Jérôme ADRIEN

Dr. Jérôme ADRIEN

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2010 in Experimental Mechanics
Verified
Journal Article
Closed access
PDF file
JBJ. -Y. Buffiere
J. -Y. Buffiere
Eric MaireEric Maire
Eric Maire
JAJérôme ADRIEN
Jérôme ADRIEN
JMJ. -P. Masse
J. -P. Masse
EBE. Boller
E. Boller

18 December 2015 in Plant Methods
Verified
Journal Article
Open access
PDF file
RDROUSSEAU David
ROUSSEAU David
TWThomas Widiez
Thomas Widiez
STSylvaine Di Tommaso
Sylvaine Di Tommaso
HRHugo Rositi
Hugo Rositi
JAJérôme ADRIEN
Jérôme ADRIEN
PRPeter Rogowsky
Peter Rogowsky
Despite increasing demand, imaging the internal structure of plant organs or tissues without the use of transgenic lines expressing fluorescent proteins remains a challenge. Techniques such as magnetic resonance imaging, optical projection tomography or X-ray absorption tomography have been used with various success, depending on the size and physical properties of the biological material. X-ray in-line phase tomography was applied for the imaging of internal structures of maize seeds at early stages of development, when the cells are metabolically fully active and water is the main cell content. This 3D imaging technique with histology-like spatial resolution is demonstrated to reveal the anatomy of seed compartments with unequalled contrast by comparison with X-ray absorption tomography. An associated image processing pipeline allowed to quantitatively segment in 3D the four compartments of the seed (embryo, endosperm, nucellus and pericarp) from 7 to 21 days after pollination. This work constitutes an innovative quantitative use of X-ray in-line phase tomography as a non-destructive fast method to perform virtual histology and extends the developmental stages accessible by this technique which had previously been applied in seed biology to more mature samples.

24 August 2010 in Experimental Mechanics
Verified
Journal Article
Closed access
PDF file
NLN. Limodin
N. Limodin
JRJulien Réthoré
Julien Réthoré
JAJérôme ADRIEN
Jérôme ADRIEN
JBJ.-Y. Buffière
J.-Y. Buffière
FHFrancois Hild
Francois Hild
SRStéphane ROUX
Stéphane ROUX

6 February 2018 in Materials
Verified
Journal Article
Open access
PDF file
ALALETHEA LIENS
ALETHEA LIENS
AEAurélien Etiemble
Aurélien Etiemble
PRPascaline Rivory
Pascaline Rivory
SBSandra Balvay
Sandra Balvay
JPJean-Marc PELLETIER
Jean-Marc PELLETIER
Jérôme ChevalierJérôme Chevalier
Jérôme Chevalier
Ti40Zr10Cu36Pd14 Bulk Metallic Glass (BMG) appears very attractive for future biomedical applications thanks to its high glass forming ability, the absence of toxic elements such as Ni, Al or Be and its good mechanical properties. For the first time, a complete and exhaustive characterization of a unique batch of this glassy alloy was performed, together with ISO standard mechanical tests on machined implant-abutment assemblies. The results were compared to the benchmark Ti-6Al-4V ELI (Extra-Low-Interstitial) to assess its potential in dental implantology. The thermal stability, corrosion and sterilization resistance, cytocompatibility and mechanical properties were measured on samples with a simple geometry, but also on implant-abutment assemblies’ prototypes. Results show that the glassy alloy exhibits a quite high thermal stability, with a temperature range of 38 °C between the glass transition and crystallization, a compressive strength of 2 GPa, a certain plastic deformation (0.7%), a hardness of 5.5 GPa and a toughness of 56 MPa.√m. Moreover, the alloy shows a relatively lower Young’s modulus (96 GPa) than the Ti-6Al-4V alloy (110–115 GPa), which is beneficial to limit bone stress shielding. The BMG shows a satisfactory cytocompatibility, a high resistance to sterilization and a good corrosion resistance (corrosion potential of −0.07 V/SCE and corrosion current density of 6.0 nA/cm2), which may ensure its use as a biomaterial. Tests on dental implants reveal a load to failure 1.5-times higher than that of Ti-6Al-4V and a comparable fatigue limit. Moreover, implants could be machined and sandblasted by methods usually conducted for titanium implants, without significant degradation of their amorphous nature. All these properties place this metallic glass among a promising class of materials for mechanically-challenging applications such as dental implants.

1 November 2014 in Materials Characterization
Verified
Journal Article
Closed access
AKA. King
A. King
PRP. Reischig
P. Reischig
JAJérôme ADRIEN
Jérôme ADRIEN
SPS. Peetermans
S. Peetermans
WLWolfgang Ludwig
Wolfgang Ludwig

1 July 2010 in Ironmaking & Steelmaking: Processes, Products and Applications
Verified
Journal Article
Closed access
VSVolodymyr Shatokha
Volodymyr Shatokha
IKI. Korobeinikov
I. Korobeinikov
Eric MaireEric Maire
Eric Maire
Laurent GremillardLaurent Gremillard
Laurent Gremillard
JAJérôme ADRIEN
Jérôme ADRIEN