Francesco Zanon

Dr. Francesco Zanon


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2022 in European Heart Journal
Verified
Journal Article
Open access
PDF file
MJMarek Jastrzębski
Marek Jastrzębski
GKGrzegorz Kiełbasa
Grzegorz Kiełbasa
ÓCÓscar Cano
Óscar Cano
KCKarol Curila
Karol Curila
LHLuuk Heckman
Luuk Heckman
KVKevin Vernooy
Kevin Vernooy
Aims: Permanent transseptal left bundle branch area pacing (LBBAP) is a promising new pacing method for both bradyarrhythmia and heart failure indications. However, data regarding safety, feasibility and capture type are limited to relatively small, usually single centre studies. In this large multicentre international collaboration, outcomes of LBBAP were evaluated. Methods and results: This is a registry-based observational study that included patients in whom LBBAP device implantation was attempted at 14 European centres, for any indication. The study comprised 2533 patients (mean age 73.9 years, female 57.6%, heart failure 27.5%). LBBAP lead implantation success rate for bradyarrhythmia and heart failure indications was 92.4% and 82.2%, respectively. The learning curve was steepest for the initial 110 cases and plateaued after 250 cases. Independent predictors of LBBAP lead implantation failure were heart failure, broad baseline QRS and left ventricular end-diastolic diameter. The predominant LBBAP capture type was left bundle fascicular capture (69.5%), followed by left ventricular septal capture (21.5%) and proximal left bundle branch capture (9%). Capture threshold (0.77 V) and sensing (10.6 mV) were stable during mean follow-up of 6.4 months. The complication rate was 11.7%. Complications specific to the ventricular transseptal route of the pacing lead occurred in 209 patients (8.3%). Conclusions: LBBAP is feasible as a primary pacing technique for both bradyarrhythmia and heart failure indications. Success rate in heart failure patients and safety need to be improved. For wider use of LBBAP, randomized trials are necessary to assess clinical outcomes.

26 April 2018 in EP Europace
Verified
Journal Article
Closed access
PDF file
FZFrancesco Zanon
Francesco Zanon
KEKenneth A Ellenbogen
Kenneth A Ellenbogen
GDGopi Dandamudi
Gopi Dandamudi
PSParikshit S Sharma
Parikshit S Sharma
WHWeijian Huang
Weijian Huang
PVPugazhendhi Vijayaraman
Pugazhendhi Vijayaraman
Permanent cardiac pacing of the His-bundle restores and retains normal electrical activation of the ventricles. Data on His-bundle pacing (HBP) are largely limited to small single-centre reports, and clinical benefits and risks have not been systematically examined. We sought to systematically examine published studies of patients undergoing permanent HBP and quantify the benefits and risks of the therapy. PubMed, Embase, and Cochrane Library were searched for full-text articles on permanent HBP. Clinical outcomes of interest included implant success rate, procedural and lead complications, pacing thresholds, QRS duration, and ejection fraction at follow-up, and mortality. Data were extracted and summarized. Where possible, meta-analysis of aggregate data was performed. Out of 2876 articles, 26 met the inclusion criteria representing 1438 patients with an implant attempt. Average age of patients was 73 years and 62.1% were implanted due to atrioventricular block. Overall average implant success rate was 84.8% and was higher with use of catheter-delivered systems (92.1%; P < 0.001). Average pacing thresholds were 1.71 V at implant and 1.79 V at >3 months follow-up; although, pulse widths varied at testing. Average left ventricular ejection fractions (LVEFs) were 42.8% at baseline and 49.5% at follow-up. There were 43 complications observed in 907 patients across the 17 studies that reported safety information. Among 26 articles of permanent HBP, the implant success rate averaged 84.8% and LVEF improved by an average of 5.9% during follow-up. Specific reporting of our clinical outcomes of interest varied widely, highlighting the need for uniform reporting in future HBP trials.

28 March 2025 in EP Europace
Verified
Journal Article
Open access
MGMichael Glikson
Michael Glikson
HBHaran Burri
Haran Burri
AAAmr Abdin
Amr Abdin
ÓCÓscar Cano
Óscar Cano
KCkarol curila
karol curila
NVNiraj Varma
Niraj Varma
Conduction system pacing (CSP) is being increasingly adopted as a more physiological alternative to right ventricular and biventricular pacing. Since the 2021 European Society of Cardiology pacing guidelines, there has been growing evidence that this therapy is safe and effective. Furthermore, left bundle branch area pacing was not covered in these guidelines due to limited evidence at that time. This Clinical Consensus Statement provides advice on indications for CSP, taking into account the significant evolution in this domain.

16 July 2019 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
FZFrancesco Zanon
Francesco Zanon
MAMohamed Abdelrahman
Mohamed Abdelrahman
LMLina Marcantoni
Lina Marcantoni
ANAngela Naperkowski
Angela Naperkowski
FSFaiz A Subzposh
Faiz A Subzposh
PVPugazhendhi Vijayaraman
Pugazhendhi Vijayaraman

13 January 2006 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
FZFrancesco Zanon
Francesco Zanon
EBEnrico Baracca
Enrico Baracca
SASilvio Aggio
Silvio Aggio
GPGianni Pastore
Gianni Pastore
GBGraziano Boaretto
Graziano Boaretto
PZPietro Zonzin
Pietro Zonzin

1 May 2015 in Heart Rhythm
Verified
Journal Article
Open access
FZFrancesco Zanon
Francesco Zanon
EBEnrico Baracca
Enrico Baracca
GPGianni Pastore
Gianni Pastore
LMLina Marcantoni
Lina Marcantoni
CFChiara Fraccaro
Chiara Fraccaro
FPFrits W. Prinzen
Frits W. Prinzen
Response to cardiac resynchronization therapy (CRT) remains challenging. Pacing from multiple sites of the left ventricle (LV) has shown promising results. The purpose of this study was to systematically compare the acute hemodynamic effects of multipoint pacing (MPP) by means of a quadripolar lead with conventional biventricular (BiV) pacing. Twenty-nine patients (23 men; mean age 72 ± 12 years; LV ejection fraction 29% ± 7%; 15 with ischemic cardiomyopathy, 17 with left bundle branch block; mean QRS 183 ± 23 ms) underwent CRT implantation. Per patient, 3.2 ± 1.2 different veins and 6.3 ± 2.4 pacing sites were tested. LV electrical delay (Q-LV) was measured at each location, along with the increase in LV dP/dtmax (maximum rate of rise of LV pressure) obtained by BiV and MPP. The effect of MPP, by means of simultaneous pacing from distal and proximal dipoles, was investigated at all available sites. Overall, 3.2 ± 1.2 different MPP measurements were collected per patient. When all sites were considered, LV dP/dtmax increased from 951 ± 193 mm Hg/s at baseline to 1144 ± 255 and 1178 ± 259 mm Hg/s on BiV and MPP, respectively. When the best site was considered, LV dP/dtmax increased from a baseline value of 942 ± 202 mm Hg/s to 1200 ± 267 mm Hg/s (BiV) and 1231 ± 267 mm Hg/s (MPP). The mean QRS duration at any site during MPP and conventional CRT was 171 ± 18 and 175 ± 16 ms (P = .003), respectively. Compared with BiV pacing at any LV site, MPP yielded a small but consistent increase in hemodynamic response. A correlation between the increase in hemodynamics and Q-LV on MPP was observed for all measurements, including those taken at the best and worst sites. The MPP-induced improvement in contractility was associated with significantly greater narrowing of the QRS complex than conventional BiV pacing.