Borislav Bonev

Dr. Borislav Bonev

Department of Electronics, Technical University of Sofia, Sofia, Sofia-Grad, Bulgaria
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018
Verified
Conference Paper
Closed access
ASAnna Stoynova
Anna Stoynova
BBBorislav Bonev
Borislav Bonev
NBNikolay Brayanov
Nikolay Brayanov
The possibilities and specifics of the application of the thermographic non-destructive diagnostics in the development and production of PCBs are analyzed. Methods for evaluation of the temperature regimes of the electronic elements and their impact on the reliability of the PCB are noted. The problems in determining the reliability of the PCB elements according to thermographic diagnostics data are presented. A methodology for reliability evaluation of both individual components and PCBs in the operating temperature range is proposed. Thermographic measurements of test and real operating PCBs were performed. An approach is presented to automate the process of thermal control using infrared.

1 May 2019
Verified
Conference Paper
Closed access
NVNikolay Vakrilov
Nikolay Vakrilov
ASAnna Stoynova
Anna Stoynova
BBBorislav Bonev
Borislav Bonev
In this paper, a comparative analysis of two methods for evaluation of the thermal behavior of metal core printed circuit boards (MCPCB)for a LED lighting device is performed-modeling and measuring. Digital modeling and CFD simulations capabilities for the prognosis of heat-physical processes in different PCBs construction of LED modules and experimental capabilities of noncontact measurements methods are investigated and compared. Correlations between thermal surface distribution and design parameters obtained with digital thermal models are verified by thermographic measurements. It has been shown that a verification process of up to 5 % accuracy is obtained by taking standard measures to compensate the main factors affecting the thermography.

1 May 2019
Verified
Conference Paper
Closed access
ASAnna Stoynova
Anna Stoynova
NNNencho Nenov
Nencho Nenov
BBBorislav Bonev
Borislav Bonev
DYDesislava Yosifova
Desislava Yosifova
This work is an important step in the building of a Checkpoint System - national system for monitoring and control of rolling stock during motion, for the needs of the railway infrastructure in Bulgaria. Implementation of the system ensures a high level of safety of train movements and prevention of railway incidents. A basic function of the whole system is the identification of unacceptable overheating of rolling stocks' components mainly wheel bearing assemblies and brake sets, and/or other components of a rail vehicle. The chosen approach involves the use of non-contact infrared temperature sensors. It can be used also thermal imaging cameras instead of individual temperature sensors, which increase the possibilities of the temperature status monitoring of the railway rolling stock. A concept, model and kit of a real-time system for thermal imaging have been developed and presented in the present paper. In order to optimize the efficiency of the overall system, a techno-economic analysis has been made.

8 September 2016
Verified
Conference Paper
Closed access
ASAnna Stoynova
Anna Stoynova
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
GDGeorgi Dobrikov
Georgi Dobrikov
BBBorislav Bonev
Borislav Bonev
In this work, variation of the main electrical parameters of flexible organic light-emitting diodes (FOLEDs) is studied as a function of the thermal conditions. Tested structures are consisted of polyethylene terephthalate (PET) as a flexible substrate, indium-tin oxide transparent conductive anodes, polyphenylene vinylene derivative based emissive films and aluminum cathodes. Thermal degradation analysis of the FOLEDs characteristics is performed by IR thermography in broad range of voltages and driving current densities at different temperatures. The study of thermal distribution with the time provides important information for the thermal events in the operating FOLED, as well as for the local temperature change, due to the presence of hidden defects. CFD thermal simulations of two types of test FOLED samples were conducted. Experimental measurements of the distribution of surface temperature of the samples were carried out with an infrared camera. The obtained difference between the simulated and measured values is not greater than 5 °C at the beginning of degradation processes.

13 September 2023
Verified
Conference Paper
Closed access
ASAnna Stoynova
Anna Stoynova
BBBorislav Bonev
Borislav Bonev
SRStefan Rizanov
Stefan Rizanov
NKNadezhda Kafadarova
Nadezhda Kafadarova
SSSotir Sotirov
Sotir Sotirov
The paper analyzes the approach and key considerations in using infrared thermography to remotely identify key internal characteristics of batteries. The experimental results of the study, which concerns two different types of batteries - lead-acid and lithium-ion (designated as "good" and "bad", according to certain criteria), promises the possibility for implementing automated remote diagnostics in real-world operating conditions, allowing for the evaluation of battery performance and preemptive determination of the type of potential defect that has occurred.

30 March 2022 in International Journal of Circuits, Systems and Signal Processing
Verified
Journal Article
Closed access
ASAnna Stoynova
Anna Stoynova
BBBorislav Bonev
Borislav Bonev
This paper examines the impact of post-processing of lock-in thermographic measurement data on the ability to detect and characterize in terms of geometric dimensions and location of specific types of defects in MCM-L. A thermal 3D model of a test specimen with hidden artificial defects is used and simulated lock-in thermography measurement is performed. Qualitative and quantitative assessment was performed of the correct detection and geometric dimensions characterization of the defects. The Shape Difference (SD) criteria was defined and used for qualitative and quantitative assessment of the confidence detection and characterization of defects in MCM-L. A Window Sliding Offset (WSO) approach is performed as method for improvement of the defects characterization quality. This study revel that providing information on the depth and shape of defects through the combined use of infrared thermography measurement and 3D thermal modeling can be used to determine the desired confidence levels of defects detection.