Ana Bohorquez

Dr. Ana Bohorquez

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2011 in ACS Nano
Verified
Journal Article
Closed access
MCMar Creixell
Mar Creixell
ABAna Bohorquez
Ana Bohorquez
MTMadeline Torres-Lugo
Madeline Torres-Lugo
CRCarlos Rinaldi
Carlos Rinaldi

9 October 2013 in International Journal of Hyperthermia
Verified
Journal Article
Closed access
BKBettina Kozissnik
Bettina Kozissnik
ABAna Bohorquez
Ana Bohorquez
JDJon Dobson
Jon Dobson
CRCarlos Rinaldi
Carlos Rinaldi
Though the concepts of magnetic fluid hyperthermia (MFH) were originally proposed over 50 years ago, the technique has yet to be successfully translated into routine clinical application. Significant challenges must be addressed if the field is to progress and realise its potential as an option for treatment of diseases such as cancer. These challenges include determining the optimum fields and frequencies that maximise the effectiveness of MFH without significant detrimental off-target effects on healthy tissue, achieving sufficient concentrations of magnetic nanoparticles (MNPs) within the target tumour, and developing a better mechanistic understanding of MNP-mediated energy deposition and its effects on cells and tissue. On the other hand, emerging experimental evidence indicates that local thermal effects indeed occur in the vicinity of energy-dissipating MNPs. These findings point to the opportunity of engineering MNPs for the selective destruction of cells and/or intracellular structures without the need for a macroscopic tissue temperature rise, in what we here call magnetically mediated energy delivery (MagMED).

21 August 2015 in Chemistry of Materials
Verified
Journal Article
Open access
EVErika C. Vreeland
Erika C. Vreeland
JWJohn Watt
John Watt
GSGretchen B. Schober
Gretchen B. Schober
BHBradley G. Hance
Bradley G. Hance
MAMariah J. Austin
Mariah J. Austin
DHDale L. Huber
Dale L. Huber
The synthesis of well-defined nanoparticle materials has been an area of intense investigation, but size control in nanoparticle syntheses is largely empirical. Here, we introduce a general method for fine size control in the synthesis of nanoparticles by establishing steady state growth conditions through the continuous, controlled addition of precursor, leading to a uniform rate of particle growth. This approach, which we term the “extended LaMer mechanism” allows for reproducibility in particle size from batch to batch as well as the ability to predict nanoparticle size by monitoring the early stages of growth. We have demonstrated this method by applying it to a challenging synthetic system: magnetite nanoparticles. To facilitate this reaction, we have developed a reproducible method for synthesizing an iron oleate precursor that can be used without purification. We then show how such fine size control affects the performance of magnetite nanoparticles in magnetic hyperthermia.

1 November 2015 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
FMFernando Mérida
Fernando Mérida
ACAndreina Chiu-Lam
Andreina Chiu-Lam
ABAna Bohorquez
Ana Bohorquez
LMLorena Maldonado-Camargo
Lorena Maldonado-Camargo
MHMaria-Eglee Perez Hernandez
Maria-Eglee Perez Hernandez
CRCarlos Rinaldi
Carlos Rinaldi

21 September 2020 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
PDF file
Josephine Esquivel-UpshawJosephine Esquivel-Upshaw
Josephine Esquivel-Upshaw
Shu-Min HsuShu-Min Hsu
Shu-Min Hsu
ABAna Bohorquez
Ana Bohorquez
NANader Abdulhameed
Nader Abdulhameed
GSGary W. Scheiffele
Gary W. Scheiffele
FRFan Ren
Fan Ren
Objectives: To test the hypotheses that (a) the chairside/handheld dental scanner combined with a metrology software will measure clinical wear in vivo in agreement with measurements from X‐ray computed microtomography and; (b) polished monolithic zirconia does not cause accelerated wear of opposing enamel.Materials and methods: Thirty single crowns were randomized to receive a monolithic zirconia or metal‐ceramic crown. Two non‐restored opposing teeth in the same quadrants were identified to serve as enamel controls. After cementation, quadrants were scanned using an intraoral dental scanner. Patients were recalled at 6‐months and 1‐year for re‐scanning. Scanned images were compared using a metrology software to determine maximum vertical wear of teeth. The accuracy of the scanning measurements from this new method was compared with X‐ray computed microtomography (micro‐CT) measurements. Statistical analysis was performed using Mann–Whitney U test to determine significant differences between wear of enamel against zirconia, metal‐ceramic or enamel. Linear regression analysis determined agreement between measurements obtained using intraoral scanning and micro‐CT.Results: Regression analysis demonstrated that there is a quantitative agreement between depth and volume measurements produced using intraoral scanning and the micro‐CT methodologies. There was no significant difference between the wear of enamel against polished monolithic zirconia crowns and enamel against enamel.Conclusions: Intraoral scanning combined with a matching software can accurately quantify clinical wear to verify that monolithic zirconia exhibited comparable wear of enamel compared with metal‐ceramic crowns and control enamel. Agreement between the intraoral scanner and the micro‐CT was 99.8%. Clinical Trials.gov NCT02289781.

9 December 2013 in Particle & Particle Systems Characterization
Verified
Journal Article
Closed access
PDF file
ABAna Bohorquez
Ana Bohorquez
CRCarlos Rinaldi
Carlos Rinaldi