Microgrids are a new concept for future energy distribution systems that enable renewable energy integration and improved energy management capability. Microgrids consist of multiple distributed generators (DGs) that are usually integrated via power electronic inverters. In order to enhance power quality and power distribution reliability, microgrids need to operate in both grid-connected and island modes. Consequently, microgrids can suffer performance degradation as the operating conditions vary due to abrupt mode changes and variations in bus voltages and system frequency. This paper presents controller design and optimization methods to stably coordinate multiple inverter-interfaced DGs and to robustly control individual interface inverters against voltage and frequency disturbances. Droop-control concepts are used as system-level multiple DG coordination controllers, and control theory is applied to device-level inverter controllers. Optimal control parameters are obtained by particle-swarm-optimization algorithms, and the control performance is verified via simulation studies.
This paper presents a method to seek the PI controller parameters of a PMSG wind turbine to improve control performance. Since operating conditions vary with the wind speed, therefore the PI controller parameters should be determined as a function of the wind speed. Small-signal modeling of a PMSG WT is implemented to analyze the stability under various operating conditions and with eigenvalues obtained from the small-signal model of the PMSG WT, which are coordinated by adjusting the PI controller parameters. The parameters to be tuned are chosen by investigating participation factors of state variables, which simplifies the problem by reducing the number of parameters to be tuned. The process of adjusting these PI controller parameters is carried out using particle swarm optimization (PSO). To characterize the improvements in the control method due to the PSO method of tuning the PI controller parameters, the PMSG WT is modeled using the MATLAB/SimPowerSystems libraries with the obtained PI controller parameters.
14 February 2018 in IEEE Transactions on Power Delivery
A new control method for a line-commutated converter-based (LCC) high-voltage direct-current (HVDC) system is presented and compared to a conventional strategy. In the proposed method, both the DC voltage and current of an LCC HVDC system are regulated to increase the short-term operating margin of DC power transfer and improve transient responses to DC power references. In particular, an increased operating margin of DC power transfer is achieved via the DC voltage regulation method. To verify the effectiveness of the proposed method, a state space model of an LCC HVDC system is developed considering DC voltage and current references as input variables and analyzed for various values of the DC line inductance and converter controller gains. The state space model can be used for time-efficient analyses of the dynamic characteristics of an LCC HVDC system. Simulation case studies are performed using MATLAB, where the state space model of the Jeju-Haenam HVDC system is implemented as a test case and compared to its comprehensive PSCAD model. The case study results suggest that the proposed method increases the short-term operating margin and speeds up the transient response of the HVDC system. Therefore, it will effectively improve real-time grid frequency regulation.
17 January 2020 in IEEE Transactions on Energy Conversion
We propose a new local controller to determine the active power reference for an interlinking converter (IC) of an islanded hybrid ac/dc microgrid (IHMG). The main objective of the proposed method is to improve the accuracy of global power sharing (GPS) between distributed generators throughout an IHMG to enhance the reliability and stability. Based on our analysis of the required active power of ICs for GPS, a local IC controller is proposed to enable parallel IC operation and improve GPS. The effects of the proposed controller on the system stability and GPS accuracy are also analyzed using a small-signal model. Furthermore, we provide guidelines on how to determine an appropriate control parameter for the proposed controller based on the desired GPS accuracy and the stability margin. Finally, the proposed method is verified by Simulink/MATLAB and hardware-in-the-loop experimental platform.
6 January 2020 in IEEE Transactions on Power Systems
In this paper, a new control method for a line-commutated converter-based (LCC) high-voltage direct current (HVDC) system to support the frequency and AC voltage was proposed. For coordinated control of the inverter and rectifier, droop-based controllers are adopted for the outer loop of conventional controllers, and DC voltage is used to transfer the frequency information so that communication is not required. A method to determine the droop constants of the proposed controller is presented to emulate the conventional f/P droop characteristic and suppress the AC voltage fluctuations. Furthermore, a small-signal state-space model of the LCC HVDC system with the proposed scheme is derived, and root locus analysis is carried out to evaluate its stability. The effects of the proposed method are verified based on case studies, using the well-known CIGRE BENCHMARK model. The advantages of the proposed method can be summarized as follows: 1) system reliability is enhanced because there is no risk of communication failure during frequency information transfer and 2) voltage stability at the inverter side is enhanced as AC voltage fluctuation during frequency support is minimized.
Variable-speed wind turbines (VSWTs) typically use a maximum power-point tracking (MPPT) method to optimize wind-energy acquisition. MPPT can be implemented by regulating the rotor speed or by adjusting the active power. The former, termed speed-control mode (SCM), employs a speed controller to regulate the rotor, while the latter, termed power-control mode (PCM), uses an active power controller to optimize the power. They are fundamentally equivalent; however, since they use a different controller at the outer control loop of the machine-side converter (MSC) controller, the time dependence of the control system differs depending on whether SCM or PCM is used. We have compared and analyzed the power quality and the power coefficient when these two different control modes were used in fluctuating wind speeds through computer simulations. The contrast between the two methods was larger when the wind-speed fluctuations were greater. Furthermore, we found that SCM was preferable to PCM in terms of the power coefficient, but PCM was superior in terms of power quality and system stability.