Joan Lorente-Piera

Dr. Joan Lorente-Piera


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MCMarlon Xavier Cantillo
Marlon Xavier Cantillo
JLJoan Lorente-Piera
Joan Lorente-Piera
RMRaquel Manrique-Huarte
Raquel Manrique-Huarte
MSMargarita Sánchez-Del-Río
Margarita Sánchez-Del-Río
Nicolas Perez-FernandezNicolas Perez-Fernandez
Nicolas Perez-Fernandez
PIPablo Irimia
Pablo Irimia
Vestibular migraine (VM) commonly causes recurrent vertigo, but diagnosing and managing it can be difficult due to symptom overlap with other vestibular and headache disorders. This review provides a comprehensive update on VM, beginning with the diagnostic criteria established by the International Headache Society and the Bárány Society, who have increased awareness of this condition. While the pathophysiology is not yet completely understood, there is evidence of a complex interaction between the nociceptive and vestibular systems. Treatment approaches are primarily empirical and lack robust, high-quality evidence. Often, antihistamines and benzodiazepines are used for quick symptom relief, while the efficacy of triptans is still uncertain. Preventive measures include lifestyle changes, vestibular rehabilitation, oral migraine prophylactics, Botulinum toxin type A, and, more recently, CGRP-targeted therapies. Due to diagnostic uncertainties and the absence of standardised treatment protocols, further research—particularly randomised controlled trials—is crucial for establishing evidence-based guidelines.

21 August 2024 in Audiology Research
Verified
Journal Article
Open access
PDF file
JLJoan Lorente-Piera
Joan Lorente-Piera
RMRaquel Manrique-Huarte
Raquel Manrique-Huarte
JLJANAINA LIMA
JANAINA LIMA
DCDiego Calavia
Diego Calavia
MMManuel Manrique
Manuel Manrique
Background: Middle ear active implants, such as the Vibrant Soundbridge (VSB), offer an alternative to reconstructive surgery and other implantable hearing aid systems for patients with conductive, mixed, or sensorineural hearing loss. The primary objective of this work is to describe the auditory results obtained with VSB in our patient cohort, measuring the auditory gain in terms of average tonal thresholds and spoken word discrimination at 65 dB. Secondly, auditory gain differences between different types of hearing loss, coupling to the ossicular chain compared to round and oval windows, and the impact of open versus more conservative surgical approaches, were analyzed. Methods: A cross-sectional observational study, with retrospective data collection, was conducted at a tertiary care center. Clinical and audiometric data pre- and post-implantation were included, from patients who underwent VSB device placement surgery between 2001 and 2024. Results: 55 patients with an average age of 62.58 ± 17.83 years and a slight preference in terms of the female gender (52.72%) were included in the study. The average gain in the PTA for all types of hearing loss was 41.56 ± 22.63 dB, while for sensorineural hearing loss (SNHL) the gain was 31.04 ± 8.80 dB. For mixed-conductive hearing loss (C-MHL) a gain of 42.96 ± 17.70 was achieved, notably, in terms of absolute values, at frequencies of 4000 and 6000 Hz, with gains reaching 49.25 ± 20.26 dB at 4 K and 51.16 ± 17.48 dB at 6 K. In terms of spoken word discrimination, for all types of hearing loss, an improvement of 75.20 ± 10.11% was achieved. However, patients with C-MHL exhibited an approximately 13% higher gain compared to those with SNHL (69.32 ± 24.58% vs. 57.79 ± 15.28%). No significant differences in auditory gain were found between open and closed surgical techniques, nor in the proportion of adverse effects, when comparing one technique with the other. Conclusions: The VSB is effective in improving hearing in patients with mixed, conductive, and sensorineural hearing loss, with significant gains at high frequencies, especially through the round window membrane approach. The choice of surgical technique should consider the patient’s anatomical characteristics and specific needs in order to optimize auditory outcomes and minimize postoperative complications.

