Nikolay Kurtev

Dr. Nikolay Kurtev

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
NKNikolay Kurtev
Nikolay Kurtev
Ivaylo Milanov PandievIvaylo Milanov Pandiev
Ivaylo Milanov Pandiev
Supercapacitors have garnered significant interest in recent years due to their high power density, rapid charge/discharge rates, and long cycle life. MXenes, a family of two-dimensional (2D) transition metal carbides/nitrides, have emerged as promising electrode materials for supercapacitors. However, one major challenge associated with incorporating MXenes in supercapacitor structures is the occurrence of sticking, wherein individual MXene flakes agglomerate, leading to reduced electrode performance. This review paper discusses various causes of sticking and approaches to preventing it, offering insights into the design and development of high-performance MXene-based supercapacitors. The morphology and size of MXene flakes, flake surface chemistry, thickness, surface area/volume ratio, electrode processing techniques (including solvent selection, additives incorporation, and deposition technology), and environmental factors were shown to be the basic factors resulting in sticking of MXene sheets. Among the strategies to mitigate this challenge, surface functionalization and passivation, integration with polymer matrices or carbon nanomaterials, and electrode processing optimization were considered. Possible paths for optimization and future directions of study, such as novel MXene compositions, understanding of interfaces and electrode–electrolyte interactions, development of advanced electrode architectures, and integration of energy storage systems, were assumed.

31 May 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ivaylo Milanov PandievIvaylo Milanov Pandiev
Ivaylo Milanov Pandiev
NTNikolay Tomchev
Nikolay Tomchev
NKNikolay Kurtev
Nikolay Kurtev
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
This paper presents a comprehensive review of the design and implementation methods of low-power piezoelectric energy harvesting circuits, which in the last few years have gained an extremely large range of applications like the power sources of wearable electronic devices, such as biometrical sensors. Before examining the electronic circuitries of the self-supplied power devices, an overview of the structure, equivalent electrical circuits, and basic parameters of the piezoelectric generators and MEMSs as energy harvesting elements is presented. The structure of energy storage elements (parallel-plate capacitors and thin-film supercapacitors), suitable for this type of application, is also presented. The description of these components from an electrical point of view allows them to be easily workable when connected to the various power conversion electronic circuits. Based on an overview of the structure and the principles of operation, as well as some analytical expressions for energy efficiency evaluation, a comprehensive comparative analysis is presented. Depending on the advantages and disadvantages of the known circuit configurations, the basic electrical and design parameters are systematized in tabular form. Practical realizations of piezoelectric power conversion circuits are also presented in graphic form, ensuring the optimal value of energy efficiency and compactness in the construction of the devices.

26 December 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Ivaylo Milanov PandievIvaylo Milanov Pandiev
Ivaylo Milanov Pandiev
HAHristo Antchev
Hristo Antchev
NKNikolay Kurtev
Nikolay Kurtev
NTNikolay Tomchev
Nikolay Tomchev
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
Improving microelectronic technologies has created various micro-power electronic devices with different practical applications, including wearable electronic modules and systems. Furthermore, the power sources for wearable electronic devices most often work with electrical energy obtained from the environment without using standard batteries. This paper presents the structure and electrical parameters of a circuit configuration realized as a prototype of a low-power AC-DC conversion circuit intended for use as a power supply device for signal processing systems that test various biomedical parameters of the human body. The proposed prototype has to work as a wearable self-powered system that transfers electrical energy obtained through mechanical vibrations in the piezoelectric generator. The obtained electrical energy is used to charge a single low-voltage supercapacitor, which is used as an energy storage element. The proposed circuit configuration is realized with discrete components consisting of a low-voltage bridge rectifier, a low-pass filter, a DC-DC step-down (buck) synchronous converter, a power-controlling system with an error amplifier, and a window detector that produces a “power-good” signal. The power-controlling system allows tuning the output voltage level to around 1.8 V, and the power dissipation for it is less than 0.03 mW. The coefficient of energy efficiency achieved up to 78% for output power levels up to 3.6 mW. Experimental testing was conducted to verify the proposed AC-DC conversion circuit’s effectiveness, as the results confirmed the preliminary theoretical analyses and the derived analytical expressions for the primary electrical parameters.

