Alberto Bandini

Dr. Alberto Bandini

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2024 in Energies
Verified
Journal Article
Open access
PDF file
ABAlberto Bandini
Alberto Bandini
Alessio CascinoAlessio Cascino
Alessio Cascino
Enrico MeliEnrico Meli
Enrico Meli
LPLorenzo Pinelli
Lorenzo Pinelli
Michele MarconciniMichele Marconcini
Michele Marconcini
When it comes to modern design of turbomachinery, one of the most critical objectives is to achieve higher efficiency and performance by reducing weight, fuel consumption, and noise emissions. This implies the need for reducing the mass and number of the components, by designing thinner, lighter, and more loaded blades. These choices may lead to mechanical issues caused by the fluid–structure interaction, such as flutter and forced response. Due to the periodic aerodynamic loading in rotating components, preventing or predicting resonances is essential to avoid or limit the dangerous vibration of the blades; thus, simulation methods are crucial to study such conditions during the machine design. The purpose of this paper is to assess a numerical approach based on a topology optimization method for the innovative design of a compressor rotor. A fluid-structural optimization process has been applied to a rotor blisk which belongs to a one-and-a-half-stage aeronautical compressor including static and dynamic loads coming from blade rotation and fluid flow interaction. The fluid forcing is computed by some CFD TRAF code, and it is processed via time and space discrete Fourier transform to extract the pressure fluctuation components in a cyclic-symmetry environment. Finally, a topological optimization of the disk is performed, and the encouraging results are presented and discussed. The remarkable mass reduction in the component (≈32%), the mode-shape frequency shift from a fluid forcing frequency, and an overall relevant reduction in the dynamic response around Campbell’s crossing confirm the efficacy of the presented methodology.

11 December 2024 in Journal of Turbomachinery
Verified
Journal Article
Closed access
PDF file
ABAlberto Bandini
Alberto Bandini
CBClaudio Bettini
Claudio Bettini
LPLorenzo Peruzzi
Lorenzo Peruzzi
MCMauro Carretta
Mauro Carretta
CCClaudio Canelli
Claudio Canelli
AAAndrea Arnone
Andrea Arnone

10 June 2016 in EP Europace
Verified
Journal Article
Open access
PDF file
Mauro BiffiMauro Biffi
Mauro Biffi
MSMatteo Santamaria
Matteo Santamaria
DPDomenico Potenza
Domenico Potenza
FZFrancesco Zanon
Francesco Zanon
MMMichele Manzo
Michele Manzo
MNMaria Narducci
Maria Narducci
Purpose of the study: Data from Madit-CRT showed that CRT-defibrillator (CRTD) patients (pts) who achieve ejection fraction (LVEF) normalization (>50%) have very low absolute and relative risk of Ventricular Tachyarrhythmias (VTAs) and a favorable clinical course within 2.2 years of follow-up. These pts could be considered for downgrade to CRT-pacemaker (CRTP) at the time of battery depletion if no VTAs have occurred. Method used: The DECODE Registry enrolled consecutive pts who underwent CRTD replacement from 2013 to 2015 in 36 Italian centers. At the time of replacement, clinical and echocardiographic findings were assessed and the number of appropriate therapies delivered by the replaced device or pre-implantation history of VTAs was retrieved. The occurrence of appropriate ICD therapies was measured during follow-up. Summary of results: A total of 313 pts with complete data were considered for this analysis (age 70 ± 10 years, male gender 73%, ischemic etiology 47%, NYHA class I/II at replacement 64%, mean LVEF 35 ± 10%). 197 (63%) pts had LVEF ≤35% whereas 33 (11%) pts achieved LVEF normalization. 115 (37%) pts received ≥1 appropriate ICD therapies prior to replacement and 24 (8%) had secondary prevention indication to ICD at the time of first implantation. Overall, clinical indication to ICD did not persist at replacement in 70 (22%) pts. During a median follow up of 365 [25th-75th: 315–415] days, 31 (10%) pts received an appropriate therapy (17% of pts with and 6% of pts without a previous appropriate ICD therapy, p = 0.0015). At multivariable analysis, an appropriate therapy prior to device replacement (OR 3.46, 95%CI 1.44 to 8.28; p = 0.005) and low glomerular filtration rate (OR 1.01, 95%CI 1.00 to 1.03; p = 0.038) were independent predictors of appropriate ICD therapy within 12 months follow-up. Both LVEF normalization and the persistence of ICD indication were not associated to the occurrence of VTAs after ICD replacement. Conclusion: Clinical indication to ICD does not persist in approximately 22% of CRTD pts who outlive their first device and about 11% of pts achieved LVEF normalization. Although these pts seem at lower risk and could be considered for downgrading to CRTP, our post-replacement data showed a non-negligible risk of VTAs within 12 months follow-up.