20 February 2024 in Audiology and Neurotology
Verified
Journal Article
Closed access
PDF file
JLJoan Lorente-Piera
Joan Lorente-Piera
RMRaquel Manrique-Huarte
Raquel Manrique-Huarte
JLJanaina Patricio de Lima
Janaina Patricio de Lima
AHAlicia Huarte-Irujo
Alicia Huarte-Irujo
MMManuel Manrique
Manuel Manrique
Introduction: Bone conduction implants have been indicated for patients with conductive hearing loss, mixed hearing loss, and even profound unilateral sensorineural hearing loss. With the introduction of Bonebridge®, new transcutaneous implant options emerged. The latest is Osia®, a direct-drive variant or active systems, where the implant directly generates and applies vibration to the bone. Materials and Methods: Retrospective study of two cohorts of patients treated with active bone conduction implants at a single center, one with the Bonebridge® device and the other with Osia®. Outcomes: Fourteen patients were included, seven in each group (n = 14). The Bonebridge® group showed an average hearing gain in tonal intelligibility thresholds of 32.43 ± 21.39 dB and a gain in the average intelligibility threshold (with 50% discrimination) of 26.29 ± 19.10 dB. In the Osia® group, there was a gain in average tonal thresholds of 41.49 ± 14.16 dB and 23.72 ± 6.98 dB in average intelligibility thresholds. Both devices contributed to improvements in patients’ quality of life, as assessed with APHAB in all the variables studied in the test. Both devices offer rehabilitation for hearing loss as an alternative to hearing aids. The Osia® system shows statistically significant (p < 0.05) improvements in mid and high frequencies, but Bonebridge® slightly outperforms in speech understanding at 50%. Differences in average tonal thresholds and quality of life are not statistically significant. Conclusions: While auditory improvement is observed postimplantation, other aspects, such as intelligibility thresholds and quality of life, lack statistical significance. Given the limited experience with Osia® and the small sample size, the choice of the device should be personalized. Although the literature is inconsistent due to small sample sizes and variable approaches, some studies suggest potential advantages of the Osia® system, especially in speech comprehension in different environments and greater hearing gain compared to Bonebridge®.

12 April 2024 in Audiology Research
Verified
Journal Article
Open access
PDF file
JLJoan Lorente-Piera
Joan Lorente-Piera
CPCarlos Prieto-Matos
Carlos Prieto-Matos
RMRaquel Manrique-Huarte
Raquel Manrique-Huarte
OGOctavio Garaycochea
Octavio Garaycochea
PDPablo Domínguez
Pablo Domínguez
MMManuel Manrique
Manuel Manrique
Introduction: We present a series of six cases whose clinical presentations exhibited audiovestibular manifestations of a third mobile window mechanism, bearing a reasonable resemblance to Ménière’s disease and otosclerosis. The occurrence of these cases in such a short period has prompted a review of the underlying causes of its development. Understanding the pathophysiology of third mobile window syndrome and considering these entities in the differential diagnosis of conditions presenting with vertigo and hearing loss with slight air-bone gaps is essential for comprehending this group of pathologies. Materials and Methods: A descriptive retrospective cohort study of six cases diagnosed at a tertiary center. All of them went through auditive and vestibular examinations before and after a therapeutic strategy was performed. Results: Out of 84 cases of dehiscences described in our center during the period from 2014 to 2024, 78 belonged to superior semicircular canal dehiscence, while 6 were other otic capsule dehiscences. Among these six patients with a mean age of 47.17 years (range: 18–73), all had some form of otic capsule dehiscence with auditory and/or vestibular repercussions, measured through hearing and vestibular tests, with abnormalities in the results in five out of six patients. Two of them were diagnosed with Ménière’s disease (MD). Another two had cochleo-vestibular hydrops without meeting the diagnostic criteria for MD. In two cases, the otic capsule dehiscence diagnosis resulted from an intraoperative complication due to a gusher phenomenon, while in one case, it was an accidental radiological finding. All responded well to the proposed treatment, whether medical or surgical, if needed. Conclusions: Otic capsule dehiscences are relatively new and unfamiliar entities that should be considered when faced with cases clinically suggestive of Ménière’s disease, with discrepancies in complementary tests or a poor response to treatment. While high-sensitivity and specificity audiovestibular tests exist, completing the study with imaging, especially petrous bone CT scans, is necessary to locate and characterize the otic capsule defect responsible for the clinical presentation.