9 March 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Ivaylo Milanov PandievIvaylo Milanov Pandiev
Ivaylo Milanov Pandiev
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
NKNikolay Kurtev
Nikolay Kurtev
SRStefan Milkov Rizanov
Stefan Milkov Rizanov
The improvement of microelectronic technologies and the practical application of some new materials has resulted in the realization of various highly efficient thin-film energy harvesters in the last few years. Self-powered supplies intended to work with thin-film harvesters have been developed. This type of power supply with integrated various thin-film harvesters has proven to be very suitable for providing electrical energy for wearable electronic sensor systems, with practical applications for implementing personalized medicine through continuously monitoring an individual’s state of health. The application of wearable electronics in medicine will become increasingly important in the next few years, as it can support timely decision-making, especially in high-risk patients. This paper presents a review and comparative analysis of the optimal circuit configurations used to design power supply devices with discrete and integrated components, obtaining electrical power from various thin-film piezoelectric generators, and storing electrical energy in low-power multilayer supercapacitors. Based on an analysis of the principle of operation of the selected circuit configurations, analytical expressions for the basic static and dynamic parameters have been obtained, taking into account the peculiarities of their integration with the biomedical signal processing system. Advantages and weaknesses are analyzed through simulation testing for each configuration, as the prospects for improvement are outlined. Also, for each group of circuit configurations, the key parameters and characteristics of recent high-impact papers, especially those focusing on low-power applications, are presented and analyzed in tabular form. As a result of the analysis of the various circuit configurations, some analytical recommendations have been defined regarding the optimal selection of passive and active elements, which can contribute to a better understanding of the design principles of battery-free power supplies converting electrical energy from some specific recently developed thin-film energy harvesters.

16 May 2026 in Electronics
Verified
Journal Article
Open access
PDF file
BBBorislav Bonev
Borislav Bonev
Ivaylo Milanov PandievIvaylo Milanov Pandiev
Ivaylo Milanov Pandiev
NKNikolay Kurtev
Nikolay Kurtev
This work presents a reliability-oriented design methodology for LC oscillators, focusing on Colpitts configurations implemented by a bipolar transistor. A nonlinear steady-state analytical framework is used as a practical design tool to determine the resonant tank parameters, loop gain conditions, and the dependence of oscillation amplitude on the operating conditions. Based on this analysis, a systematic sizing procedure is developed, in which the LC tank is designed and statistically characterized prior to amplifier and bias selection. The influence of component tolerances, temperature variation, supply voltage deviation, and load changes is quantified through statistical Monte Carlo analysis. To overcome the amplitude instability observed in the classical Colpitts topology, an automatic gain control (AGC) block is introduced that directly regulates the transistor transconductance, eliminating the need for individual amplitude adjustment. The simulation results demonstrate that, while the conventional Colpitts oscillator exhibits output amplitude variations of approximately ±30% under realistic parameter deviations, the proposed AGC-enhanced design limits worst-case amplitude variation to within ±10% using only standard tolerance components. A hardware prototype was developed to experimentally validate the methodology over wide variations in resonant tank parameters, amplifier bias conditions, and external load. The combined analytical, statistical, and experimental results confirm that the proposed approach simplifies the design process, improves robustness, and enables predictable, trimming-free oscillator operation suitable for mass-produced electronic systems.

9 October 2026 in Electronics
Verified
Journal Article
Open access
PDF file
BBBorislav Bonev
Borislav Bonev
Ivaylo Milanov PandievIvaylo Milanov Pandiev
Ivaylo Milanov Pandiev
NKNikolay Kurtev
Nikolay Kurtev
Stable, programmable amplitude control in self-sustained sinusoidal oscillators is complicated by the nonlinear relationship between loop gain and steady-state amplitude and by variations in circuit parameters and operating conditions. This paper presents a topology-adaptable methodology for digitally assisted automatic gain control in analog LC and RC oscillators while preserving their physical frequency-selective networks. The architecture combines topology-specific coarse and fine adjustment of an analog parameter with common measurement, calibration, temperature compensation, and embedded control functions. A user-assisted procedure characterizes the complete peak-detector path at four reference amplitudes using a second-order least-squares polynomial calculated autonomously by the microcontroller. Amplitude-dependent temperature compensation is derived from measurements at three reference levels. The methodology is demonstrated using an operational-amplifier Wien-bridge oscillator and a BJT-based Colpitts oscillator with an analog inner control loop. Measurements from 20 °C to 50 °C show relative control errors below 3% at all investigated points within the respective base-calibration intervals. Larger errors occur at measured points below the first calibration levels, where polynomial extrapolation is required. Startup and setpoint-change measurements further characterize the distinct dynamics of the two control strategies. The results confirm that the common framework is applicable to oscillators with fundamentally different amplitude-establishment mechanisms.