Andreas Max Weng

Andreas Max Weng

Auto-generated profile, based on publicly available information

Andreas Max Weng

Department of Diagnostic and Interventional Radiology University Hospital Würzburg Würzburg Germany

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Radiology
Verified
Journal Article
Closed access
AKAleksander Kosmala
Aleksander Kosmala
AWAndreas Max Weng
Andreas Max Weng
AHAnke Heidemeier
Anke Heidemeier
BKBernhard Krauss
Bernhard Krauss
SKStefan Knop
Stefan Knop
BPBernhard Petritsch
Bernhard Petritsch
Dual-energy virtual noncalcium CT images provide excellent diagnostic performance in visual and region of interest–based evaluation of bone marrow infiltration in patients with multiple myeloma. PurposeTo determine the diagnostic performance of dual-energy computed tomography (CT) for detection of bone marrow (BM) infiltration in patients with multiple myeloma by using a virtual noncalcium (VNCa) technique.Materials and MethodsIn this prospective study, 34 consecutive patients with multiple myeloma or monoclonal gammopathy of unknown significance sequentially underwent dual-energy CT and magnetic resonance (MR) imaging of the axial skeleton. Two independent readers visually evaluated standard CT and color-coded VNCa images for the presence of BM involvement. MR imaging served as the reference standard. Analysis on the basis of the region of interest (ROI) of VNCa CT numbers of infiltrated (n = 75) and normal (n = 170) BM was performed and CT numbers were subjected to receiver operating characteristic analysis to calculate cutoff values.ResultsIn the visual analysis, VNCa images had an overall sensitivity of 91.3% (21 of 23), specificity of 90.9% (10 of 11), accuracy of 91.2% (31 of 34), positive ...

1 July 2017 in Radiology
Verified
Journal Article
Closed access
BPBernhard Petritsch
Bernhard Petritsch
AKAleksander Kosmala
Aleksander Kosmala
AWAndreas M. Weng
Andreas M. Weng
BKBernhard Krauss
Bernhard Krauss
AHAnke Heidemeier
Anke Heidemeier
TBThorsten A. Bley
Thorsten A. Bley
Visual and quantitative analyses of dual-energy virtual noncalcium images had excellent diagnostic performance in the depiction of traumatic bone marrow edema in patients with vertebral compression fractures. Purpose To assess the diagnostic performance of a third-generation dual-energy computed tomographic (CT) virtual noncalcium (VNCa) technique for detection of traumatic bone marrow edema in patients with vertebral compression fractures. Materials and Methods This prospective study was approved by the institutional review board. Informed consent was obtained from all participants. Twenty-two consecutive patients with 37 morphologic vertebral fractures were studied between October 2015 and May 2016. All patients underwent dual-energy CT (90 kV and 150 kV with a tin filter) and 3-T magnetic resonance (MR) imaging. Two independent readers visually evaluated all vertebral bodies (n = 163) for the presence of abnormal bone marrow attenuation on VNCa images by using color-coded maps and performed a quantitative analysis of CT numbers on VNCa images. MR images served as the reference standard. CT numbers were subjected to receiver operating characteristic analysis to calculate cutoff values. Results In the visual ...

7 June 2018 in European Radiology
Verified
Journal Article
Closed access
PDF file
AKAleksander Kosmala
Aleksander Kosmala
AWAndreas Max Weng
Andreas Max Weng
BKBernhard Krauss
Bernhard Krauss
SKStefan Knop
Stefan Knop
TBThorsten Alexander Bley
Thorsten Alexander Bley
BPBernhard Petritsch
Bernhard Petritsch

24 September 2010 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
DSDaniel Stäb
Daniel Stäb
CRChristian Oliver Ritter
Christian Oliver Ritter
FBFelix A. Breuer
Felix A. Breuer
AWAndreas Max Weng
Andreas Max Weng
DHDietbert Hahn
Dietbert Hahn
HKHerbert Köstler
Herbert Köstler
Exciting multiple slices at the same time, “controlled aliasing in parallel imaging results in higher acceleration” (CAIPIRINHA) and “phase‐offset multiplanar” have shown to be very effective techniques in 2D multislice imaging. Being provided with individual rf phase cycles, the simultaneously excited slices are shifted with respect to each other in the FOV and, thus, can be easily separated. For SSFP sequences, however, similar rf phase cycles are required to maintain the steady state, impeding a straightforward application of phase‐offset multiplanar or controlled aliasing in parallel imaging results in higher acceleration. In this work, a new flexible concept for applying the two multislice imaging techniques to SSFP sequences is presented. Linear rf phase cycles are introduced providing both in one, the required shift between the slices and steady state in each slice throughout the whole measurement. Consequently, the concept is also appropriate for real‐time and magnetization prepared imaging. Steady state properties and shifted banding behavior of the new phase cycles were investigated using simulations and phantom experiments. Moreover, the concept was applied to perform whole heart myocardial perfusion SSFP imaging as well as real‐time and cine SSFP imaging with increased coverage. Showing no significant penalties in SNR or image quality, the results successfully demonstrate the general applicability of the concept. Magn Reson Med, 2010.

1 April 2017 in Radiology
Verified
Journal Article
Closed access
SVSimon Veldhoen
Simon Veldhoen
AWAndreas M. Weng
Andreas M. Weng
JKJanine Knapp
Janine Knapp
AKAndreas Steven Kunz
Andreas Steven Kunz
DSDaniel Stäb
Daniel Stäb
TBThorsten A. Bley
Thorsten A. Bley
Self-gated non–contrast-enhanced functional lung MR imaging allows for site-resolved assessment of quantitative pulmonary ventilation in patients with cystic fibrosis without contrast material application or breath holds. PurposeTo assess the clinical feasibility of self-gated non–contrast-enhanced functional lung (SENCEFUL) magnetic resonance (MR) imaging for quantitative ventilation (QV) imaging in patients with cystic fibrosis (CF).Materials and MethodsTwenty patients with CF and 20 matched healthy volunteers underwent functional 1.5-T lung MR imaging with the SENCEFUL imaging approach, in which a two-dimensional fast low-angle shot sequence is used with quasi-random sampling. The lungs were manually segmented on the ventilation-weighted images to obtain QV measurements, which were compared between groups. QV values of the patients were correlated with results of pulmonary function testing. Three radiologists rated the images for presence of ventilation deficits by means of visual inspection. Mann-Whitney U tests, receiver operating characteristic analyses, Spearman correlations, and Gwet agreement coefficient analyses were used for statistical analysis.ResultsQV of the entire lungs was lower for patients with CF than f...

4 November 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
LPL. Mendes Pereira
L. Mendes Pereira
TWT. Wech
T. Wech
AWA.M. Weng
A.M. Weng
CKC. Kestler
C. Kestler
SVSimon Veldhoen
Simon Veldhoen
HKH. Köstler
H. Köstler