Jose Alejandro Colmenarez

Dr. Jose Alejandro Colmenarez

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
CRCez R
Cez R
JCJose Alejandro Colmenarez
Jose Alejandro Colmenarez
KSKourosh Shahraki
Kourosh Shahraki
PDPENGFEI DONG
PENGFEI DONG
Linxia GuLinxia Gu
Linxia Gu
Donny W. SuhDonny W. Suh
Donny W. Suh
Purpose: Pickleball, the fastest-growing sport in the United States, has seen a rapid increase in participation across all age groups, particularly among older adults. However, the sport introduces specific risks for ocular injuries due to the unique dynamics of gameplay and the physical properties of the pickleball. This study aims to explore the mechanisms of pickleball-related eye injuries, utilizing finite element modeling (FEM) to simulate ocular trauma and better understand injury mechanisms. Methods: A multi-modal approach was employed to investigate pickleball-related ocular injuries. Finite element modeling (FEM) was used to simulate blunt trauma to the eye caused by a pickleball. The FEM incorporated detailed anatomical models of the periorbital structures, cornea, sclera, and vitreous body, using hyperelastic material properties derived from experimental data. The simulations evaluated various impact scenarios, including changes in ball velocity, angle of impact, and material stiffness, to determine the stress distribution, peak strain, and deformation in ocular structures. The FEM outputs were correlated with clinical findings to validate the injury mechanisms. Results: The FE analysis revealed that the rigid, hard-plastic construction of a pickleball results in concentrated stress and strain transfer to ocular structures upon impact. At velocities exceeding 30 mph, simulations showed significant corneal deformation, with peak stresses localized at the limbus and anterior sclera. Moreover, our results show a significant stress applied to lens zonules (as high as 0.35 MPa), leading to potential lens dislocation. Posterior segment deformation was also observed, with high strain levels in the retina and vitreous, consistent with clinical observations of retinal tears and vitreous hemorrhage. Validation against reported injuries confirmed the model’s accuracy in predicting both mild injuries (e.g., corneal abrasions) and severe outcomes (e.g., hyphema, globe rupture). Conclusions: Finite element analysis provides critical insights into the biomechanical mechanisms underlying pickleball-related ocular injuries. The findings underscore the need for preventive measures, particularly among older adults, who exhibit age-related vulnerabilities. Education on the importance of wearing protective eyewear and optimizing game rules to minimize high-risk scenarios, such as close-range volleys, is essential. Further refinement of the FEM, including parametric studies and integration of protective eyewear, can guide the development of safety standards and reduce the socio-economic burden of these injuries.

9 October 2023 in Journal of Engineering and Science in Medical Diagnostics and Therapy
Verified
Journal Article
Closed access
PDF file
JCJose Alejandro Colmenarez
Jose Alejandro Colmenarez
YZYingnan Zhai
Yingnan Zhai
Valentina Ochoa MendozaValentina Ochoa Mendoza
Valentina Ochoa Mendoza
PDPENGFEI DONG
PENGFEI DONG
KNKenia Pedrosa Nunes
Kenia Pedrosa Nunes
Linxia GuLinxia Gu
Linxia Gu

3 January 2025 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
JCJose Alejandro Colmenarez
Jose Alejandro Colmenarez
PDPENGFEI DONG
PENGFEI DONG
JLJuhwan Lee
Juhwan Lee
DWDavid Wilson
David Wilson
Linxia GuLinxia Gu
Linxia Gu
Lipid-rich atheromas are linked to plaque rupture in stented atherosclerotic arteries. While fibrous cap thickness is acknowledged as a critical indicator of vulnerability, it is likely that other morphological features also exert influence. However, detailed quantifications of their contributions and intertwined effects in stenting are lacking. Therefore, our goal is to assess the impact of plaque characteristics on the fibrous cap stress and elucidate their underlying mechanisms. We analyzed the stent deployment over a 3D patient-specific coronary artery reconstructed from intravascular optical coherence tomography (IVOCT) through finite element methods. Additionally, we performed sensitivity analysis on 78,000 distinct plaque geometries of two-dimensional arteries for verification. Results from the 3D patient-specific model indicate strong correlations between maximum fibrous cap stress and lipid arc (r=0.769), area stenosis (r=0.550), and lumen curvature (r=0.642). Plaques with lipid arcs > 60°, area stenosis > 75%, and lumen curvatures > 5 mm-1 are at increased rupture risk. While we observed a rise in stress with lipid core thickness, it was less representative than other features. Fibrous cap thickness showed a poor correlation, with the sensitivity analysis revealing its significance only when high stretches are induced by other features, likely due to its J-shaped stress-stretch response. Contrary to physiological pressure, the stent expansion generates unique vulnerable features as the stent load-transferring characteristics modify the plaque?s response. This study is expected to prompt further clinical investigations of other morphological features for predicting plaque rupture in stenting.

21 October 2025 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
JCJose Alejandro Colmenarez
Jose Alejandro Colmenarez
PDPengfei Dong
Pengfei Dong
XLXianqi Li
Xianqi Li
Linxia GuLinxia Gu
Linxia Gu