A rapid and simple thermally-solvent assisted method of bonding was introduced for poly(methyl methacrylate) (PMMA) based microfluidic substrates. The technique is a low-temperature ( ), and rapid ( ) bonding technique; in addition, only a fan-assisted oven with some paper clamps are used. Two different solvents (ethanol and isopropyl alcohol) with two different methods of cooling (one-step and three steps) were employed to determine the best solvent and method of cooling (residual stresses may be released in different cooling methods) by considering bonding strength and quality. In this bonding technique, a thin film of solvent between two PMMA sheets disperses tends to dissolve a thin film of PMMA sheet surface, then evaporate, and finally reconnect monomers of the PMMA sheets at the specific operating temperature. The operating temperature of this method comes from the coincidence of the solubility parameter graph of PMMA with the solubility parameter graph of the solvents. Different tests such as tensile strength test, deformation test, leakage tests, and surface characteristics tests were performed to find the optimum conditions for this bonding strategy. The best bonding quality and the highest bonding strength ( ) occurred when 70% isopropyl alcohol solution was employed with the one-step cooling method. Furthermore, the bonding reversibility was taken into account and critical percentages for irreversible bonding were obtained for both of the solvents and methods. This method provides a perfect bonding quality for PMMA substrates, and can be used in laboratories without needing any expensive and special instruments, because of its merits such as lower bonding time, lower-cost, and higher strength etc in comparison with the majority of other common bonding techniques.
Pd doped WO3 fibers were synthesized by electro-spinning. The sol gel method was employed to prepare peroxopolytungstic acid (P-PTA). Palladium chloride and Polyvinyl pyrrolidone (PVP) was dissolved in the sol Pd:WO3 = 10% molar ratio. The prepared sol was loaded into a syringe connected to a high voltage of 18.3 kV and electrospun fibers were collected on the alumina substrates. Scanning electron microscope (SEM), X-ray powder diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) techniques were used to analyze the crystal structure and chemical composition of the fibers after heat treatment at 500 °C. Resistance-sensing measurements exhibited a sensitivity of about 30 at 500 ppm hydrogen in air, and the response and recovery times were about 20 and 30 s, respectively, at 300 °C. Hydrogen gas sensing mechanism of the sensor was also studied.
This paper presents a sensor system to estimate wrist and elbow positions developing two wearable miniature motion sensors. The developed sensors consist of a processor, a motion sensor, which comprise a 3-D accelerometer, a 3-D gyroscope, a 3-D magnetometer, as well as a transceiver operating at industrial, scientific, and medical band frequency of 2.4 GHz. By proposing a modified complementary filter alongside employing hand kinematic problem, wrist and elbow positions for three different exercises are estimated. In order to determine the accuracy and precision of the developed system, the estimated positions are compared to an optical tracking system. The obtained results illustrate root-mean-square error (RMSE) of these two exercises for positions of x-, y-, and z-axes less than 0.4, 0.59, and 0.29 cm, respectively. Also, the RMSEs of joint angles are obtained less than 1.64° in these exercises. These results show a 11%-23% improvement for estimating these positions than Madgwick filter and prove that the proposed system can be used as an accurate position feedback for monitoring hand joint movement in rehabilitation exercises.