Fabian Gilbert

Dr. Fabian Gilbert


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MLMarkus Laubach
Markus Laubach
FHFrank Hildebrand
Frank Hildebrand
SSSinduja Suresh
Sinduja Suresh
MWMichael Wagels
Michael Wagels
PKPhilipp Kobbe
Philipp Kobbe
Dietmar Werner HutmacherDietmar Werner Hutmacher
Dietmar Werner Hutmacher
The treatment of bone defects remains a challenging clinical problem with high reintervention rates, morbidity, and resulting significant healthcare costs. Surgical techniques are constantly evolving, but outcomes can be influenced by several parameters, including the patient’s age, comorbidities, systemic disorders, the anatomical location of the defect, and the surgeon’s preference and experience. The most used therapeutic modalities for the regeneration of long bone defects include distraction osteogenesis (bone transport), free vascularized fibular grafts, the Masquelet technique, allograft, and (arthroplasty with) mega-prostheses. Over the past 25 years, three-dimensional (3D) printing, a breakthrough layer-by-layer manufacturing technology that produces final parts directly from 3D model data, has taken off and transformed the treatment of bone defects by enabling personalized therapies with highly porous 3D-printed implants tailored to the patient. Therefore, to reduce the morbidities and complications associated with current treatment regimens, efforts have been made in translational research toward 3D-printed scaffolds to facilitate bone regeneration. Three-dimensional printed scaffolds should not only provide osteoconductive surfaces for cell attachment and subsequent bone formation but also provide physical support and containment of bone graft material during the regeneration process, enhancing bone ingrowth, while simultaneously, orthopaedic implants supply mechanical strength with rigid, stable external and/or internal fixation. In this perspective review, we focus on elaborating on the history of bone defect treatment methods and assessing current treatment approaches as well as recent developments, including existing evidence on the advantages and disadvantages of 3D-printed scaffolds for bone defect regeneration. Furthermore, it is evident that the regulatory framework and organization and financing of evidence-based clinical trials remains very complex, and new challenges for non-biodegradable and biodegradable 3D-printed scaffolds for bone regeneration are emerging that have not yet been sufficiently addressed, such as guideline development for specific surgical indications, clinically feasible design concepts for needed multicentre international preclinical and clinical trials, the current medico-legal status, and reimbursement. These challenges underscore the need for intensive exchange and open and honest debate among leaders in the field. This goal can be addressed in a well-planned and focused stakeholder workshop on the topic of patient-specific 3D-printed scaffolds for long bone defect regeneration, as proposed in this perspective review.

1 December 2020 in JPRAS Open
Verified
Journal Article
Open access
KSKarsten Schmidt
Karsten Schmidt
MJMichael Jakubietz
Michael Jakubietz
RMRainer Meffert
Rainer Meffert
FGFabian Gilbert
Fabian Gilbert
MJMartin Jordan
Martin Jordan
RJRafael Jakubietz
Rafael Jakubietz
The reverse sural artery flap (RSAF) was first described approximately four decades ago and has since been used frequently for reconstruction of soft tissue defects in the distal part of the leg. Although the popularity of this flap never reached the extent of that of free perforator flaps, it still serves as a reliable alternative. This has been demonstrated by the increased rate of publication on the technique in recent years. The number of authors reporting data has risen up to 20 reports a year.

28 December 2017 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
FGFabian Gilbert
Fabian Gilbert
DKDetlef Klein
Detlef Klein
AWAndreas Max Weng
Andreas Max Weng
HKHerbert Köstler
Herbert Köstler
BSBenedikt Schmitz
Benedikt Schmitz
DBDirk Böhm
Dirk Böhm
Fatty Degeneration (FD) of the rotator cuff muscles influences functional and anatomical outcome after rotator cuff repair. The MRI based estimation of fatty degeneration is the gold standard. There is some evidence that Ultrasound elastography (EUS) can detect local differences of tissue stiffness in muscles and tendons. Shear-wave elastography (SWE) was evaluated to determine the extent to which shear wave velocity was associated with measures of fatty degeneration. MRI-spectroscopic fat measurement was used as a reference to quantify the amount of fat in the muscle belly. Forty-two patients underwent SWE of the supraspinatus muscles at its thickest diameter. After ultrasound evaluation an MRI-spectroscopic fat measurement of the supraspinatus muscle was performed using the SPLASH-technique. A gel filled capsule was used to locate the measured area in the MRI. The values of shear wave velocity (SWV) measured with SWE and spectroscopic fat measurement were correlated statistically using Pearson’s correlation test. Correlation of the fat amount measured with MRI-spectroscopy and the SWV measured with SWE was ρ =0.82. Spectroscopic measured fat ratio of the supraspinatus muscle ranged from 0% to 77.41% and SWV from 1.59 m/s to 5.32 m/s. In 4 patients no sufficient SWE could be performed, these individuals showed a larger diameter of the overlying soft tissue. SWV measured with SWE showed a good correlation with MRI spectroscopic fat amount of the supraspinatus muscle. These preliminary data suggest that SWE may be a sufficient tool in detecting and estimating the amount of fatty degeneration in the supraspinatus muscle in real time. Large overlying soft tissue may be a limitation in performing sufficient EUS. Ethical Committee Approval: Nr: 156/14 Date 12th August 2014. Level of Evidence: III.