28 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JLJoan Lorente-Piera
Joan Lorente-Piera
RMRaquel Manrique-Huarte
Raquel Manrique-Huarte
Nicolas Perez-FernandezNicolas Perez-Fernandez
Nicolas Perez-Fernandez
DCDiego Calavia
Diego Calavia
MVMarcos Jiménez Vázquez
Marcos Jiménez Vázquez
MMManuel Manrique
Manuel Manrique
Background/Objectives: Multiple dehiscences of the otic capsule can exhibit behavior similar to Ménière’s disease, not only from a clinical perspective but also in the results of audiovestibular tests. The main objective of this study is to characterize third mobile window etiologies from an audiovestibular perspective, while also evaluating the therapeutic response to four different treatment protocols. Furthermore, we aim to explore a potential association with the development of radiologically defined endolymphatic hydrops (EH). Methods: This is a retrospective cohort study conducted from 2017 to 2024 at a tertiary-level otology and otoneurology unit. All patients underwent pure tone audiometry, vHIT, cVEMP, and oVEMP. Some of these patients, selected under rigorous inclusion criteria based on clinical and audiometric findings, were subjected to a 4-h delayed intravenous gadolinium-enhanced 3D-FLAIR MRI. Results: We obtained a sample of 86 patients, with a mean age of 52.2 ± 7.64 years: 62.76% were female (n = 54) and 37.21% were male (n = 32); 88.37% (n = 76) were diagnosed with superior semicircular canal dehiscence syndrome (SSCDS), while 11.62% (n = 10) had other forms of otic capsule dehiscence. The most common symptom observed was unsteadiness (44%). While surgery is the only curative treatment, other medical treatments, such as acetazolamide, also helped reduce symptoms such as autophony, falls, instability, and vertigo attacks, with a relative risk reduction (RRR) exceeding 75% (95% CI, p < 0.05). The results of the MRI in EH sequences indicate that 7.89% of the patients diagnosed with SSCDS also developed radiological EH, compared to 40.00% of the patients with other otic capsule dehiscences, a difference that was statistically significant (p = 0.0029. Conclusions: Otic capsule dehiscences are relatively unknown conditions that require clinical diagnosis. Although VEMP testing is useful, imaging studies are necessary to localize and characterize the defect, most commonly found in the superior semicircular canal. We should consider these dehiscences in cases where there is a suspicion of EH development. Further research, including in vivo neuroimaging studies using hydrops sequences, is required to better understand their relationship to potential Ménière’s disease.

21 February 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JLJoan Lorente-Piera
Joan Lorente-Piera
EPElena Prieto
Elena Prieto
AMAngel Ramos de Miguel
Angel Ramos de Miguel
MMManuel Manrique
Manuel Manrique
Nicolas Perez-FernandezNicolas Perez-Fernandez
Nicolas Perez-Fernandez
RMRaquel Manrique-Huarte
Raquel Manrique-Huarte
Introduction: In patients refractory to vestibular rehabilitation in the management of bilateral vestibulopathy, the cochleo-vestibular implant has emerged as a viable alternative to enhance both audiovestibular function and quality of life. The main objective of this study is to pioneer the use of PET to assess cortical modifications in patients with cochleo-vestibular implants, aiming to evaluate the safety and functional improvements in individuals with bilateral vestibulopathy and severe to profound hearing loss. Methods: A phase I pilot clinical trial was conducted with participants who received a BIONIC-VEST CI24RE cochleo-vestibular implant, with pre- and post-implantation assessments conducted for twelve months. Audiovestibular testing and two PET studies with 18F-FDG under baseline conditions and with active stimulus to observe cortical-level differences were performed. Results: Five patients were included in the study, all of them treated with a cochleo-vestibular implant, none of whom presented postoperative adverse effects. Audiologically, the mean post-implant gain was 56.63 ± 14.53 dB and 50.40 ± 35.54% in terms of speech intelligibility. From a vestibular perspective, the most remarkable findings were observed at the graviceptive pathway level, where a mean posturographic improvement was observed, with a sensory organization test score of 24.20 ± 13.74 and a subjective visual vertical of 1.57° ± 0.79°, achieving, in most cases, results within the normal range (<2.3°) by the end of the follow-up. PET images confirmed that with the electrical stimulus active (implant ON), there was a supratentorial activation pattern, particularly in areas related to somatosensory integration, emotional regulation, and autonomic control. Conclusions: The BIONIC-VEST implant significantly improved the vestibular system, particularly the graviceptive pathway, enhancing balance and SVV and reducing fall risk. PET revealed distinct uptake patterns in baseline and activated conditions, highlighting a cortical-level response with the use of the cochleo-vestibular implant.