Baolong Nguyen Phung

Mr. Baolong Nguyen Phung

Electrical Engineering, National Chung Cheng University, Chiayi City, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2021 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
PDF file
TLT. Le
T. Le
BPBaolong Nguyen Phung
Baolong Nguyen Phung
Microgrids have become more and more popular their usefulness as a renewable energy resource has been recognized. The core ability and promise of microgrids is addressing the environmental concerns due to climate change that have been growing during recent years. The innovation of microgrids is that they are designed to operate either in island mode or interconnected with the main grid system. However, when the microgrid operates in islanded mode, faults may occur which can cause system collapse or even blackout. Load curtailment schemes can be utilized to decrease the quantity of associated load to a level that can be securely supported by accessible generation in isolated mode. The main goal of this research is to evaluate the optimal amount of shedding power considering sustainable power sources, with the help of primary and secondary adjustments of the generator to restore the frequency to the allowed range. Particle Swarm Optimization algorithm is applied in this paper to determine the distributed shedding power on each demand load bus which can improve the voltage quality of the isolated microgrid system. The effectiveness of the proposed method is demonstrated through the simulation of IEEE 16- bus microgrid.

29 May 2024 in Energies
Verified
Journal Article
Open access
PDF file
BPBaolong Nguyen Phung
Baolong Nguyen Phung
Yuan-Kang WuYuan-Kang Wu
Yuan-Kang Wu
MPManh Hai PHAM
Manh Hai PHAM
This study introduced a novel control approach based on fuzzy logic control (FLC) to enhance the frequency regulation capacity of variable-speed wind turbines (VSWTs). The proposed method integrates FLC within droop and inertia control loops. Real-time measurements of the system frequency and the rate of change of frequency (ROCOF) serve as inputs to the FLC, enabling the method to improve the frequency response by VSWTs. In addition, the method employs FLC for pitch angle frequency control, optimizing reserve power for frequency regulation under varying wind speed levels. The innovative aspect of this study lies in the simultaneous application of FLC to pitch angle frequency control and droop/inertia control, leading to the enhanced frequency regulation capability of VSWTs and smoother operation across a range of wind speeds. Compared with traditional methods, the proposed approach provides a comprehensive and effective solution to the challenges associated with frequency regulation in VSWTs. Through simulations across different wind speed scenarios, the proposed control method demonstrated the best performance among various mature methods, highlighting the efficacy of the proposed method on the frequency regulation of VSWTs under different wind speeds. This study’s findings highlight the potential of the proposed FLC-based method to optimize frequency regulation and contribute to more reliable and efficient wind energy systems.

24 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
BPBaolong Nguyen Phung
Baolong Nguyen Phung
Yuan-Kang WuYuan-Kang Wu
Yuan-Kang Wu
MPManh Hai PHAM
Manh Hai PHAM
As the utilization of wind power systems continues to increase, reducing overall system inertia, there is a consequential negative impact on the power system’s ability to regulate frequency. Consequently, this study focuses on examining the fast-frequency regulation in high penetration of wind power, especially doubly fed induction generators—the most commonly installed wind turbine type, and an energy storage system installed in the wind farm. This study proposes a coordinated control of wind turbine generators and battery energy storage systems that provides fast-frequency regulation to the system while simultaneously ensuring the safety of the battery. Firstly, the fast-frequency regulation capability of the wind turbine will be studied. Secondly, primary frequency control of the battery energy storage system considering adaptive droop control based on state of charge is proposed to prevent both over-charging and over-discharging of the battery. Finally, this study proposed a coordinated fast-frequency regulation approach for the hybrid wind-storage system, which is evaluated under various wind speed scenarios. This approach involves a detailed analysis of the operational characteristics of the wind turbine generators to ensure optimal performance. The proposed method is validated through simulation using a MATLAB model of the wind-storage system, and comparative results with alternative control methods confirm the effectiveness of the proposed approach in raising the frequency nadir and avoiding the secondary frequency dip.

1 August 2022 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
TLTrong Nghia Le
Trong Nghia Le
TPTan Trieu Phung
Tan Trieu Phung
AQAnh. Huy Quyen
Anh. Huy Quyen
BPBaolong Nguyen Phung
Baolong Nguyen Phung
ANAu Ngoc Nguyen
Au Ngoc Nguyen
This paper proposes an under-frequency load shedding (UFLS) method by using the optimization technique of artificial neural network (ANN) combined with particle swarm optimization (PSO) algorithm to determine the minimum load shedding capacity. The suggested technique using a hybrid algorithm ANN-PSO focuses on 2 main goals: determine whether process shedding plan or not and the distribution of the minimum of shedding power on each demand load bus in order to restore system’s frequency back to acceptable values. In the hybrid algorithm ANN-PSO, the PSO algorithm takes responsible for searching the optimal weights in the neural network structure, which can help to optimize the network training in terms of training speed and accuracy. The distribution of shedding power at each node considering the primary control and secondary control of the generators’ unit and the phase electrical distance between the outage generators and load nodes. The effectiveness of the proposed method is experimented with multiple generators outage cases at various load levels in the IEEE-37 Bus scheme where load shedding cases are considered compared with other traditional technique.

31 August 2021 in IETE Journal of Research
Verified
Journal Article
Closed access
ANAn Thai Nguyen
An Thai Nguyen
TLTrong Nghia Le
Trong Nghia Le
HQHuy Anh Quyen
Huy Anh Quyen
MHMinh Vu Nguyen Hoang
Minh Vu Nguyen Hoang
BPBaolong Nguyen Phung
Baolong Nguyen Phung
The rapidly drop of frequency in the microgrid (MG) system when it operates under island operation has caused frequency stability problems. In case, generators and renewable energy sources cannot supply enough power to restore the frequency, the load shedding will be proceeded. This paper proposes the load shedding method based on the coordinate multiple load shedding factors when the MG system operates in island mode. This proposed method carries out an approach through two main steps. Firstly, the optimal amount of load shedding power considering renewable energy sources and the ability to adjust the primary and secondary frequencies of the generator is calculated to restore the frequency to the allowed range. Next, distributing the optimal load shedding power for each bus is based on the combination of different criteria to meet the economic and technical goals. On the technical side, this paper also considers two criteria about the voltage distance, and the voltage sensitivity index. These two criteria contribute to reducing voltage drop and improving voltage stability when the microgrid operates in island mode. From the economic perspective, it considers the load importance factor, thereby minimizing the economic losses caused by load shedding. The AHP algorithm is applied in this paper to determine the importance of loads and the importance of the different criteria when they are combined. The effectiveness of the proposed method is demonstrated through simulation of IEEE 16-bus microgrid with 6-source.

1 June 2023
Verified
Conference Paper
Closed access
Yuan-Kang WuYuan-Kang Wu
Yuan-Kang Wu
Quoc-Thang PhanQuoc-Thang Phan
Quoc-Thang Phan
BPBaolong Nguyen Phung
Baolong Nguyen Phung
Evaluation of power system reliability is significant for power system planning and operation, especially for a power system that include many renewable power resources. Appropriate methods to estimate the reliability of generation, transmission or distribution systems can help investigate the performance of smart grid developments. Several international standards such as IEEE 1366 or IEEE 762 have been released to recommend system operators or generator owners to follow the rules. In addition, North American Electric Reliability Corporation (NERC) also defined new reliability indices, such as adequate level of reliability (ALR) metrics and others. These new reliability indices consider power system resilience. This paper will summarize the existing reliability indices for power system operation, and investigate possible resilience indices for considering severity risk. Additionally, this paper provides a future trend for resilience indices.