22 August 2016 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
FGFabian Gilbert
Fabian Gilbert
DBDirk Böhm
Dirk Böhm
LELars Eden
Lars Eden
JSJonas Schmalzl
Jonas Schmalzl
RMRainer H. Meffert
Rainer H. Meffert
DZDirk Ziegler
Dirk Ziegler
The Goutallier Classification is a semi quantitative classification system to determine the amount of fatty degeneration in rotator cuff muscles. Although initially proposed for axial computer tomography scans it is currently applied to magnet-resonance-imaging-scans. The role for its clinical use is controversial, as the reliability of the classification has been shown to be inconsistent. The purpose of this study was to compare the semi quantitative MRI-based Goutallier Classification applied by 5 different raters to experimental MR spectroscopic quantitative fat measurement in order to determine the correlation between this classification system and the true extent of fatty degeneration shown by spectroscopy. MRI-scans of 42 patients with rotator cuff tears were examined by 5 shoulder surgeons and were graduated according to the MRI-based Goutallier Classification proposed by Fuchs et al. Additionally the fat/water ratio was measured with MR spectroscopy using the experimental SPLASH technique. The semi quantitative grading according to the Goutallier Classification was statistically correlated with the quantitative measured fat/water ratio using Spearman’s rank correlation. Statistical analysis of the data revealed only fair correlation of the Goutallier Classification system and the quantitative fat/water ratio with R = 0.35 (p < 0.05). By dichotomizing the scale the correlation was 0.72. The interobserver and intraobserver reliabilities were substantial with R = 0.62 and R = 0.74 (p < 0.01). The correlation between the semi quantitative MRI based Goutallier Classification system and MR spectroscopic fat measurement is weak. As an adequate estimation of fatty degeneration based on standard MRI may not be possible, quantitative methods need to be considered in order to increase diagnostic safety and thus provide patients with ideal care in regard to the amount of fatty degeneration. Spectroscopic MR measurement may increase the accuracy of the Goutallier classification and thus improve the prediction of clinical results after rotator cuff repair. However, these techniques are currently only available in an experimental setting.

24 June 2025 in Journal of Medical Systems
Verified
Journal Article
Open access
PDF file
KWKonstantin Wehrkamp
Konstantin Wehrkamp
RMRainer Christoph Miksch
Rainer Christoph Miksch
HPHans Polzer
Hans Polzer
FGFabian Gilbert
Fabian Gilbert
MBMarkus Buehner
Markus Buehner
RNRouven Neudeck
Rouven Neudeck
This systematic literature review aimed to examine the effects of Virtual Reality (VR), Augmented Reality (AR), and Mixed Reality (MR) head-mounted displays (HMDs) on patient understanding, satisfaction, and anxiety during preoperative informed consent. Following PRISMA-P guidelines (Prospero ID: CRD42023487281), we searched four major databases from their inception to March 24, 2023. Studies were eligible if they utilized VR, AR, or MR HMDs to visualize patient-specific data during informed consent across any medical specialty. Two reviewers independently conducted all steps of the systematic review process, and the risk of bias was assessed using the Methodological Index for Non-Randomized Studies (MINORS). Sixteen studies involving a total of 1067 patients were identified and included. These comprised 10 Randomized Controlled Trials (RCTs) and 6 Non-Randomized Controlled Trials (non-RCTs), including one comparative study and five non-comparative studies. The literature reviewed was heterogeneous, encompassing patients with diverse conditions across various medical specialties, including cardiology, neurosurgery, transplantation surgery, vascular surgery, plastic surgery, and urology. The results demonstrated that VR, AR, and MR HMDs positively impact patient understanding, satisfaction, and anxiety reduction. Notably, the findings were more consistent for VR HMDs compared to the limited and variable literature on AR and MR HMDs. VR, AR, and MR HMDs generally show positive effects on patient understanding, satisfaction, and anxiety in preoperative informed consent. While VR HMDs consistently yield positive outcomes, further research is needed to elucidate the effectiveness and benefits of AR and MR HMDs in preoperative consultations.

20 November 2018 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
FGFabian Gilbert
Fabian Gilbert
CSC. Schneemann
C. Schneemann
CSC. J. Scholz
C. J. Scholz
RKR. Kickuth
R. Kickuth
RMR. H. Meffert
R. H. Meffert
ABA. Busch
A. Busch
Vascular damage in polytrauma patients is associated with high mortality and morbidity. Therefore, specific clinical implications of vascular damage with fractures in major trauma patients are reassessed. This comprehensive nine-year retrospective single center cohort study analyzed demography, laboratory, treatment and outcome data from 3689 patients, 64 patients with fracture-associated vascular injuries were identified and were compared to a control group. Results: Vascular damage occurred in 7% of patients with upper and lower limb and pelvic fractures admitted to the trauma room. Overall survival was 80% in pelvic fracture and 97% in extremity fracture patients and comparable to non-vascular trauma patients. Additional arterial damage required substantial fluid administration and was visible as significantly anemia and disturbed coagulation tests upon admission. Open procedures were done in over 80% of peripheral extremity vascular damage. Endovascular procedures were predominant (87%) in pelvic injury. Vascular damage is associated with high mortality rates especially in combination with pelvic fractures. Initial anemia, disturbed coagulation tests and the need for extensive pre-clinical fluid substitution were observed in the cohort with vascular damage. Therefore, fast diagnosis and early interventional and surgical procedures are necessary to optimize patient-specific outcome.