Tan Trieu Phung

Tan Trieu Phung

Auto-generated profile, based on publicly available information

Tan Trieu Phung

Cao Thang Technical College

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2022 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
TLTrong Nghia Le
Trong Nghia Le
TPTan Trieu Phung
Tan Trieu Phung
AQAnh. Huy Quyen
Anh. Huy Quyen
BPBaolong Nguyen Phung
Baolong Nguyen Phung
ANAu Ngoc Nguyen
Au Ngoc Nguyen
This paper proposes an under-frequency load shedding (UFLS) method by using the optimization technique of artificial neural network (ANN) combined with particle swarm optimization (PSO) algorithm to determine the minimum load shedding capacity. The suggested technique using a hybrid algorithm ANN-PSO focuses on 2 main goals: determine whether process shedding plan or not and the distribution of the minimum of shedding power on each demand load bus in order to restore system’s frequency back to acceptable values. In the hybrid algorithm ANN-PSO, the PSO algorithm takes responsible for searching the optimal weights in the neural network structure, which can help to optimize the network training in terms of training speed and accuracy. The distribution of shedding power at each node considering the primary control and secondary control of the generators’ unit and the phase electrical distance between the outage generators and load nodes. The effectiveness of the proposed method is experimented with multiple generators outage cases at various load levels in the IEEE-37 Bus scheme where load shedding cases are considered compared with other traditional technique.

1 January 2023 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
TLTrong Nghia Le
Trong Nghia Le
HNHoang Minh Vu Nguyen
Hoang Minh Vu Nguyen
TNThai An Nguyen
Thai An Nguyen
TPTrieu Tan Phung
Trieu Tan Phung
THThi Thu Hien Huynh
Thi Thu Hien Huynh
QNQuang Tien Nguyen
Quang Tien Nguyen
This paper proposes a load shedding model for the island microgrid based on the ranking of loads and the power stability index (PSI). Loads are ranked based on the improved analytic hierarchy process (AHP) algorithm. Real‐time measurement systems have the function of collecting data for very important, important, and less‐important loads at each bus load. From this data, the improved AHP method is applied to rank the loads. The advantage of this method is that the subjectivity is eliminated and not depending on the expertise of the system operator when implementing the traditional AHP method. Besides, the minimum amount of load shedding power is calculated, taking into account both primary and secondary control methods. The objective is to minimize the impact on power consumers and ensure that the frequency returns to an acceptable range. In addition, when implementing load shedding, voltage quality, and stability are considered. The PSI serves as a crucial parameter for assessing the voltage stability of microgrid buses. This index is combined with load ranking weights to obtain combined weights for the load shedding plan. Consequently, the proposed load shedding plan prioritizes minimizing damage to customers, improving voltage quality and stability, and ensuring frequency is within permissible limits. The 16‐bus microgrid system is applied to compare with traditional methods and to prove the efficiency of the suggested technique.

1 November 2018
Verified
Conference Paper
Closed access
TLTrong Nghia Le
Trong Nghia Le
HQHuy Anh Quyen
Huy Anh Quyen
TPThi Thanh Binh Phan
Thi Thanh Binh Phan
NNNgoc Au Nguyen
Ngoc Au Nguyen
TTTan Phung Trieu
Tan Phung Trieu
When there is a large power imbalance, the frequency of the power system will be declined lower than the allowable value. Therefore, maintaining the frequency within the allowable value is essential. In the case of an emergency control such as a large generator trip, an effective load shedding plan is required to avoid frequency dropping and blackout. This paper introduces a new method for determining the location of the load shedding by using the phase angle sensitivity of two buses. Load shedding is based on the calculation sensitivity from the loads to the generator outage location. The shorter the loads have sensitivity; the larger capacity loads will shed. Experiment results showed the amount of load shedding is lower, the recovery time of frequency and rotor angle are faster than the conventional load shedding.

29 January 2022 in International Journal of Applied Science
Verified
Journal Article
Open access
PDF file
HQHuy Anh Quyen
Huy Anh Quyen
TTTan Phung Trieu
Tan Phung Trieu
TLTrong Nghia Le
Trong Nghia Le
TNThai An Nguyen
Thai An Nguyen
THThi Ngoc Thuong Huynh
Thi Ngoc Thuong Huynh
This paper proposes a new load shedding method based on the application of intelligent algorithms, the process of calculating and load shedding is carried out in two stages. Stage-1 uses a backpropagation neural network to classify faults in the system, thereby determining whether or not to shed the load in that particular case. Stage-2 uses an artificial neural network combined with an ant colony algorithm (ANN-ACO) to determine a load shedding strategy. The AHP algorithm is applied to propose load shedding strategies based on ranking the importance of loads in the system. The proposed method in the article helps to solve the integrated problem of load shedding, classifying the fault to determine whether or not to shedding the load and proposing a correct strategy for shedding the load. The IEEE 25-bus 8-generator power system is used to simulate and test the effectiveness of the proposed method, the results show that the frequency of recovery is good in the allowable range.

6 June 2022 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
PDF file
QLQ. T. Le
Q. T. Le
HQH. A. Quyen
H. A. Quyen
TLTrong Nghia Le
Trong Nghia Le
TPT. T. Phung
T. T. Phung
HPH. H. Pham
H. H. Pham
The existing research on lightning protection focuses on risk assessment or equipment selection. There has not been any thorough research about lightning protection including risk assessment for a building in order to identify the risks when selecting lightning protection equipment according to technical requirements and cost optimization. The objective of the current paper is to propose a new risk computational method of damages by lightning for a Television and Radio Station (TRS). The new computational method consists of nine steps for identifying two risk indices, human life loss (R1) and service loss (R2). If the value of R1 is higher than the regulatory limit value RT1 and the value of R2 is higher than the regulatory limit value RT2, the damage risks due to lightning are very serious. Therefore, the TRS is necessary to select lightning protection solutions to reduce these risks. In addition, the paper proposes a six-step procedure for selecting and testing surge protective devices. The proposed calculations are then applied to a real TRS in Vietnam, and some testing results are simulated in Matlab-Simulink.

11 September 2020
Verified
Conference Paper
Closed access
PDF file
TPTrieu V. Phung
Trieu V. Phung
VTVassilios Tzouanas
Vassilios Tzouanas