1 August 2022 in International Journal of Electrical and Computer Engineering (IJECE)
This paper proposes an under-frequency load shedding (UFLS) method by using the optimization technique of artificial neural network (ANN) combined with particle swarm optimization (PSO) algorithm to determine the minimum load shedding capacity. The suggested technique using a hybrid algorithm ANN-PSO focuses on 2 main goals: determine whether process shedding plan or not and the distribution of the minimum of shedding power on each demand load bus in order to restore system’s frequency back to acceptable values. In the hybrid algorithm ANN-PSO, the PSO algorithm takes responsible for searching the optimal weights in the neural network structure, which can help to optimize the network training in terms of training speed and accuracy. The distribution of shedding power at each node considering the primary control and secondary control of the generators’ unit and the phase electrical distance between the outage generators and load nodes. The effectiveness of the proposed method is experimented with multiple generators outage cases at various load levels in the IEEE-37 Bus scheme where load shedding cases are considered compared with other traditional technique.
31 August 2021 in IETE Journal of Research
The rapidly drop of frequency in the microgrid (MG) system when it operates under island operation has caused frequency stability problems. In case, generators and renewable energy sources cannot supply enough power to restore the frequency, the load shedding will be proceeded. This paper proposes the load shedding method based on the coordinate multiple load shedding factors when the MG system operates in island mode. This proposed method carries out an approach through two main steps. Firstly, the optimal amount of load shedding power considering renewable energy sources and the ability to adjust the primary and secondary frequencies of the generator is calculated to restore the frequency to the allowed range. Next, distributing the optimal load shedding power for each bus is based on the combination of different criteria to meet the economic and technical goals. On the technical side, this paper also considers two criteria about the voltage distance, and the voltage sensitivity index. These two criteria contribute to reducing voltage drop and improving voltage stability when the microgrid operates in island mode. From the economic perspective, it considers the load importance factor, thereby minimizing the economic losses caused by load shedding. The AHP algorithm is applied in this paper to determine the importance of loads and the importance of the different criteria when they are combined. The effectiveness of the proposed method is demonstrated through simulation of IEEE 16-bus microgrid with 6-source.
14 October 2021 in Mathematical Problems in Engineering
This paper shows an analytic hierarchy process (AHP) algorithm-based approach for load shedding based on the coordination of the load importance factor (LIF), the reciprocal phase angle sensitivity (RPAS), and the voltage electrical distance (VED) to rank the load buses. This problem is important from a power system point of view, and the AHP method is able to support the decision-making process in a simple and intuitive way in a three-criterion environment. This satisfies the multicriteria decision-making to meet economic-technical aspects. The ranking and distributed shedding power at each demand load bus are based on this combined weight. The smaller overall weights of the load buses show the lesser importance of the load bus, the smaller reciprocal phase angle sensitivity, and the closer voltage electrical distance. Therefore, these load buses cut a larger amount of capacity, and vice versa. By considering the generator control, the load shedding consists of the primary and secondary control features of the generators to minimize the load shedding capacity and restore the system frequency value back to the allowable range. The efficiency of the suggested load-shedding scheme was verified via the comparison with the under-frequency load shedding (UFLS). The latter result is that the load shedding power of the suggested approach is 22.64% lower than the UFLS method. The case studies are experienced on the IEEE 9-generator; the 37-bus system has proven its effectiveness.
4 March 2019 in IETE Journal of Research
A large oscillation of power system caused by faults must be quickly treated so that the opportunity driving power system into re-stability state can be easier. Necessity is to select a compact data-set that is the representative of all data-sets with the aim of reducing computing costs, reducing computer memory, and improving classification accuracy. The K-means (KM) algorithm is the most commonly used clustering algorithm because it can be easily implemented and is the most effective one in terms of the execution time on large data size. The key problem of KM is that it is sensitive to initial center and may converge to a local optimization. In this paper, we proposed the use of Hybrid K-means (HKM) data clustering algorithm that can avoid being trapped in a local optimal solution. The HKM was applied with the aim of reducing data space. We also proposed a process data clustering applied to classify the problem of dynamic stability in power system. The K-Nearest Neighbor (K-NN) was chosen as the classifier. The K-NN participated in the evaluating classification accuracy stage. The study was done on IEEE 39-bus. The results showed that the proposed algorithm achieved effective data size reduction and high accuracy classification.
28 February 2022 in Journal of Technical Education Science
This paper proposes a method of ranking load in Microgird system based on the calculation of priority weights on the continuity of power supply of the loads. The proposed method applies the covariance matrix of the criterion layer to determine values of each criterion. The fuzzy preference relation matrix is used to replace the pairwise comparison matrix of the scheme layer. The weight of the criterion layer and the scheme layer are combined to get the final weights of each load bus. This solves the problem of consistency factor when evaluating loads from experts and Microgrid system operators. The calculation of priority weighting on the continuity of power supply for loads supports system operators to be proactive in planning load shedding or load shedding due to system failures, thereby minimizing damage to the system and electricity customers. The proposed method is calculated on the diagram of the IEEE 16 bus Microgrid system with six sources and eight loads.