MEMS resonators for miniaturized ultra-low-power oscillator applications.
30 January 2024 in Journal of Microelectromechanical Systems
It is a longstanding issue that high-order width-extensional (WE) piezoelectric microelectromechanical system (MEMS) resonators suffer low quality factors (Q-factors). In this study, it is observed that the mode distortion occurs in each unit when it couples with each other to constitute the high-order WE-mode resonator, leading to a decreased Q-factor. Based on this finding, we propose a new Q-factor boost strategy by improving mode matching degree between adjacent units from the view of dividing the high-order resonator into units. Both simulation and experimental results show a significant improvement in mode matching degree between adjacent units with varied unit length. Resonator’s Q-factor measured in air improved by 53% compared with the conventional resonator with constant unit length. It is believed that the proposed strategy could apply to other WE-mode MEMS resonators with different orders or dimensions; and Q-factor can be further improved by combining the proposed method with traditional energy reflection methods.2023-0201